NDA-24288 CHAPTER 4
Page 239
Revision 1.0
AAST
4. Data Sheet
TENANT 
NUMBER 
(TN)STATION NUMBER
(STN)
MAXIMUM
6 DIGITSLINE EQUIPMENT NUMBER (LENS)TELEHONE 
EQUIPMENT 
CLASS 
(TEC)
1 – 31ROUTE 
RESTRICTION 
CLASS 
(RSC)
0 – 15SERVICE 
FEATURE 
CLASS
 (SFC)
0 – 15ROOM CLASS 
(ROOM 
CLASS)
0 – 15ANNEX
(ANX)
0 – 3GROUND/
UNDERGROUND 
(G)
0/1FLOOR 
(FLR)
1 – 127
MG U G LV 

Page 252

CHAPTER 4 NDA-24288
Page 240
Revision 1.0
AGST
AGST:    Assignment of Guest Station Data
1. General
This command assigns and deletes Guest Room Data. 
2. Precautions
1. This command is used for the Hotel Application only.
2. The AGSN command changes the station number, and the AGCL command changes the Class data (TEC,
RSC, SFC, etc.).
3. Only Telephone Equipment Classes (TECs) 5-8, 10, and 12 may be assigned Guest station.
4. The number of digits for a station number are designated by the ASYD command,...

Page 253

NDA-24288 CHAPTER 4
Page 241
Revision 1.0
AGST
3. Data Entry Instructions
TEC
LENS
Enter the LENS
XX X XX X
                                           Level No. (0-7)
                                           Group No. (00-31)
                                           Unit No. (0-3)
                                           Module Group No. (00-31)
G
0 : Ground
1 : Underground
TENANT
NUMBER
   (TN)    STATION
  NUMBER
     (STN)
Max. 6 digitsTELEPHONE
EQUIPMENT
    CLASS
     (TEC)
      1-31...

Page 254

CHAPTER 4 NDA-24288
Page 242
Revision 1.0
AGST
4. Data Sheet
TENANT
 NUMBER
 (TN)STATION NUMBER
(STN)
MAXIMUM
6 DIGITSLINE EQUIPMENT NUMBER
 (LENS)TELEPHONE
EQUIPMENT
CLASS
 (TEC)
1 – 31ROUTE
RESTRICTION 
CLASS (RSC)
0 – 15SERVICE
FEATURE
CLASS
(SFC)
0 – 15ROOM
CLASS
(ROOM 
CLASS)
0 – 15ANNEX
(ANX)
0 – 3GROUND/
UNDER-
GROUND
(G)
0/1FLOOR
(FLR)
1 – 127
MG U G LV 

Page 255

NDA-24288 CHAPTER 4
Page 243
Revision 1.0
AASN
AASN: Assignment of Alternated Administration Station Number
1. General
This command changes a currently assigned Administration Station Number.
2. Precautions
1. This command is used for the Hotel Application only. 
2. Input a number which is not currently assigned. If a station number currently being used is to be assigned
as a new number, delete the station first via the RAST command.
3. When the “PKG CHECK” message is displayed during assignment, confirm...

Page 256

CHAPTER 4 NDA-24288
Page 244
Revision 1.0
AACL
AACL: Assignment of Administration Station Class
1. General
This command changes the data assigned to an Administration Station: Telephone Equipment Class (TEC),
Service Feature Class (SFC), Route Restriction Class (RSC), ROOM CLASS and Floor Service Data. 
2. Precautions
1. This command is used for the Hotel Application only.
2. Only Telephone Equipment Classes (TECs) 1-4, 12-15, 18-20 and 13 may be assigned via this command.
3. Floor Service Data is...

Page 257

NDA-24288 CHAPTER 4
Page 245
Revision 1.0
AACL
3. Data Entry Instructions
TEC
RSCANNEX
G
NOTE STN
SFC
TENANT
NUMBER
    (TN)  STATION
  NUMBER
     (STN)
Max. 6 digitsTELEPHONE EQUIPMENT    CLASS
      (TEC)
       1-31      ROUTE
RESTRICTION
      CLASS
       (RSC)
        0-15SERVICE
FEATURE
  CLASS
   (SFC)
    0-15ROOM
CLASS
  0-15ANNEX
 (ANX)
   0-3  
     GROUND/
UNDERGROUND
           (G)
           0/1FLOOR
 (FLR)
 1-127
112                           1                           1
1 : DP (10 pps)...

Page 258

CHAPTER 4 NDA-24288
Page 246
Revision 1.0
AGSN
AGSN:    Assignment of Alternated Guest Station Number
1. General
This command changes a currently assigned Guest Station Number.
2. Precautions
1. This command is used for the Hotel Application only.
2. Input a number which is not currently assigned. If a station number currently being used is to be assigned
as a new number, delete the station first via the RGST command.
3. When the “PKG CHECK” message is displayed during assignment, confirm the LENS...

Page 259

NDA-24288 CHAPTER 4
Page 247
Revision 1.0
AGCL
AGCL: Assignment of Guest Station Class
1. General
This command changes the data assigned to a Guest Station: Telephone Equipment Class (TEC), Service
Feature Class (SFC), Route Restriction Class (RSC), ROOM CLASS and Floor Service Data [Annex (ANX),
Ground/Underground (G), Floor (FLR)]. 
2. Precautions
1. This command is used for the Hotel Application only.
2. Only Telephone Equipment Classes (TECs) 5-8, 10 and 12 may be assigned via this command.
3. Floor...

Page 260

CHAPTER 4 NDA-24288
Page 248
Revision 1.0
AGCL
3. Data Entry Instructions
TEC
RSCANNEX
G
NOTE STN
SFC
TENANT
NUMBER
    (TN)  STATION
  NUMBER
     (STN)
Max. 6 digitsTELEPHONE EQUIPMENT    CLASS
      (TEC)
       1-31      ROUTE
RESTRICTION
      CLASS
       (RSC)
        0-15SERVICE
FEATURE
  CLASS
   (SFC)
    0-15ROOM
CLASS
  0-15ANNEX
 (ANX)
   0-3  
     GROUND/
UNDERGROUND
           (G)
           0/1FLOOR
 (FLR)
 1-127
112                           1                           1
Enter the RSC...