    							SECURENET Test Option
    Voice Mode System TestingVoice mode system testing provides
    SECURENETcompatible modulation anddemodulation with vocoding. Generate andmonitor modes support functional voice testingin the encrypted mode using either test keys
    stored in the R2670, or customerselected keys
    provided by a separate DX key loader. TheR2670 also emulates an AX, BX, or CX key
    loader, which can be used to download testkeys to a compatible radio.This feature allows verification of the proper
    operation and system compatibility using actual encryption algorithms.
    Bit Error Rate (BER) Testing
    Dedicated Test ScreensBER can be measured using the builtin 
    V.52 test pattern generator. This standard, nonencrypted pattern can be used to either modulate the Generator or inject into a radio or system under test via the baseband output.This BER pattern can then be recovered from
    the radio system either through the analyzer’sreceiver or from its baseband input to performa closed loop BER test. The BER test is also
    available in the unit’s Duplex mode.
    Conveniently accessed, dedicated test screens
    can be set up as a startup default condition ora programmable test setup. DedicatedSECURENET test screens are windowed with RF and Modulation control screens tosimultaneously display test results along withtheir test conditions. While in SECURENETmode, standard diagnostic test screens can be readily accessed.
    This testing provides an accurate, quantitative
    measurement of modulation quality and overallsystem performance. Loopback testing is supported while operating in Duplex mode.
    This feature makes testing easier and 
    more efficient. It also provides quantitative RF measurements to ensure proper system performance margin.
    Feature Description Benefits
    Available only in R2670
    11
    Specifications
                    
    						
    							AM/FM Monitor Cable Fault Locator
    AM/FM Generate Frequency Counter
    Audio Synthesizer Digital Voltmeter
    Spectrum Analyzer Wattmeter
    Duplex Generator Oscilloscope
    Sweep Generator Signal Strength Meter
    Tracking Generator SINAD/Distortion Meter
    FREQUENCY
    Range:400 kHz to 1 GHzResolution:50 HzAccuracy:Refer to Accuracy of Master OscillatorStabilization Time:.1 Second
    OUTPUT
    Range FM:130 dBm to 0 dBmRange AM:130 dBm to 3 dBm
    Accuracy:±2 dB, 80 dBm to 130 dBM, RF I/O Port
    ±4 dB, >3 MHz, all other levels and ports.
    SWEEP GENERATOR
    Range:400 kHz to 1 GHzResolution:50 HzOutput:130 dBm to 0 dBmSweep Width:Selectable up to ±5 MHz of center freq.Scope Coupling:Synchronized scope trace to the 
    sweep signal
    Accuracy:Same as Signal Generator
    DUPLEX GENERATOR
    Range:400 kHz to 1 GHzReceiver Resolution:50 HzOutput:130 dBm to 0 dBmFrequency Offset0 MHz to ±999.995 MHz in 2.5 kHz stepsAccuracy:Same as Signal Generator
    SPECTRAL PURITY
    Spurious:35 dBc within ±20 MHz of selected 
    carrier frequency. Additional fixed 
    spurs at an absolute level of 
    						
    							ASTRO (Optional Feature)
    Voice Testing:ASTRO compatible vocoder for 
    both generator and receiver provides functional voice testing capability via internal speaker and microphone 
    accessory. Scope display of voice waveform can also be selected.
    EMBEDDEDLink Control Field (LCF)SIGNALINGPresentation Address (PA)Encode Capability:Key ID
    Network IDBusy Bits
    Encode
    Operator Entry:A default configuration can be selected 
    or a detailed special screen can be accessed for customized programming.
    Decoding Operation:A dedicated screen may be selected to 
    display and decode the same data as described in the encode section. The unit can also buffer 30 frames of data on a firstin/firstout basis with the capability to selectively recall any of the stored frames to the screen.
    BER Capability:Free running, unframed V.52 pseudo 
    random nonencrypted sequence compatible with ASTRO test mode. Measurement range from 0 to 20% bit errors.
    Encryption Capability:DVPXL, DESXL, DVIXL. For each 
    of these algorithms, the unit can accept customer keys from Motorola external key loaders (DXCompatible).
    ASTRO single key software encryption is 
    also supported. A single side connector is provided for key loading.
    Generate Capability:ASTRO Voice Frames containing both 
    VSELP vocoded voice and embedded 
    signaling or an unframed V.52 pseudo random nonencrypted sequence.
