    							CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 55
    NOTE 3:Set the SW-1 and SW-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW-1 and SW-2 on all the DTI cards
    mounted in PIM0 to “OFF”.
    NOTE 5:Mount the DTI card which receives a source clock signal into PIM0.
    CONDITIONSDTI0 DTI1 DTI2 DTI3
    REMARKS
    SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2
    When one DTI is
    provided.ON OFF – – – – – –MP card will receive the 
    clock signal from DTI0 
    at its PLO0 input.
    When more than
    one DTI is
    provided.ON OFF OFF ON OFF OFF OFF OFFMP card will receive the 
    clock signal from DTI0 
    at its PLO0 input, under 
    normal conditions.
    Should a clock failure 
    occur with DTI0, MP 
    card will automatically 
    switch to the PLO1 input 
    which gets from DTI1. 
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 56  ND-70923 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    PN-24DTA-C (DTI)
    Locations of Lamps, Switches, and Connectors
    SENSE
    RUN
    MB
     
     
    CRC 
    PCM 
    FRM 
    RMT 
    AIS 
    BL 
       
     
     
     
     
     
      SW1
    SW0
    JRR1
    AISS MAS
    JPR0
    JPS 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 57
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) 
    errors.
    PCM Red Remains lit when detecting PCM signal loss.
    FRM Red Remains lit when detecting Frame Alignment signal loss.
    RMT Red Remains lit when receiving Frame Alignment signal loss alarm 
    from a distant office.
    AIS Red Remains lit when a pattern of consecutive “1” is received. The 
    distant office transmits this signal for a loop-back test.
    BL Red B Channel status
    ON : More than 10 channels are busy
    OFF : All channels are idle
    Flash (60 IPM) : Only one channel is busy
    Flash (120 IPM) : 2 through 10 channels are busy 
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 58  ND-70923 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-3 Not used
    4-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    (Continued)
    F
    4
    AP No.SW1-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW1-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 59
    SW0
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO 0 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO 0 input on MP 
    card. 
    2 
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO 1 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO 1 input on MP 
    card. 
    3ONRemote loop-back
    For normal operation
    4ONLocal loop-back (AIS send)
    For normal operation
    5Set equalizer according to the cable 
    length between the PBX and the 
    MDF. OFF
    6
    OFF
    7
    OFF
    8 Not used
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    OFF
    ON
    5 6 7 8
    1 2 3
    4
    OFF
    OFF
    ON
    OFF
    80-120m (262.5-394 ft.)
    SW0-5 SW0-6 SW0-7CABLE LENGTH
    ON ON0-40m (0-131.2 ft.)
    40-80m (131.2-262.5 ft.)
    120-160m (394-525 ft.)
    160-200m (525-656 ft.)
    Signal is not sent ON ON ON
    ON ON OFF
    OFF ON OFF
    ON OFF ON
    OFF OFF OFF
    ON
    ON
    OFF 
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 60  ND-70923 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION-
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.SW1
    (Piano Key SW)
    NOTE 41 Not used
    2 Not used
    3 Not used
    4ON AP No. 04-15
    OFF AP No. 20-31
    JPR0 (Jumper pin)
    UPNeutral grounding on the receiving
    line is provided.
    Neutral grounding on the receiving
    line is not provided.
    JPR1 (Jumper pin)
    Line impedance: 100 ohms
    Left Line impedance: 110 ohms
    JPS (Jumper pin)
    UPNeutral grounding on the transmit-
    ting line is provided.
    Neutral grounding on the transmit-
    ting line is not provided.
    MAS (Jumper pin)
    UP Clock Source
    Clock Receiver
    AISS (Jumper pin) AIS signal is sent out when make-
    busy or power on.
    DOWNAIS signal is not sent out when 
    make-busy or power on.
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    DOWN
    Right
    DOWN
    DOWN
    UP 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 61
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card.
    NOTE 3:Set SW0-1 and SW0-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards
    mounted in PIM0 to “OFF”.
    NOTE 5:Mount the DTI card which receives a source clock signal into PIM0.
    CONDITIONSDTI0 DTI1 DTI2 DTI3 DTI4
    REMARKS
    SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2
    When one DTI is 
    provided.ONOFF––––––––MP card will receive the 
    clock signal from DTI0 at its 
    PLO0 input.
    When more than 
    one DTI is pro-
    vided.ON OFF OFF ON OFF OFF OFF OFF OFF OFFMP card will receive the 
    clock signal from DTI0 at its 
    PLO0 input, under normal 
    conditions.
    Should a clock failure occur 
    with DTI0, MP card will auto-
    matically switch to the PLO1 
    input which gets clock from 
    DTI1. 
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 62  ND-70923 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    PN-SC01 (DCH)
    Locations of Lamps, Switches and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LC Green Remains lit when communications are normally ongoing with the 
    D Channel data links connected.
    LPB Green Not used
    SENS
    RUN
    MB
    SW0
    LC 
    LPB SW1 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 63
    Switch Settings
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to 
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    SW0
    (Piano Key SW)1 Always set to OFF
    2 Always set to OFF
    3 Always set to OFF
    4ON AP No. 04-15
    OFF AP No. 20-31
    (Continued)
    F
    4
    AP No.SW0-4: ON04 05 06 07 08 09 10 11 12 13 14 15
    SW0-4: OFF20 21 22 23 24 25 26 27 28 29 30 31
    SW No.456789ABCDEF
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF 
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 64  ND-70923 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Card
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card. SW1 (Dip SW)
    1 Always set to OFF
    2 Always set to OFF
    3 Always set to OFF
    4 Always set to OFF
    5 Always set to OFF
    6 Always set to OFF
    7 Always set to OFF
    8 Always set to OFF
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ON
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF 
    						