LOCATION STATUS INFORMATION INSTALLATION GUIDE NEC America, Inc. NDA-30043-002 Revision 2.0 March, 1997 Stock # 241716
LIABILITY DISCLAIMER NEC America reserves the right to change the specifications, functions, or features in this document at any time without notice. NEC America has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America and shall not be reproduced without prior written approval from NEC America. Copyright 1996 NEC America, Inc.
NDA-30043 Revision 2.0Page i Location Status Information - Installation Guide CONTENTS TABLE OF CONTENTS Page Chapter 1 - Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Chapter 2 - Application Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Step 1 – Application Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Step 2 – Primary Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Step 3 – Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Step 4 – Secondary OAI Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Step 5 – User-Defined Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Chapter 3 - Database Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Extension Database Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Field Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Employee Identification Database Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Field Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Chapter 4 - Control Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Chapter 5 - NEAX Command Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 NEAX2400 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 AOKC Command: (Assignment of OAI Key Codes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 AKYD Command: (Assignment of Dterm Function Key). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 NEAX2000 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 CMD79: (Assignment of Internet Address) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 CMD7: (Assignment of MSF Operation Code) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 CM90: (Assignment of the OAI Function Key for MSF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Page iiNDA-30043 Revision 2.0 CONTENTS Location Status Information - Installation Guide This Page Left Blank.
NDA-30043 Revision 2.0Page 1 Location Status Information - Installation Guide Introduction Chapter 1 Introduction This guide provides specific field entries that need to be made in the process of installing and configuring Location Status Information. In addition to this guide, use the following manuals for this installation: •Applications Manager (APM) Installation Manual – Contains step-by-step instructions for installing the software from the release media. Applications Manager (APM) Operations Manual – Explains how applications like Location Status Information are configured in the APM environment, using the entries and values provided in this guide. NEAX System Manuals - Give very detailed explanations about the assignments that need to be made with the NEAX2400 Maintenance Administration Terminal (MAT) commands, the NEAX2000 Customer Administration Terminal (CAT), or the NEAX2000 Maintenance Operations Console (MOC). Briefly, the installation and set up of Location Status Information involves the following processes: Software Installation - Location Status Information software must first be loaded from the release media. Log in to the APM Platform Management Menu, select the Installation of Applications/Packages option, and follow the instructions provided in the APM Installation Manual to complete this part of the installation. Application Configuration - Location Status Information is internally supported by the APM and must be configured in the APM environment. Application Configuration of this guide provides the information that must be entered into this APM configuration file. Use the instructions provided in the APM Operations Manual to make the entries provided in this section. Database Requirements - Location Status Information requires two application databases which are constructed and maintained through the APM Database Administration option. Database Requirements of this guide defines the information which must be included in these database files. Use the instructions provided in the APM Operations Manual to make the entries contained in this section. Control Options - If the AMS_to_LSI utility is running with AMS, AMS_to_LSI must be set up to run nightly. NEAX Command Assignments - Before Location Status Information will function, specific data settings must be assigned at the NEAX2400 Maintenance Administration Terminal (MAT), the NEAX2000 Customer Administration Terminal (CAT), or the NEAX2000 Maintenance Operations Console (MOC). NEAX Command Assignments specifies the necessary commands and the values at which they are to be set. Use the instructions provided in the appropriate NEAX System Manuals to make the entries contained in this section. The installation process, including its presentation in this manual and reference to other required manuals, is illustrated below:
Page 2NDA-30043 Revision 2.0 Introduction Location Status Information - Installation Guide LOCATION STATUS INFORMATION INSTALLATION REQUIREMENTS Discussed in Chapter 1 Introduction Chapter 2 Chapter 3 Chapter 4 Chapter 5Software Installation Software Release Media Application Configuration Application Characteristics Primary Parameter Configuration OAI Facilities (Optional) OAI Configuration Parameters (Optional) User-Defined Parameters Database Requirements Master File Definitions Master Database File Application File Definition Application Database Control OptionsInstructions in: APM Installation Manual APM Operations Manual APM Operations Manual APM Operations Manual NEAX2400 MAT Commands NEAX2000 CAT/MOC CommandsNEAX2400 IMS System Manuals NEAX2000 IVS System Manuals
NDA-30043 Revision 2.0Page 3 Location Status Information - Installation Guide Application Configuration Chapter 2 Application Configuration Location Status Information is set up in the APM system using the Add function of the Application Configuration option on the APM System Administration menu: 1. Enter the APM option from the APM Platform Management Menu. 2. Enter the System Administrator password at the APM password screen. 3. Enter the Application Configuration option from the System Administration menu. This section contains the information that should be entered to the configuration file for Location Status Information. For specific instructions on what these parameters mean and how to make these entries, refer to the APM Operations Manual. Note:Configure AMS_to_LSI only if the Attendant Management System (AMS) is in- stalled on the same UAP as Location Status Information (LSI) and the LSI data- base will be generated from the AMS database. This option is only available on the NEAX2400 System. Step 1 – Application Characteristics In the APM Application Configuration option, choose the Add command to display the Define Application Characteristics screen. Then make the entries exactly as shown below: Parameter LSI EntryAMS_to_LSI EntryDefinition OAI Application Y NWhether (Yes or No) the application communi- cates with the NEAX2400 using OAI processes. CRT Application N NWhether (Yes or No) the application requires a terminal screen of the same type as the one used by the APM. Communication QueueNNWhether (Yes or No) the application needs an IPC queue to communicate with other process- es.