    Monitor Capability:ASTRO Voice Frames containing both 
    VSELP vocoded voice and embedded 
    signaling or an unframed V.52 pseudo random nonencrypted sequence.
    Duplex Capability:An unframed V.52 pseudo random 
    nonencrypted sequence.
    Project 25 Conventional (Optional Feature)
    Voice Testing:Project 25compatible IMBE vocoder 
    for both generator and receiver provides functional voice testing capability via internal speaker and 
    microphone accessory. Scope display of voice waveform can also be selected.
    EMBEDDED
    SIGNALING
    Encode Capability:
    Link Control Field (LCF)
    Low Speed Data (LSD)Key IDNetwork IDStatus Symbol
    Encode Operator Entry:A default configuration can be selected 
    or a detailed special screen can be accessed for customized programming.
    Decoding Operation:A dedicated screen may be selected to 
    display and decode the same data as described in the encode section. The unit can also buffer 30 frames of data on a firstin/firstout basis with the capability to selectively recall any of the stored frames to the screen.
    BER Capability:Compute BER from received non
    encrypted 1011 Hz tone test pattern. Generate nonencrypted 1011 Hz tone test pattern or a calibration test pattern (generates 4.977% BER)for UUT BER calculation with Project 25 test mode.
    Encryption Capability:AES, DESOFB, DVPXL, DESXL, DVIXL.For each of these algorithms, the unit 
    can accept customer keys from Motorola external key loaders (DX compatible).A single side connector is provided for key loading.
    Generate Capability:Project 25 Standard Voice Frames 
    containing both IMBE vocoded voice and embedded signaling, a standard 1011 Hz tone test pattern, a calibration test pattern and a standard silence test pattern.
    Monitor Capability:Either Project 25 Standard Voice 
    Frames containing IMBE vocoded voice and embedded signaling or a standard 1011 Hz tone test pattern.
    Project 25 Trunking (Optional Feature)
    Call Sequence Tests:Registration/Call Alert
    Dispatch Voice
    Project 25 Trunking
    Test Parameter Entries:WACN ID, System ID, WUID (or UID),
    WGID (or GID), RFSS ID, Site ID, IDEN_UP
    Test measurement display:Call sequence status indicator
    WACN ID, System ID, UID, GID, WUID, WGID
    Frequency Bands:800MHz – 851.00625MHz – 876.59375MHz)
    with a 45Mhz offset. Channel plan #1.
    700MHz – 762.00625MHz – 787.59375MHz)
    with a +30MHz offset. Channel plan #2.
    UHF/VHF – Userdefined channel plan. 
    The channel plan range is 1 thru 16. This can also be used to define nonstandard 700MHz channel plans.
    Generate 
    Deviation Selection:0.00kHz – 5.00kHzBase Station Tests:Full duplex modulation of 1011 Hz test 
    pattern with simultaneous C4FM/LSM demodulation of voice. Also includes an averaging wattmeter with selectable period (.09 sec to 4.32 sec) and an 
    accuracy of ±15%. Input range is from 
    .5 watts to 125 watts peak.
    BER Capability:Free running, unframed V.52 pseudo 
    random nonencrypted sequence.Measurement range from 0 to 20% bit errors.
    T
    runking (Cont.)
    Trunking Test
    Parameter Entries:(Dependent on Test Selection)
    Signaling TypeCall SequenceSystem IDSize Code
    Connect ToneFrequency Band
    Control and Traffic Channel (by frequency and channel number)
    Test Measurement
    Display:Call Sequence Status Indicator
    Radio ID (Hex or Decimal)
    Call TypeRF Performance Data (via exit to standard screens)
    Radio ID Decoding:Type I: Fleet, Subfleet & Unit ID 
    Type II: Talk Group, Unit ID
    Smart Zone
    Test Support:Auto affiliation test
    Frequency Bands:851870 MHz, 866870 MHz Split 
    Channel935941 MHz, 850860 MHz JSMR
    403522 MHz UHF, 132175 MHz VHF
    Generate Deviation
    Selection:1.2 kHz, 2.4 kHz, 3.125 kHz
    Type I System
    Configuration Storage:Nonvolatile storage of up to 10 fleet 
    maps with alpha numeric entries
    Channel Plan
    Entry for VHF/UHF:Separate transmitter and receiver 
    startandend frequency for three blocks. Independent channel spacing for each block.
