    							NAME DISPLAY
      AN
    OPEN APPLICATION INTERFACE (OAI)
    INSTALLATION GUIDE
    NEC America, Inc.
    NDA-30011-003
    Revision 3.0
    December, 1996
    Stock # 241718 
    						
    							LIABILITY DISCLAIMER
    NEC America reserves the right to change the specifications,  functions, 
    or features in this document at any time without notice.  NEC America 
    has prepared this document for use by its employees and customers.  The 
    information contained herein is the property of NEC  America and shall 
    not be reproduced without prior written approval from NEC America.
    Copyright 1996
    NEC America, Inc. 
    						
    							NDA-30011  Revision 3.0Page i
    Name Display Installation Guide CONTENTS
    TABLE OF CONTENTS
    Page
    Chapter 1 - Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1
    Chapter 2 - Application Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
    Step 1 – Application Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
    Step 2 – Primary Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    Step 3 – Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    Step 4 – Secondary OAI Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
    Step 5 – User-defined Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
    Chapter 3 - Database Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7
    Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
    Field  Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
    Chapter 4 - MAT Assignment  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9 
    						
    							Page iiNDA-30011  Revision 3.0
    CONTENTS Name Display Installation Guide
    This Page Left Blank. 
    						
    							NDA-30011   Revision 3.0Page 1
    Name Display Installation Guide Introduction
    Chapter 1 Introduction
    This guide provides specific field entries that need to be made in the process of 
    installing and configuring Name Display. In addition to this guide, use the 
    following manuals for this installation:
    Applications Manager (APM) Installation Manual – Contains step-by-step 
    instructions for installing the software from the release media.
    Applications Manager (APM) Operations Manual – Explains how 
    applications like Name Display are configured in the APM environment, using 
    the entries and values provided in this guide.
    NEAX2400 System Manuals – Give very detailed explanations about the 
    assignments that need to be made through the Maintenance Administration 
    Terminal (MAT) commands on the NEAX2400.
    Briefly, the installation and set up of Name Display involves the following 
    sequence of steps:
    Software Installation 
    Name Display software must first be loaded from the release media. Log in to the 
    APM Platform Management Menu, select the Installation of Applications/
    Packages option, and follow the instructions provided in the APM Installation 
    Manual to complete this part of the installation.
    Application Configuration
    Name Display is internally supported by the APM and must be configured in the 
    APM environment. Chapter 2 of this guide provides the information that must be 
    entered into this APM configuration file. Use the instructions provided in the APM 
    Operations Manual to make the entries provided in this section.
    Database Requirements
    Name Display requires one application database that is constructed and maintained 
    through the APM Database Administration option. The process begins with the 
    creation of a master definition file and its related master database. Then an 
    application definition file is constructed which enables the processing of the master 
    database file into a Name Display application database. Chapter 3 of this guide 
    defines the information which must be included in these definition and database 
    files. Use the instructions provided in the APM Operations Manual to make the 
    entries contained in this section.
    MAT Assignments
    Specific data settings must be assigned at the NEAX2400 Maintenance 
    Administration Terminal (MAT) before Name Display will function. Chapter 4 of 
    this guide specifies the necessary commands and the values at which they are to be 
    set. Use the instructions provided in the NEAX2400 IMS System Manuals to 
    make the entries contained in this section. 
    						
    							Page 2NDA-30011   Revision 3.0
    Introduction Name Display Installation Guide
    The installation process, including its presentation in this manual and reference to 
    other manuals that are necessary, is illustrated below.
    Figure 1-1   Name Display Installation Requirements
    Discussed in:Instructions In
    Chapter 1Software InstallationAPM Installation
    Introduction
    Software Release MediaManual 
    Chapter 2Application CharacteristicsAPM Operations
    Application Configuration
    Primary Parameter ConfigurationManual
    OAI Facilities (Optional)
    OAI Configuration Parameters (Optional)
    User-Defined Parameters
    Chapter 3Master Definition FileAPM Operations
    Database Requirements
    Master Database FileManual
    Application Definition File
    Application Database
    Chapter 4ASYD: (Assignment of System Data)NEAX2400 IMS
    Maintenance Administration System Manuals
    Terminal (MAT) Assignment 
    						
