    							 NEAX2000 IVS2 Q-SIG System ManualPage 24  ND-70923 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure
    Mounting CONN Card
    When providing CONN (PZ-M542/M557) card to connect a coaxial cable for 24-DTI/30-DTI, do
    the following installation.
    (1) Confirm the correct switch setting of the CONN card. See CHAPTER 4, Page 41.
    (2) Mount the CONN card to LTC connector on BWB in the PIM which accommodates DTI 
    cards.
    For details, refer to the Installation Procedure Manual. 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 25
    Selection of PLO in MP Card
    (1) Confirm the correct switch settings of MP card. See CHAPTER 4, Page 41.
    (2) Mount the MP card on the MP slot of PIM0. 
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 26  ND-70923 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure
    DTI Cable Connection via MDF
    When you use a twisted-pair cable, connect the cable to a CSU via the MDF as shown in 
    Figure 2-3.
     Location of AP Slots and LTC Connectors for DTI -  Page 27
     Example of MDF Cross Connection for DTI - Page 28
    Figure 2-3  Cable Connection via MDF
    CSU MDF
    LT C 0 / LT C 1 / LT C 2 / LT C 3  TWISTED-PAIR
    CABLE 24-DTI BWBPBX
    (SHIELD TYPE)
    MAX. 400 m (1310 ft.) CONNECTOR 30-DTI/ 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 27
    Figure 2-4 shows LTC connector corresponds with the AP slots, and DTI pin assignment for each
    AP slot.
    Figure 2-4  Location of the AP Slots and the LTC Connectors for DTI
    LT C 0
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25RA 
    TA  
     
     
     
     
     
     
    RA 
    TA  
     
     
     
     
     
     
    RA 
    TA  
     
     
     
     
     
     
    MJ 
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    MNRA 
    TA  
     
     
     
     
     
     
    RA 
    TA  
     
     
     
     
     
     
    RA 
    TA  
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TBRA 
    TA  
     
     
     
     
     
     
    RA 
    TA  
     
     
     
     
     
     
    RA 
    TA  
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TBRA 
    TA  
     
     
     
     
     
     
    RA 
    TA  
     
     
     
     
     
     
    RA 
    TA  
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP00 
    SLOT
    AP01 
    SLOT
    AP02 
    SLOT
    LT C 1
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP03 
    SLOT
    AP04 
    SLOT
    AP05 
    SLOT
    LT C 2
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP08 
    SLOT
    AP07 
    SLOT
    AP06 
    SLOT
    AP11 
    SLOT
    AP10 
    SLOT
    AP09 
    SLOT
    LT C 3
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50 L 
    T 
    1 
    1 
    / 
    A 
    P 
    1 
    1 L 
    T 
    1 
    0 
    / 
    A 
    P 
    1 
    0 
      L 
    T 
    0 
    9 
    / 
    A 
    P 
    0 
    9 
      L 
    T 
    0 
    8 
    / 
    A 
    P 
    0 
    8 
      L 
    T 
    0 
    7 
    / 
    A 
    P 
    0 
    7 
      L 
    T 
    0 
    6 
    / 
    A 
    P 
    0 
    6 
      L 
    T 
    0 
    5 
    / 
    A 
    P 
    0 
    5 
      L 
    T 
    0 
    4 
    / 
    A 
    P 
    0 
    4 
      L 
    T 
    0 
    3 
    / 
    A 
    P 
    0 
    3 
      L 
    T 
    0 
    2 
    / 
    A 
    P 
    0 
    2 
      L 
    T 
    0 
    1 
    / 
    A 
    P 
    0 
    1 
      L 
    T 
    0 
    0 
    / 
    A 
    P 
    0 
    0 
      
