ND-70428 (E) CHAPTER 4
Page 35
Revision 1.0
MESSAGE FORMAT
(2) MC PBX Message
(a) Summary of format
 
(b) Data type list (see Table 4-7)
Table 4-7  MC ® PBX Data Type Explanation
Data Type Description Data Length
00 Not used —
01 ON/OFF 01
02 Station No. (STA1) 01 to 16
03 Station No. (STA2) 01 to 16
04 Tenant number/user group number 06
05 to 99 Not used —
Data field S
T
X0!A
/
BData
typeE
T
X Data
lengthData
typeData
lengthData field
 ò ò
 ò ò
 ò ò
 ò ò 

Page 42

CHAPTER 4  ND -7 0428 ( E)
M ESS AG E F ORM AT
S ta tio n  num be r/
S
te lep ho ne  num ber
 ò ò
 ò ò
 ò ò
 ò ò
S ta tio n n umb er/
S
04
te le p ho ne n um ber
 ò ò
 ò ò
 ò ò
 ò ò 

Page 43

ND-70428 (E) CHAPTER 4
Page 37
Revision 1.0
MESSAGE FORMAT
Note 1:
This information has the following meanings:
0: All MWL Off
1: MWL On for MC
2: MWL On for VMS
5: MWL Off for MC
6: MWL Off for VMS
Note 2:Table 4-8 explains the meaning of STA1 and STA2. The number of digits in the station number and the
tenant number of these stations must be the same.
Note 3:If the tenant number in the MWL control data is not used, default value of tenant number is one.
Table 4-8  MC ® PBX Data Type Explanation
STA1...

Page 44

CHAPTER 4 ND-70428 (E)
Pag e 3 8
Revision 1.0
This page is for your notes. 

Page 45

ND-70428 (E) CHAPTER 5
Page 39
Revision 1.0
CHAPTER 5 SERVICE CONDITIONS
(1) A maximum of 2 ports can be used for MCI. When 2 ports are used for MCI, note the following conditions.
• When both ports are operating normally
Transmission: Messages are transmitted from the smaller-numbered port.
Reception: Messages are received from both ports.
• When one of the ports is faulty
Transmission: Messages are transmitted from the port operating normally.
Reception: Messages are received from the port operating...

Page 46

CHAPTER 5 ND-70428 (E)
Pag e 4 0
Revision 1.0
This page is for your notes. 

Page 47

ND-70428 (E) CHAPTER 6
Page 41
Revision 1.0
CHAPTER 6 DATA ASSIGNMENT
STEP 1: ASYD - System Data 1, Index 28, Bits 0-4 Assign  a  Miscellaneous  Timer  Counter  (MTC)  used  to
calculate the message-sending Guard Timer for Message
Center. If not required, assign data “0” to these bits.
System Data 1, Index 28, Bit 5 Is Message Waiting Lamp setting from the Message Center to
be used? 0/1: No/Yes.
System Data 1, Index 29, Bits 1-7 Assign which I/O port will act as the Message Center Interface
(a maximum of...

Page 48

CHAPTER 6 ND-70428 (E)
Pag e 4 2
Revision 1.0
DATA ASSIGNMENT
STEP 4: AUCD - Whether UCD incoming call information is to be sent to a Message Center Interface or not can
be specified on a UCD group basis using the following parameter:
MCI: 0/1 (Not to be sent/To be sent to MCI)
STEP 5: ARPC - In the case of CCIS network, assign Remote Point Code (RPC) of each remote node.
CSN (Centralized Service Number): 1 (Message Center)
CNT (Remote Point Code Counter): (1-32)
RPC (Remote Point Code): (1-16383) 