    							LOCATION STATUS INFORMATION
    INSTALLATION GUIDE
    NEC America, Inc.
    NDA-30043-002
    Revision 2.0
    March, 1997
    Stock # 241716 
    						
    							LIABILITY DISCLAIMER
    NEC America reserves the right to change the specifications,  functions, 
    or features in this document at any time without notice.  NEC America 
    has prepared this document for use by its employees and customers.  The 
    information contained herein is the property of NEC  America and shall 
    not be reproduced without prior written approval from NEC America.
    Copyright 1996
    NEC America, Inc. 
    						
    							NDA-30043  Revision 2.0Page i
    Location Status Information - Installation Guide CONTENTS
    TABLE OF CONTENTS
    Page
    Chapter 1 - Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1
    Chapter 2 - Application Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
    Step 1 – Application Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
    Step 2 – Primary Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    Step 3 – Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    Step 4 – Secondary OAI Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
    Step 5 – User-Defined Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
    Chapter 3 - Database Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7
    Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
    Extension Database Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
    Field Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
    Employee Identification Database Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
    Field Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
    Chapter 4 - Control Options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   11
    Chapter 5 - NEAX Command Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   13
    NEAX2400 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
    AOKC  Command:   (Assignment of OAI  Key Codes)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
    AKYD  Command:   (Assignment of Dterm Function Key). . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
    Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
    NEAX2000 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
    CMD79:  (Assignment of Internet Address) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
    CMD7:  (Assignment of MSF Operation Code) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
    CM90:  (Assignment of the OAI Function Key for MSF)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17 
    						
    							Page iiNDA-30043  Revision 2.0
    CONTENTS Location Status Information - Installation Guide
    This Page Left Blank. 
    						
    							NDA-30043   Revision 2.0Page 1
    Location Status Information - Installation Guide Introduction
    Chapter 1 Introduction
    This guide provides specific field entries that need to be made in the process of 
    installing and configuring Location Status Information.  In addition to this guide, 
    use the following manuals for this installation:
    •Applications Manager (APM) Installation Manual – Contains step-by-step 
    instructions for installing the software from the release media.
    Applications Manager (APM) Operations Manual – Explains how applications 
    like Location Status Information are configured in the APM environment, 
    using the entries and values provided in this guide.
     NEAX System Manuals - Give very detailed explanations about the 
    assignments that need to be made with the NEAX2400 Maintenance 
    Administration Terminal (MAT) commands, the NEAX2000 Customer 
    Administration Terminal (CAT), or the NEAX2000 Maintenance Operations 
    Console (MOC).
    Briefly, the installation and set up of Location Status Information involves the 
    following processes:  
    Software Installation - Location Status Information software must first be 
    loaded from the release media.  Log in to the APM Platform Management 
    Menu, select the Installation of Applications/Packages option, and follow the 
    instructions provided in the APM Installation Manual to complete this part of 
    the installation. 
    Application Configuration - Location Status Information is internally 
    supported by the APM and must be configured in the APM environment. 
    Application Configuration of this guide provides the information that must be 
    entered into this APM configuration file.  Use the instructions provided in the 
    APM Operations Manual to make the entries provided in this section.
    Database Requirements - Location Status Information requires two 
    application databases which are constructed and maintained through the APM 
    Database Administration option.  Database Requirements of this guide defines 
    the information which must be included in these database files.  Use the 
    instructions provided in the APM Operations Manual to make the entries 
    contained in this section.
    Control Options - If the AMS_to_LSI utility is running with AMS, 
    AMS_to_LSI must be set up to run nightly.
    NEAX Command Assignments - Before Location Status Information will 
    function, specific data settings must be assigned at the NEAX2400 
    Maintenance Administration Terminal (MAT), the NEAX2000 Customer 
    Administration Terminal (CAT), or the NEAX2000 Maintenance Operations 
    Console (MOC). NEAX Command Assignments specifies the necessary 
    commands and the values at which they are to be set. Use the instructions 
    provided in the appropriate NEAX System Manuals to make the entries 
    contained in this section.
    The installation process, including its presentation in this manual and reference to 
    other required manuals, is illustrated below: 
    						
    							Page 2NDA-30043   Revision 2.0
    Introduction Location Status Information - Installation Guide
     
    LOCATION  STATUS  INFORMATION 
    INSTALLATION  REQUIREMENTS
    Discussed in
    Chapter 1
    Introduction
    Chapter  2
    Chapter  3
    Chapter  4
    Chapter  5Software Installation
    Software Release Media
    Application Configuration
    Application Characteristics
    Primary Parameter Configuration 
    OAI Facilities (Optional)
    OAI Configuration Parameters (Optional)
    User-Defined Parameters
    Database Requirements
    Master File Definitions
    Master Database File
    Application File Definition
    Application Database
    Control OptionsInstructions  in:
    APM Installation 
    Manual
    APM Operations 
    Manual
    APM Operations 
    Manual
    APM Operations 
    Manual
    NEAX2400 MAT Commands
    NEAX2000 CAT/MOC CommandsNEAX2400 IMS
    System Manuals
    NEAX2000 IVS
    System Manuals 
    						
    							NDA-30043   Revision 2.0Page 3
    Location Status Information - Installation Guide Application Configuration
    Chapter 2 Application Configuration
    Location Status Information is set up in the APM system using the Add function 
    of the Application Configuration option on the APM System Administration menu:
    1. Enter the APM option from the APM Platform Management Menu.
    2. Enter the System Administrator password at the APM password screen.  
    3. Enter the Application Configuration option from the System Administration 
    menu.
    This section contains the information that should be entered to the configuration 
    file for Location Status Information.  For specific instructions on what these 
    parameters mean and how to make these entries, refer to the APM Operations 
    Manual.
    Note:Configure AMS_to_LSI only if  the Attendant Management System (AMS) is  in-
    stalled on the same  UAP as Location Status Information (LSI) and the LSI data-
    base will be generated from the AMS database.  This option is only available on 
    the NEAX2400 System.
    Step 1 – Application Characteristics
    In the APM Application Configuration option, choose the Add command to display 
    the Define Application Characteristics screen.  Then make the entries exactly as 
    shown below:
    Parameter LSI EntryAMS_to_LSI
    EntryDefinition
    OAI Application Y NWhether (Yes or No) the application communi-
    cates with the NEAX2400 using OAI processes.
    CRT Application N NWhether (Yes or No) the application requires a 
    terminal screen of the same type as the one used 
    by the APM.
    Communication 
    QueueNNWhether (Yes or No) the application needs an 
    IPC queue to communicate with other process-
    es. 
    						
