Page 1
CONFERENCE ROOM SCHEDULER AN OPEN APPLICATION INTERFACE (OAI) INSTALLATION GUIDE NEC America, Inc. NDA-30007-003 Revision 3.0 January, 1997 Stock # 241732
Page 2
LIABILITY DISCLAIMER NEC America reserves the right to change the specifications, functions, or features in this document at any time without notice. NEC America has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America and shall not be reproduced without prior written approval from NEC America. Copyright 1996 NEC America, Inc.
Page 3
NDA-30007 Revision 3.0Page i Conference Room Scheduler Installation Guide CONTENTS TABLE OF CONTENTS Page Chapter 1 - Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Application Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4
Page iiNDA-30007 Revision 3.0 CONTENTS Conference Room Scheduler Installation Guide This Page Left Blank.
Page 5
NDA-30007 Revision 3.0Page 1 Conference Room Scheduler Installation Guide Introduction Chapter 1 Introduction This guide provides specific field entries that need to be made in the process of installing and configuring Conference Room Scheduler. In addition to this guide, use the following manuals for this installation: •Applications Manager (APM) Installation Manual – Contains step-by-step instructions for installing the software from the release media. Applications Manager (APM) Operations Manual...
Page 6
Page 2NDA-30007 Revision 3.0 Introduction Conference Room Scheduler Installation Guide Mat Assignments There are data settings which must be assigned at the NEAX Maintenance Administration Terminal (MAT) before Conference Room Scheduler will function. Chapter 4 of this guide specifies the necessary commands and the values at which they are to be set. Use the instructions provided in the NEAX2400 IMS System Manuals to make the entries contained in this section. The installation process, including...
Page 7
NDA-30007 Revision 3.0Page 3 Conference Room Scheduler Installation Guide Application Configuration Chapter 2 Application Configuration Conference Room Scheduler is configured into the APM system using the Add function of the Application Configuration option on the APM System Administration menu: 1. Enter the APM option from the APM Platform Management Menu. 2. Enter the System Administrator password at the APM password screen. 3. Enter the Application Configuration option from the System...
Page 8
Page 4NDA-30007 Revision 3.0 Application Configuration Conference Room Scheduler Installation Guide Step 2 – Primary Configuration Parameters (Both Components) On the APM Configuration Entry screen, make the entries shown below to the parameters indicated: Parameter Description Conf_Room_Sch Conf_Room_Sch_Rpt Application Name Indicates the name to be displayed in the APM menus. This name is displayed in the same way it is entered here (i.e., capital letters, lower case, etc.)Conf_Room_Sch...
Page 9
NDA-30007 Revision 3.0Page 5 Conference Room Scheduler Installation Guide Application Configuration Step 3 – Facilities (Conf_Room_Sch only) According to instructions in the APM Operations Manual, designate the following NEAX2400 facilities for the Conf_Room_Sch component using the Facilities command on the APM Configuration Entry screen: MRFI Mode Release Facility (I) MRFR Mode Release Facility (R) MSF OAI Mode Set Facility NTF Number Transfer Facility TCFD Terminal Control Facility (D) Note: The...
Page 10
Page 6NDA-30007 Revision 3.0 Application Configuration Conference Room Scheduler Installation Guide Step 5 – User-Defined Parameters (Both Components) Make the following additional parameter entries through the UserDefined command on the APM Configuration Entry screen. Conf_Room_Sch User-defined Parameters Parameter Entry Definition Source Link Name OAI1X25 Identifies the port on the source side of the communication link; entry should correspond to a link name in the APM system configuration...