    DIAGNOSTIC OPTIONS
    13
                                                                                                             
    						
    							SPECTRUM ANALYZER
    Frequency Range:400 kHz to 1 GHzDispersion:Selectable from keypad, as follows:
    200 kHz window  (20 kHz per division)500 kHz window  (50 kHz per division)1 MHz window  (100 kHz per division)2 MHz window  (200 kHz per division)5 MHz window  (500 kHz per division)10 MHz window  (1 MHz per division)20 MHz window  (2 MHz per division)50 MHz window  (5 MHz per division)100 MHz window  (10 MHz per division)
    Dynamic Range:60 dBBandwidth:Automatically selected:
    6 kHz  (100 kHz per division & below) 30 kHz  (200 kHz per division & above)
    Display Range:+50 to 95 dBmModes:Freeze, Max Hold, Peak Hold, 
    Average
    Markers:Delta or Absolute Level and Frequency
    SIGNAL STRENGTH
    INDICATOR
    Range:
    400 KHz to 1 GHzAccuracy:±4 dB, >3 MHzSensitivity:100 dBm (antenna port rating)
    WATTMETER
    (RF I/O PORT)
    Frequency Range:
    400 KHz to 1 GHzMeasurement Range:.1 watt to 125 wattsInput Impedance:50 ohms with maximum VSWR of 1.5:1Accuracy:±10%, >3 MHzProtection:Over temperature alarms
    TRACKING GENERATOR*
    Frequency Range:400 kHz to 1 GHzTracking Display
    Sweep Range:200 kHz window  (20 kHz per division)
    500 kHz window  (50 kHz per division)1 MHz window  (100 kHz per division)2 MHz window  (200 kHz per division)5 MHz window  (500 kHz per division)10 MHz window  (1 MHz per division)20 MHz window  (2 MHz per division)50 MHz window  (5 MHz per division)
    Display Range:0 to 80 dBm
    CABLE FAULT*
    Method:Standing Wave AnalysisMeasure:Fault distance, cable lengthReading:Feet and metersAccuracy:±10%
    Metering & Measur
    ement (Cont.)
    OSCILLOSCOPE
    Display Size:6.4 in (17 cm) diagonalFrequency
    Response:0 to 50 kHzVertical Input
    Ranges:Selectable per the following:
    10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 
    500 mV, 1v, 2v, 5v, 10v per division
    Accuracy:5% of full scale all ranges
    Sweep Ranges:Selectable per the following:
    20 usec, 50 usec, 100 usec, 200 usec, 500 usec, 1 msec, 2 msec, 5 msec, 10 msec, 20 msec, 50 msec, 100 msec, 200 msec, 500 msec, 1 sec per division
    Trigger:Automatic, normal, and single sweepMarkers:Delta Voltage, Delta Frequency, 
    Delta Period
    DIGITAL VOLTMETER
    Meter Type:RMSFrequency Range:DC plus AC of 50 Hz to 20 kHzDC Voltage Ranges:1.0 V, 10.0 V, 100.0 V full scaleAccuracy:1% full scale ±1 least significant digitAC Voltage Ranges:1.0 V, 10.0 V, 70.0 V full scaleAccuracy:5% full scale ±1 least significant digitFreq. Response:3 dB end points @ 50 Hz and 20 kHz
    FREQUENCY COUNTER
    Frequency Range:5 Hz to 500 kHz plus Auto TunePeriod Counter
    Range:5 Hz to 20 kHzInput Level:0.1 v RMS minimum input levelResolution:0.1 Hz, 1 Hz and 10 Hz
    varying by frequency range
    Auto Tune:Monitor mode, 20 MHz to 1 GHz, unit 
    will scan and find signals greater than 30 dBm
    Accuracy:See TIME BASE
    SINAD/DISTORTION
    METER
    Input Level:
    0.1 V to 10 V RMSSINAD Accuracy:±1 dB at 12 dB SINADDistortion Range:1% to 20%Distortion Accuracy:±0.5% of distortion or ±10% of reading 
    whichever is greater
    Optional:CMessage Filter; CCITT Filter 
    w/ 600 ohm switchable load
    TONE SEQUENCE
    DECODE
    Modulation types:
    PRIVATE LINE, DIGITAL PRIVATE 
    LINE, Single Tone, DTMF, TwoTone 
    Paging, 5/6 Tone Paging, International Select V, 20 Tone General Sequence.
    Frequency Accuracy:±3% from 300 Hz to 3 kHzDuration Accuracy:±12 msec for tones greater than 
    30 msec and 300 Hz
    RS232 PORTBidirectional port provided with capability to respond to serial 
    input command vocabulary to activate standard functions and return measured results. Baud rates to 115.2 Kbps with selectable start, stop and parity bits.