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 28  ND-70923 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure
    Figure 2-5 shows an example of the cable connection when the 24-DTI/30-DTI card is mounted
    in the AP05 slot of PIM0.
    Figure 2-5  Example of MDF Cross Connection for DTI
    17 
    18 
    19 
    20RA 
    TA42 
    43 
    44 
    45RB 
    TB LT C 1  ( J )42 
    43 
    44 
    45RB 
    TB17 
    18 
    19 
    20RA 
    TA LT C 1  ( P ) PIM 0
    JP MDF 24-DTI/30-DTI
    AP05
    RA
    RB
    TA
    TB17
    42
    18
    4317
    42
    18
    43RA
    RB
    TA
    TBTO CSU LT C 1
    RECEIVE
    TRANSFER 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 29
    DTI Cable Connection via CONN Card
    When you use an coaxial cable, connect the cable to a CSU via the CONN (PZ-M542/M557) card
    as shown in Figure 2-6.
    Figure 2-6  Cable Connection via the CONN Card
    CSU
    LT C 0 / LT C 1 / LT C 2 / LT C 3  COAXIAL CABLE 30-DTI BWBPBX
    MAX. 6 dB loss at 1024 kHz
    CONN
    CONNECTOR 
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 30  ND-70923 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure
    Figure 2-7 shows an example of the cable connection when the 24-DTI/30-DTI card is mounted
    in the AP05 slot of PIM0.
    Figure 2-7  Example of Coaxial Cable Connection
    2  COAXIAL CONNECTOR
    1  LTC1 CONNECTOR
    17 
    18 
    19 
    20RA 
    TA42 
    43 
    44 
    45RB 
    TB LT C 1  ( J )17 
    18 
    19 
    20 RB 
    TB 42 
    43 
    44 
    45RA 
    TA LT C 1  ( P ) PIM 0
    JPCONN
    30-DTI
    AP05
    RA
    RB
    TA
    TB17
    42
    18
    4317
    42
    18
    43TO CSU
    LT C 1
    RECEIVE
    RCV
    SEND TRS
    2   1  
    						
    							NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 31
    CHAPTER 3
    SYSTEM DATA
    PROGRAMMING
    This chapter explains the programming procedure to provide Q-SIG
    feature on the PBX. 
    						
    							 NEAX2000 IVS2 Q-SIG System ManualPage 32  ND-70923 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    How to Read This Chapter
    HOW TO READ THIS CHAPTER
    In the programming procedure, the meaning of (1), (2) and markings are as follows.
    (1) : 1st Data
    (2) : 2nd Data
    : Initial Data
    With the system data clear command (CM00, CM01), the data with this marking is
    automatically assigned for each command.
    : System Initialization
    After entering the data, system reset is required (Depress SW1 on the MP
    card).
    : DCH Initialization
    A reset of the DCH card is required after data setting.
    Set the Make Busy switch to UP and then Down.
    INITIAL
    DCH INITIAL 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    DTI Assignment
    NEAX2000 IVS2 Q-SIG System Manual    
    ND-70923 (E), Issue 1.0   Page 33
    DTI ASSIGNMENT
    DESCRIPTION DATA
    Assign an AP number to the DTI card.
    The AP number must match the SENS 
    switch setting on the DTI card.
    (1)
    (2)Y=0
    04-15, 20-31: AP No.
    09: DTI card   
    Assign a Q-SIG trunk number to each 
    channel number on the DTI card.
    The system allocates time slots to 
    consecutive channels from lowest to 
    highest channel number assigned. To 
    minimize the number of time slots 
    allocated, assign trunk numbers to the 
    consecutive channels on each card.
    Never skip channels in CM07.
    (1)
    (2)YY=01   
    XX ZZ
    XX: 04-15, 20-31: AP No. assigned by 
    CM05 Y=0
    ZZ: 01-15, 17-31: Channel No. of DTI
     NOTE 1
    D000-D255: Trunk No.
    Trunk No. already assigned by CM10 
    cannot be used. 
    Assign the access code for Q-SIG to LCR 
    Group 0-3. 
    (1)
    (2)Y=0-3 Numbering Plan Group 0-3
    X-XXXX: Access code
    A126-A129: LCR Group 0-3
    CM07
    CM20 START