Page 251
NDA-24288 CHAPTER 4 Page 239 Revision 1.0 AAST 4. Data Sheet TENANT NUMBER (TN)STATION NUMBER (STN) MAXIMUM 6 DIGITSLINE EQUIPMENT NUMBER (LENS)TELEHONE EQUIPMENT CLASS (TEC) 1 – 31ROUTE RESTRICTION CLASS (RSC) 0 – 15SERVICE FEATURE CLASS (SFC) 0 – 15ROOM CLASS (ROOM CLASS) 0 – 15ANNEX (ANX) 0 – 3GROUND/ UNDERGROUND (G) 0/1FLOOR (FLR) 1 – 127 MG U G LV
Page 252
CHAPTER 4 NDA-24288 Page 240 Revision 1.0 AGST AGST: Assignment of Guest Station Data 1. General This command assigns and deletes Guest Room Data. 2. Precautions 1. This command is used for the Hotel Application only. 2. The AGSN command changes the station number, and the AGCL command changes the Class data (TEC, RSC, SFC, etc.). 3. Only Telephone Equipment Classes (TECs) 5-8, 10, and 12 may be assigned Guest station. 4. The number of digits for a station number are designated by the ASYD command,...
Page 253
NDA-24288 CHAPTER 4 Page 241 Revision 1.0 AGST 3. Data Entry Instructions TEC LENS Enter the LENS XX X XX X Level No. (0-7) Group No. (00-31) Unit No. (0-3) Module Group No. (00-31) G 0 : Ground 1 : Underground TENANT NUMBER (TN) STATION NUMBER (STN) Max. 6 digitsTELEPHONE EQUIPMENT CLASS (TEC) 1-31...
Page 254
CHAPTER 4 NDA-24288 Page 242 Revision 1.0 AGST 4. Data Sheet TENANT NUMBER (TN)STATION NUMBER (STN) MAXIMUM 6 DIGITSLINE EQUIPMENT NUMBER (LENS)TELEPHONE EQUIPMENT CLASS (TEC) 1 – 31ROUTE RESTRICTION CLASS (RSC) 0 – 15SERVICE FEATURE CLASS (SFC) 0 – 15ROOM CLASS (ROOM CLASS) 0 – 15ANNEX (ANX) 0 – 3GROUND/ UNDER- GROUND (G) 0/1FLOOR (FLR) 1 – 127 MG U G LV
Page 255
NDA-24288 CHAPTER 4 Page 243 Revision 1.0 AASN AASN: Assignment of Alternated Administration Station Number 1. General This command changes a currently assigned Administration Station Number. 2. Precautions 1. This command is used for the Hotel Application only. 2. Input a number which is not currently assigned. If a station number currently being used is to be assigned as a new number, delete the station first via the RAST command. 3. When the “PKG CHECK” message is displayed during assignment, confirm...
Page 256
CHAPTER 4 NDA-24288 Page 244 Revision 1.0 AACL AACL: Assignment of Administration Station Class 1. General This command changes the data assigned to an Administration Station: Telephone Equipment Class (TEC), Service Feature Class (SFC), Route Restriction Class (RSC), ROOM CLASS and Floor Service Data. 2. Precautions 1. This command is used for the Hotel Application only. 2. Only Telephone Equipment Classes (TECs) 1-4, 12-15, 18-20 and 13 may be assigned via this command. 3. Floor Service Data is...
Page 257
NDA-24288 CHAPTER 4 Page 245 Revision 1.0 AACL 3. Data Entry Instructions TEC RSCANNEX G NOTE STN SFC TENANT NUMBER (TN) STATION NUMBER (STN) Max. 6 digitsTELEPHONE EQUIPMENT CLASS (TEC) 1-31 ROUTE RESTRICTION CLASS (RSC) 0-15SERVICE FEATURE CLASS (SFC) 0-15ROOM CLASS 0-15ANNEX (ANX) 0-3 GROUND/ UNDERGROUND (G) 0/1FLOOR (FLR) 1-127 112 1 1 1 : DP (10 pps)...
Page 258
CHAPTER 4 NDA-24288 Page 246 Revision 1.0 AGSN AGSN: Assignment of Alternated Guest Station Number 1. General This command changes a currently assigned Guest Station Number. 2. Precautions 1. This command is used for the Hotel Application only. 2. Input a number which is not currently assigned. If a station number currently being used is to be assigned as a new number, delete the station first via the RGST command. 3. When the “PKG CHECK” message is displayed during assignment, confirm the LENS...
Page 259
NDA-24288 CHAPTER 4 Page 247 Revision 1.0 AGCL AGCL: Assignment of Guest Station Class 1. General This command changes the data assigned to a Guest Station: Telephone Equipment Class (TEC), Service Feature Class (SFC), Route Restriction Class (RSC), ROOM CLASS and Floor Service Data [Annex (ANX), Ground/Underground (G), Floor (FLR)]. 2. Precautions 1. This command is used for the Hotel Application only. 2. Only Telephone Equipment Classes (TECs) 5-8, 10 and 12 may be assigned via this command. 3. Floor...
Page 260
CHAPTER 4 NDA-24288 Page 248 Revision 1.0 AGCL 3. Data Entry Instructions TEC RSCANNEX G NOTE STN SFC TENANT NUMBER (TN) STATION NUMBER (STN) Max. 6 digitsTELEPHONE EQUIPMENT CLASS (TEC) 1-31 ROUTE RESTRICTION CLASS (RSC) 0-15SERVICE FEATURE CLASS (SFC) 0-15ROOM CLASS 0-15ANNEX (ANX) 0-3 GROUND/ UNDERGROUND (G) 0/1FLOOR (FLR) 1-127 112 1 1 Enter the RSC...