Appendix 47 Display toggles between “Error” and “buttn” A key is stuck or is being he ld down Check switches for damage Ensure that a remote is not co ntinuously transmitting Optional RF Remote display does not workUnits not mated See “Setting the Transmitter and Rece iver Address” procedures. Lo Batt is blinking Battery is low Replace (alkaline) or recharge batter ies Unit turns on, then i mmediately off Battery is low Replace (alkaline) or recharge batter ies Tension will not zero System not stable Wait for stable symbol to turn on Increase filtering for more stabi lity Zero out of range Zero range might be limited. Redu ce the tension or use tare instead Tension will not tare or tot al System is not stable Wait for stable symbol to turn on , or if in a mechanically noisy crane, increase the filtering or reduce the size of the Dyna- Link increment “d.” It is also possible to increase the motion window. Contact MSI if you have a problem getting the MSI-7300 to zero, tare, or total due to stability issues. Setpoint lights blink Setpoint is enabled and the tr igger point has been reached Disable setpoints if they are not nee ded Manual total does not work A function key is not set to “T otal” Set up Func1 or Func2 for “ Total” Tension must be stable Increase filtering for more stabi lity Auto total does not work Tension must be stable Wait for stable symbol to turn on, or incr ease filtering for more stability Tension thresholds not r eachedYou must exceed 1% of capacity for autototal to work. Then you must drop below 0.5% of capacity for additional weighments to register. ProblemPossible CauseSolution Table 7-1. Troubleshooting
48 MSI-7300 Operator’s Manual 7.2 Error Codes The ScaleCore processor that is the heart of the MSI-7300 Dyna-Link2 detects errors and generates error codes to aid in troubleshooting. Table 7-2. Error Codes Error CodeDefinitionComment LcOFF LC Disabled A load cell was not enabled 2CAL In Cal The system is in calibration mode. Do n ot send commands unrelated to calibration. unCAL Not Calibrated System has not been calibrated. Error LoadOverload Tension/Weight exceeds set capacity +9d Load Cell damaged or disconnected Error UnLd Underload Tension/Weight is more than 20% negati ve Load cell damaged or disconnected
Appendix 49 7. 3 5000 lbs / 2500 KGMAXIMUM CAPACITY 7300 lb B C = DIA. E = LOAD CELL BODY WIDTH AT SHACKLE INTERFACE.A D G F Mechanical Dimensions Figure 7-1. Mechanical Dimensions Table 7-3. Mechanical Dimensions CapacityABCDEFGApprox Shipping WtShackle 1000 lb8.0 in13.53 in.75 in5 in.99 in1.69 in1.75 in4.4 lbG-2130 3.25T 500 kg203 mm344 mm19 mm127 mm25 mm43 mm44.4 mm2.0 kg 2500 lb 8.5 in14.03 in.75 in5 in .99 in1.69 in 1.75 in 4.9 lb G-2130 3.25T 1250 kg 216 mm356 mm19 mm127 mm 25 mm43 mm 44.4 mm2.2 kg 5000 lb8.5 in14.03 in.75 in5 in.99 in1.69 in1.75 in4.9 lbG-2130 3.25T 2500 kg216 mm356 mm19 mm127 mm25 mm43 mm44.4 mm2.2 kg 10,000 lb 8.5 in16.14 in1 in5.50 in 1.35 in2.28 in 2.34 in 7.3 lb G-2130 6.5T 5000 kg 216 mm410 mm25 mm140 mm 34 mm58 mm 59.4 mm3.3 kg 25,000 lb9.5 in22.66 in1.63 in6.38 in2.24 in3.88 in4.69 in13 lbG-2130 17T 12,500 kg241 mm576 mm41 mm162 mm57 mm99 mm119 mm5.9 kg 50,000 lb 9.63 in25.67 in2 in7.50 in 2.74 in5.00 in 5.75 in 23 lb G-2130 25T 25,000 kg 245 mm652 mm51 mm191 mm 70 mm127 mm 146 mm10 kg 100,000 lb12 in29.75 in2.25 in8.13 in3.11 in5.75 in4.81 in53 lbG-2140 55T 50,000 kg305 mm756 mm57 mm207 mm79 mm146 mm122 mm24 kg
50 MSI-7300 Operator’s Manual 7.4 Firmware Update Procedure Updating firmware in the MSI-7300 requires the following: a DCE serial cable (MSI 503363-001, or build per DCE cable schematic on page 22), a PC with a terminal program (“Teraterm Pro” recommended), and if the PC does not have standard RS-232 serial ports, then a USB to serial converter. Make sure the driver for the USB converter is properly installed, and that the terminal program is set up for the proper comm port. The latest firmware code is available from the MSI service department and can be emailed on request. Your firmware version is displayed when the MSI-7300 is turned on in the form of “01-04” (your version will vary). Most firmware updates do not require a recallibration. Consult the versio n release notes for confirmation. 