    							NDA-30011   Revision 3.0Page 3
    Name Display Installation Guide Application Configuration
    Chapter 2 Application Configuration
    Name Display is configured into the APM system using the Add function of the 
    Application Configuration option on the APM System Administration menu. To 
    access the Application Configuration option:
    1. Enter the APM option from the APM Platform Management Menu.
    2. Enter the System Administrator password at the APM password screen.
    3. Enter the Application Configuration option from the System Administration 
    menu.
    This section contains the information that should be entered in the configuration 
    file for Name Display. For specific instructions on what these parameters mean and 
    how to make these entries, use the APM Operations Manual.
    Step 1 – Application Characteristics
    ParameterEntryDescription
    OAI Application Y Indicates whether or not (Yes or No) 
    this component is an OAI application 
    because it communicates with the 
    NEAX2400 using OAI processes.
    CRT Application N Indicates whether or not (Yes or No) 
    this component requires a terminal 
    screen that is of the same type as the 
    one used by the APM.
    Communication Queue N Indicates whether or not (Yes or No) 
    this non-OAI component needs an IPC 
    queue to communicate with other 
    processes. 
    						
    							Page 4NDA-30011   Revision 3.0
    Application Configuration Name Display Installation Guide
    Step 2 – Primary Configuration Parameters 
    On the APM Configuration Entry screen, make the entries shown below to the 
    parameters indicated: 
    Parameter
    EntryDescription
    Application Name Name_Display  Indicates the name to be displayed 
    in the APM menus. This name is 
    displayed however it is entered 
    here; i.e., capital letters, lowercase, 
    etc.
    Executable Filename /oai/app/namedisp Indicates the path name of the 
    executable file.
    Group (make no entry) (Name
    _Display is not a member of 
    a group of applications.)
    Response Mode I(gnore) Indicates the action that APM is to 
    take with the component when a 
    member of its group terminates; 
    the I (Ignore) serves as a default 
    value since neither component 
    belongs to a group.
    Initialization Batch Y Indicates whether or not 
    Name
    _Display is to be initialized 
    automatically when the OAI 
    system is initialized.
    Termination  Mode M(essage) Indicates how the APM is to notify 
    Name
    _Display to terminate.
    Standard Output /dev/null Indicates where Name
    _Display 
    output is sent.
    Number of Restarts 0 Indicates the number of times the 
    APM may restart Name
    _Display in 
    the event that it terminates 
    erroneously; 0 indicates that it is 
    not to be restarted at all.
    Step 3 – Facilities 
    According to instructions in the APM Operations Manual, designate the 
    following NEAX2400 facility for the Name
    _Display component using the 
    Facilities command on the APM Configuration Entry screen:
    FLF – Free Location Facility 
    						
    							NDA-30011   Revision 3.0Page 5
    Name Display Installation Guide Application Configuration
    Step 4 – Secondary OAI Configuration Parameters 
    Using the OAI-Conf command on the APM Configuration Entry screen, make the 
    entry shown for each of the following parameters required by Name
    _Display. Use 
    the instructions provided for this option in the APM Operations Manual:
    Parameter
    EntryDefinition
    Database Name #1 /oai/db/cur/namefile Indicates the path name of the 
    database containing the extension 
    numbers, display names, and their 
    corresponding employee names. 
    The database filename namefile, 
    listed here with its path, should be 
    used as the name of the 
    corresponding Application 
    Definition File. (See Create an 
    Application Definition File on 
    page 7 for more information.)
    Tenant Number 1 Specifies the number of the tenant 
    to which the extensions apply.
    Source Link Name OAI1X25 The port on the source side of the 
    communication link; entry should 
    correspond to a link name in the 
    APM system configuration file.
    Destination Link Name PBX1X25 The port on the destination side of 
    the communication link; entry 
    should correspond to a link name 
    in the APM system configuration 
    file.
    Association Recovery 10 The number of seconds 
    Name
    _Display will wait before 
    trying to re-establish an association 
    with the NEAX that has been 
    released. 
    						
    							Page 6NDA-30011   Revision 3.0
    Application Configuration Name Display Installation Guide
    Step 5 – User-defined Parameters
    Make the following additional parameter entry through the UserDefined command 
    on the APM Configuration Entry screen.
    Parameter
    EntryDefinition
            #1 16 The length of the Display Name 
    field in the Name Display database 
    (8 or 16 characters); this entry must 
    agree with the size of the Display 
    Name field in the database. (See 
    Display Name in Field Definitions 
    on page 8 for more information.)
    This completes the configuration of Name
     Display in the APM. Now go to 
    Database Requirements to create its database support. 
    						