Page 4NDA-30043 Revision 2.0 Application Configuration Location Status Information - Installation Guide Step 2 – Primary Configuration Parameters On the APM Configuration Entry screen, make the following entries for the parameters shown below: Step 3 – Facilities According to instructions in the APM Operations Manual, designate the following facilities for Location Status Information using the Facilities command on the APM Configuration Entry screen: MRFI Mode Release Facility (I) SCF Switch Control Facility MRFR Mode Release Facility(R) TCFD Terminal Control Facility (D) MSF OAI Mode Set Facility TCFI Terminal Control Facility (I) NTF Number Transfer Facility Note:The same MSF identification number (i.e., from 128 to 192) that is selected in the APM during Step 3 must be assigned to Location Status Information with the ap- propriate NEAX commands. See NEAX Command Assignments for more infor- mation. Parameter LSI Entry AMS_to_LSI Entry Definition Application NameLocation_Status AMS_to_LSIThe name to be displayed in the APM menus. This name is displayed exactly as it is entered here. Executable Filename/oai/app/lsi /oai/app/bldlsiThe path name of the executable file. Group (no entry) (no entry)The application is not a group member. Response Mode I(gnore) I(gnore)The default value, since the components do not belong to a group. Initialization BatchN(o) N(o)The application is not to be initialized automatically when the OAI system is initialized. Termination ModeM(essage) T(erminate)How the APM is to notify the application to terminate. Standard Output /oai/log/dbg/lsi.out /oai/log/dbg/bldlsi.out Where output is sent. Number of Restarts 0 0The APM is not to restart the application if it terminates in error.
NDA-30043 Revision 2.0Page 5 Location Status Information - Installation Guide Application Configuration Step 4 – Secondary OAI Configuration Parameters Note: Entries for parameters that are marked with an asterisk (*) should be made ex- actly as shown. All other entries in this section serve as examples only. Using the OAI-Conf command on the APM Configuration Entry screen, make the entry shown for each of these parameters required by Location Status Information. Use the instructions provided for this option in the APM Operations Manual: † – The maximum Tenant Number for the NEAX2000 is 64. Parameter Entry Definition Database Name #1* /oai/db/cur/lsi_extnThe pathname of the database containing extension information. The database filename (i.e., lsi_extn) shown here with its path should be entered as the name of the application database as noted in the “Database Requirements” section. Database Name #2* /oai/db/cur/lsi_msgThe pathname of the database containing the possible messages. The database filename (i.e., lsi_msg) listed here with its path should be entered as the name of the application database as noted in the “Database Requirements” section. Time-out Value #1 20The number of seconds LSI waits for user input before it releases the D term. Time-out Value #2 10The number of seconds LSI displays a message on the D term LCD. Tenant Number (0-64)†1 The number of the tenant that LSI serves. Source Link Name OAI1TCPThe port on the source side of the communication link. This entry should match a link name in the APM system configuration file. Destination Link Name PBX1TCPThe port on the destination side of the communication link. This entry should match a link name in the APM system configuration file. Association Recovery 10The number of seconds LSI waits before trying to re-establish an association with the NEAX that has been released.
Page 6NDA-30043 Revision 2.0 Application Configuration Location Status Information - Installation Guide Step 5 – User-Defined Parameters Make these parameter entries for LSI installation through the UserDefined command on the APM Configuration Entry screen: This completes the configuration of Location Status Information in the APM. Refer to Database Requirements for information on how to create its database support. Make this parameter entry for AMS_to_LSI installation through the UserDefined command on the APM Configuration Entry screen: This completes the configuration of AMS_to_LSI in the APM. Refer to Control Options to choose its control options. User- DefinedLSI Entry Definition #1 Installation-dependent This is the OAI key assigned to LSI. #2 /oai/db/cur/Lsi_extn The full pathname of the master LSI extension database. #3 Installation-dependent Set to 1 if using in conjunction with AMS. Set to 2 if using in conjunction with AMS and a space exists between the last name and first name in the AMS database. (i.e., ’last name, first name’) User- DefinedAMS_to_LSI Entry Definition #1 /oai/db/cur/Lsi_extnThis is the name of the master extension database for LSI.