ND-70428 (E) CHAPTER 4 Page 35 Revision 1.0 MESSAGE FORMAT (2) MC PBX Message (a) Summary of format (b) Data type list (see Table 4-7) Table 4-7 MC ® PBX Data Type Explanation Data Type Description Data Length 00 Not used — 01 ON/OFF 01 02 Station No. (STA1) 01 to 16 03 Station No. (STA2) 01 to 16 04 Tenant number/user group number 06 05 to 99 Not used — Data field S T X0!A / BData typeE T X Data lengthData typeData lengthData field ò ò ò ò ò ò ò ò
Page 42
CHAPTER 4 ND -7 0428 ( E) M ESS AG E F ORM AT S ta tio n num be r/ S te lep ho ne num ber ò ò ò ò ò ò ò ò S ta tio n n umb er/ S 04 te le p ho ne n um ber ò ò ò ò ò ò ò ò
Page 43
ND-70428 (E) CHAPTER 4 Page 37 Revision 1.0 MESSAGE FORMAT Note 1: This information has the following meanings: 0: All MWL Off 1: MWL On for MC 2: MWL On for VMS 5: MWL Off for MC 6: MWL Off for VMS Note 2:Table 4-8 explains the meaning of STA1 and STA2. The number of digits in the station number and the tenant number of these stations must be the same. Note 3:If the tenant number in the MWL control data is not used, default value of tenant number is one. Table 4-8 MC ® PBX Data Type Explanation STA1...
Page 45
ND-70428 (E) CHAPTER 5 Page 39 Revision 1.0 CHAPTER 5 SERVICE CONDITIONS (1) A maximum of 2 ports can be used for MCI. When 2 ports are used for MCI, note the following conditions. • When both ports are operating normally Transmission: Messages are transmitted from the smaller-numbered port. Reception: Messages are received from both ports. • When one of the ports is faulty Transmission: Messages are transmitted from the port operating normally. Reception: Messages are received from the port operating...
Page 47
ND-70428 (E) CHAPTER 6 Page 41 Revision 1.0 CHAPTER 6 DATA ASSIGNMENT STEP 1: ASYD - System Data 1, Index 28, Bits 0-4 Assign a Miscellaneous Timer Counter (MTC) used to calculate the message-sending Guard Timer for Message Center. If not required, assign data “0” to these bits. System Data 1, Index 28, Bit 5 Is Message Waiting Lamp setting from the Message Center to be used? 0/1: No/Yes. System Data 1, Index 29, Bits 1-7 Assign which I/O port will act as the Message Center Interface (a maximum of...
Page 48
CHAPTER 6 ND-70428 (E) Pag e 4 2 Revision 1.0 DATA ASSIGNMENT STEP 4: AUCD - Whether UCD incoming call information is to be sent to a Message Center Interface or not can be specified on a UCD group basis using the following parameter: MCI: 0/1 (Not to be sent/To be sent to MCI) STEP 5: ARPC - In the case of CCIS network, assign Remote Point Code (RPC) of each remote node. CSN (Centralized Service Number): 1 (Message Center) CNT (Remote Point Code Counter): (1-32) RPC (Remote Point Code): (1-16383)