    							Page 4NDA-30043   Revision 2.0
    Application Configuration Location Status Information - Installation Guide
    Step 2 – Primary Configuration Parameters
    On the APM Configuration Entry screen, make the following entries  for  the 
    parameters shown below:
     
    Step 3 – Facilities
    According to instructions in the APM Operations Manual, designate the following  
    facilities for Location Status Information using the Facilities command on the 
    APM Configuration Entry screen:
    MRFI Mode Release Facility (I) SCF Switch Control Facility
    MRFR Mode Release Facility(R) TCFD Terminal Control Facility (D)
    MSF OAI Mode Set Facility TCFI Terminal Control Facility (I)
    NTF Number Transfer Facility
    Note:The same MSF identification number (i.e., from 128 to 192) that is selected in the 
    APM during Step 3 must be assigned to 
    Location Status Information with the ap-
    propriate NEAX commands.  See NEAX Command Assignments for more infor-
    mation. Parameter LSI  Entry AMS_to_LSI
      Entry Definition
    Application
    NameLocation_Status AMS_to_LSIThe name to be displayed in the 
    APM menus.  This name is 
    displayed exactly as it is entered 
    here.
    Executable 
    Filename/oai/app/lsi /oai/app/bldlsiThe path name of the executable 
    file.
    Group (no entry) (no entry)The application is not a group 
    member.
    Response Mode I(gnore) I(gnore)The default value, since the 
    components do not belong to a 
    group.
    Initialization
    BatchN(o) N(o)The application is not to be 
    initialized automatically when the 
    OAI system is initialized.
    Termination
    ModeM(essage) T(erminate)How the APM is to notify the 
    application to terminate.
    Standard Output /oai/log/dbg/lsi.out /oai/log/dbg/bldlsi.out Where output is sent.
    Number of Restarts 0 0The APM is not to restart the 
    application if it terminates in 
    error. 
    						
    							NDA-30043   Revision 2.0Page 5
    Location Status Information - Installation Guide Application Configuration
    Step 4 – Secondary OAI Configuration Parameters
    Note:
    Entries for parameters that are marked with an asterisk (*) should be made ex-
    actly as shown.  All other entries in this section serve as examples only.
    Using the OAI-Conf command on the APM Configuration Entry screen, make the 
    entry shown for each of these parameters required by Location Status 
    Information.  Use the instructions provided for this option in the 
    APM Operations 
    Manual:
    † – The maximum Tenant Number for the NEAX2000 is 64.
    Parameter Entry Definition
    Database Name #1* /oai/db/cur/lsi_extnThe pathname of the database containing    
    extension information.  The database           
    filename (i.e., lsi_extn) shown here with its 
    path should be entered as the name of the    
    application database as noted in the             
    “Database Requirements” section.
    Database Name #2* /oai/db/cur/lsi_msgThe pathname of the database containing the 
    possible messages.  The database filename 
    (i.e., lsi_msg) listed here with its path should 
    be entered as the name of the application 
    database as noted in the “Database 
    Requirements” section.
    Time-out Value #1 20The number of seconds LSI waits for user 
    input before it releases the D
    term.
    Time-out Value #2 10The number of seconds LSI displays a 
    message on the D
    term LCD.
    Tenant Number (0-64)†1 The number of the tenant that LSI serves.
    Source Link Name OAI1TCPThe port on the source side of the 
    communication link.  This entry should 
    match a link name in the APM system 
    configuration file.
    Destination Link Name PBX1TCPThe port on the destination side of the 
    communication link.  This entry should 
    match a link name in the APM system 
    configuration file.
    Association Recovery 10The number of seconds LSI waits before 
    trying to re-establish an association with the 
    NEAX that has been released. 
    						
    							Page 6NDA-30043   Revision 2.0
    Application Configuration Location Status Information - Installation Guide
    Step 5 – User-Defined Parameters
    Make these parameter entries for LSI installation through the UserDefined 
    command on the APM Configuration Entry screen:
    This completes the configuration of Location Status Information in the APM.  
    Refer to Database Requirements for information on how to create its database 
    support.
    Make this parameter entry for AMS_to_LSI installation through the UserDefined 
    command on the APM Configuration Entry screen:
     
    This completes the configuration of AMS_to_LSI in the APM.  Refer to Control 
    Options  to choose its control options.
    User-
    DefinedLSI Entry Definition
    #1 Installation-dependent This is the OAI key assigned to LSI.
    #2 /oai/db/cur/Lsi_extn The full pathname of the master LSI extension database.
    #3 Installation-dependent Set to 1 if using in conjunction with AMS.
    Set to  2 if using in conjunction with AMS and a space 
    exists between  the  last name and first name  in the AMS 
    database.  (i.e., ’last name,  first name’)
    User-
    DefinedAMS_to_LSI Entry Definition
    #1 /oai/db/cur/Lsi_extnThis is the name of the master extension database for 
    LSI. 
    						