1. Setup the terminal serial port to 8 data bits, no parity, 1 stop bit, 9600 BAUD, XON/ XOFF (flo w control). 2. Connect to the Dyna-Link serial port using the DCE cable. Connect the D9 connector to your PC or USB adapter. 3. (Optional) Test that you have a connection by typing {00FF01?}. If the connection is good the Dyna-Link will respond with {000001r2;0;01E02;2011-07-08;11:05} or something similar. 4. On the terminal keyboard, type { ff0009 =0199} 5. Change the terminal serial port to 38400 BAUD. Hit the ‘q’ key to refresh the display . Cycle Power on MSI-7300 by removing and reinstalling batteries. The following menu should appear MSI-7300 SCALECORE 1 BOOT LOADER Ver. 02-04(c) 2011-09-02 17:06 (u) Download and program application code (q) query app code info (g) execute app code (r) refresh Your bootloader version may vary. 6. Type u Terminal should display: Send File NOW, or press ^ to abort: 7. Send the .prg file using the file send f eature of your terminal program. The character “#” will tick away as the ScaleCore programs. Send File NOW, or press ^to abort:##################################### ################################################################## ################################################################## ################################################################## ########################################################### Completed Note
Appendix 51 8. After the file is received, terminal should display “Completed.” Then the boot menu appears again. MSI8000 SCALECORE2 BOOT LOADER Ver. 02-04 (c) 2011-09-02 16:06 (u) Download and program application code (q) query app code info (g) execute app code (r) refresh 9. Optional step: send q to check the program. The S caleCore will respond with a message that details the 32b checksum, the product ID and version, and the application code version number in the following form: Computed Signature BOB742D Received Signature BOB742D Product ID 07 Dyna-Link product family Product Version ID 00 Optional features code App Code Version 01-04 Firmware version number If the CRC Signature does not match, go back to step 4 and try again. 10.Send an “ r” to restore the boot menu. MSI8000 SCALECORE2 BOOT LOADER Ver. 00-05 (c) 2012-05-02 10:55 (u) Download and program application code (your bootloader version may vary) (q) query app code info (g) execute app code (r) refresh 11.Send a “g.” The MSI-7300 should start. 32b CRC must match
52 MSI-7300 Operator’s Manual The MSI Limited Warranty MEASUREMENT SYSTEMS INTERNATIONAL , INC., WARRANTS load sensing elements and meters against defects in workma nship and materials for a period of one year from date of purchase and warr ants electrical cables and batteries against the same defects for a period of ninety (90) days from date of purchase. Any device which proves defective during the warr anty period will be replaced or repaired at no charge; provided that the defective devi ce is returned to the Company freight pre- paid. In no event shall the Company be liable for the cost of any repairs or alterations made by others except those repairs or alterations made with its specific written consent, nor shall the Company be liable for any damages or delays whether caused by defective workmanship, materials or otherwise. The Company shall not be liable for any personal injury or property damage resulting from the handling, possession or use of the equipment by the customer. The warranty set forth herein is exclusive and is expressly in lieu of all other warranties, express or implied, including without limitatio n any implied warranties of merchantability or fitness, or of any other obligations or liability on the part of the Company. The liability of the Company under this warranty is li mited solely to repairing or replacing its products during the warranty periods; an d the final judgment and disposition of all claims will be made by MEASUREMENT SYSTEMS INTERNATIONAL, INC.
A RICE LAKE WEIGHING SYSTEMS COMPANY Measurement SystemsInternationalTM 14240 Interurban Avenue South Suite 200 ”Seattle, WA 98168-4661 ”USA Phone: 206-433-0199 ”Fax: 206-244-8470 www.ricelake.com www.ricelake.mx www.ricelake.eu www.ricelake.co.i\ n m.ricelake.com © Rice Lake Weighing Systems 11/2013152160 Rev B