Home > MSI > Motherboard > MSI 945gm2 H Manual

MSI 945gm2 H Manual

    Download as PDF Print this page Share this page

    Have a look at the manual MSI 945gm2 H Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 62 MSI manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							5-10MS-7210 Micro-ATX Mainboard
    The InstallShield Wizard will begin automatically for installation showed as
    following:
    Click on the Next button to proceed the installation in the welcoming window. 
    						
    							5-11Introduction to Intel ICH7R SATA RAID
    After reading the license agreement in the following window, click Yes button to
    continue.The window shows the components to be installed. Click Next button to continue. 
    						
    							5-12MS-7210 Micro-ATX Mainboard
    Select the folder in which you want the program to be installed in the following
    window, and click Next button to start installation.Select a program folder in the following window where you want Setup to add the
    program icon. 
    						
    							5-13Introduction to Intel ICH7R SATA RAID
    Once the installation is complete, the following window appears. The following window appears to show the Intel Application Accelerator RAID
    Edition Setup installation status. 
    						
    							5-14MS-7210 Micro-ATX MainboardRAID Migration Instructions
    The Intel Matrix Storage Console offers the flexibility to upgrade from a single
    Serial ATA (SATA) hard drive to RAID configuration when an additional SATA hard
    drive is added to the system. This process will create a new RAID volume from an
    existing disk. However, several important steps must be followed at the time the
    system is first configured in order to take advantage of RAID when upgrading to a
    second SATA hard drive:
    1.BIOS must be configured for RAID before installing Windows XP on the
    single SATA hard drive. Refer to On Chip ATA Device for properly
    setting of the BIOS.
    2.Install the Intel Application Accelerator RAID Driver during Windows Setup.
    Refer to Installing Software for instructions on installing the driver
    during Windows Setup.
    3.Install the Intel Matrix Storage Console after the operating system is installed.
    To create a volume from an existing disk, complete the following steps:
    After the Intel Matrix Storage Console has been successfully installed and
    the system has rebooted, click on the Intel Application Accelerator shortcut link (Start
    --> All Programs --> Intel Matrix Storage Manager --> Intel Matrix Storage
    Console) and the following window will appear:MSI Reminds You...
    A Create from Existing Disk operation will delete all existing data
    from the added disk and the data cannot be recovered. It is critical to
    backup all important data on the added disk before proceeding. However,
    during the migration process, the data on the source disk is preserved. 
    						
    							5-15Introduction to Intel ICH7R SATA RAID
    Create RAID Volume from Existing Disk
    To create a RAID volume from an existing disk, choose Action --> Create
    RAID Volume from Existing Hard Drive.The Create RAID Volume from Existing Hard Drive Wizard pops up to lead
    you for the following procedure. Click Next to continue. 
    						
    							5-16MS-7210 Micro-ATX Mainboard
    (1) Step 1: Configure Volume
    Here you can configure the new RAID volume by entering the volume name,
    selecting the RAID level and strip size.† RAID Volume Name:
    A desired RAID volume name needs to be typed in where the ‘RAID_Volume0’ text
    currently appears above. The RAID volume name has a maximum limit of 16 characters.
    The RAID volume name must also be in English alphanumeric ASCII characters.
    † RAID Level:
    Select the desired RAID level:
    RAID 0 (Performance) –A volume optimized for performance will allow you to
    access your data more quickly.
    RAID 1 (Redundancy) –A volume optimized for data redundancy will provide
    you with a realtime duplicate copy of your data. Note:
    Only half of the available volume space will be avail-
    able for data storage.
    RAID 5 (Useful) –RAID 5 can be used on three or more disks, with zero
    or more spare-disks. The resulting RAID-5 device size
    will be (N-1)*S, where N is the how many drive, S is the
    size of the smallest drive in the array. If one of the disks
    fail, all data are still intact. It can rebuild the disk from
    the parity information. If spare disks are available,
    reconstruction will begin immediately after the device
    failure. If two disks fail simultaneously, all data are lost.
    RAID-5 can survive one disk failure, but not two or
    more. Both read and write performance usually
    increase, but can be hard to predict how much. Reads
    are similar to RAID-0 reads, writes can be either rather 
    						
    							5-17Introduction to Intel ICH7R SATA RAID
    (2) Select the source disk
    Then select the source disk that you wish to use and then click “--->” to
    move it to the Selected field. Then click Next to continue.
    It is very important to note which disk is the source disk (the one containing all
    of the information to be migrated) and which one is the target disk. On a RAID Ready
    system, this can be determined by making a note during POST of which port (e.g. Port
    0 or Port 1) the single disk is attached to.
    You can also use the Intel Application Accelerator RAID Edition utility before
    the second disk is installed to verify the Port and serial number of the drive that
    contains all the data.expensive (requiring read-in prior to write, in order to
    be able to calculate the correct parity information), or
    similar to RAID-1 writes. The write efficiency depends
    heavily on the amount of memory in the machine, and
    the usage pattern of the array. Heavily scattered writes
    are bound to be more expensive.
    RAID 10 (Mirrored Stripes) –A RAID 1 array of two RAID 0 arrays.
    † Strip Sizes:
    Select the desired strip size setting. As indicated, the optimal setting is 128KB. Se-
    lecting any other option may result in performance degradation. Even though 128KB
    is the recommended setting for most users, you should choose the strip size value
    which is best suited to your specific RAID usage model. The most typical strip size
    settings are:
    4KB: For specialized usage models requiring 4KB strips
    8KB: For specialized usage models requiring 8KB strips
    16KB: Best for sequential transfers
    32KB: Good for sequential transfers
    64KB: Good general purpose strip size
    128KB: Best performance for most desktops and workstations 
    						
    							5-18MS-7210 Micro-ATX Mainboard
    (3) Select Member Hard Drive(s)
    Then select the member disk (the target disk) that you wish to use and then
    click “--->” to move it to the Selected field. Then click Next to continue.
    Please note that the existing data on the selected hard drive(s) will be deleted
    permanently. Do not forget to back up all the important data before continuing. 
    						
    							5-19Introduction to Intel ICH7R SATA RAID(4) Specify Volume Size
    Specify the amount of available array space to be used by the new RAID
    volume. You may enter the amount in the space or use the slider to specify. It is
    recommended you use 100% of the available space for the optimized usage. For
    RAID 0 volume, if you do not specify 100% of the hard drive space, the rest hard
    drive space will be worked as RAID 1 volume, which is the new technology called
    Intel Matrix RAID. Then click Next to continue.(5) Start Creating RAID Volume from Existing Hard Drive Wizard
    Before you continue the procedure of RAID volume creation from existing
    hard drive, read the dialogue box below carefully. Please note that once you click
    Finish, the existing data on the selected hard drive(s) will be deleted permanently
    and this operation cannot be undone. It is critical that you backup all important data
    before selecting Finish to start the migration process. 
    						
    All MSI manuals Comments (0)