    TIME BASE:Aging .5 ppm/yr, 
    Temperature .05 ppm
    14
    SECURENET (Optional Featur
    e)
    Voice Testing:SECURENET compatible vocoder for 
    both generator and receiver provides functional voice testing capability via internal speaker and microphone 
    accessory. Scope display of voice waveform can also be selected.
    Encryption Capability:DVPXL, DES, DESXL, DVIXL
    For each of these algorithms, the unit can emulate an AX, BX or CXtype key loader to load test keys to a compatibleradio. It can accept actual keys from Motorola external key loaders. A single side connector is provided for key loading.
    End of Message Test:The signaling tone that terminates 
    a SECURENET transmission can be 
    detected and displayed to the operator.
    BER Capability:Free running, unframed V.52 pseudo 
    random nonencrypted sequence.Measurement range from 0 to 20% bit errors.
    Printer/Remote
    Control:RS232 DB25 (female)Color Monitor:Standard 15 pin VGA
    AC:100 to 130 VRMS or 200 to 260 VRMS 
    @ 50 Hz to 440 Hz
    DC:+11 to +16 VDC (10A Fused)Battery Option:13.6 V, 50 minutes typicalDimensions:8.5” high x 16” wide x 17” deep
    (21.6 cm x 40.7 cm wide x 43.2 cm) excluding accessories, battery pack and cover
    Weight:28.5 lbs., base unit without cover, options 
    or accessories
    Temperature:0° C to +50° C (operating)
    40°C to +85° C (storage)
    INTERFACE PORTS
    POWER & ENVIRONMENT
    METERING & MEASUREMENT
                                                                                                                                                                                                    
    						
    							Base Models:
    R2600D Standard Unit for general purpose 2way testing
    R2625B Standard Unit configured for Project 25 Test Capability, including DESOFB encryption
    R2670B Enhanced Standard Unit for ASTRO, Project 25, SMARTNET/SmartZone, and/or SECURENET test options
    Options Matrix (Order as additional Line items with base Model)
    Standard OptionsModel Availability
    DescriptionPart NumberR2600R2625R2670NotesTracking Generator RLN5069 Optional OptionalStandardCable Fault RLN4306 Optional OptionalStandardIncludes RF Detector Probe and ‘T’ 
    Programmable Test Setup Memory RLN4485 Optional OptionalStandardIEEE 488.2 Remote InterfaceRLN4329 Optional Optional Optional
    CMessage Filter with 600 ohm load RLN4034 Optional Optional Optional
    CCITT Filter with 600 ohm load RLN4361 Optional Optional Optional
    Phase Mod/Demod RLN4484 Optional Optional Optional
    Analog Trunking Options – Select Only OneSMARTNET/SmartZone RLN4498 NA NA Optional
    SMARTNET/SmartZone
    with ASTRO trunking RLN4497 NA NA Optional VSELP/IMBE Compatible
    Diagnostic Test OptionsOrder CM701 plus desired transmission format(s) and applicable encryptionConventional Hardware Module CM701 NA NA Optional
    Transmission Formats – Select any combinationMust also include CM701Securenet CM711 NA NA Optional Requires Compatible Encryption Option
    ASTRO CM712 NA NA Optional VSELP Vocoder
    Project 25 with DESOFB encryptionCM713NAStandardOptional IMBE Vocoder
    Project 25 Trunking CM714 NA Optional Optional Support for 9600 Baud CC trunking and OBT. 
    Requires CM713
    Encryption Options – Select any combination(Requires CM711, CM712, or CM713)AESCM707NA Optional Optional Compatible w/Project 25
    DES, DESXL CM708 NA Optional Optional Compatible w/Project 25, ASTRO, SECURENETDVPXLCM709 NAOptionalOptionalCompatible w/Project 25, ASTRO, SECURENET
    DVIXLCM710 NA Optional Optional Compatible w/Project 25, ASTRO, SECURENET
    Accessories Supplied – May also be ordered separatelyOscilloscope ProbeRTL4011A***
    BNC to N Adapter5884300A98***
    DC Power Connection Kit RPX4097A * * *
    Telescoping AntennaTSBN***
    90 Degree BNC for AntennaM55339/14003***
    MicrophoneHMN1056D * * *
    Signal Generator Termination 
    (50 ohm)5880386B73 * * *
    Operators Manual (on CD) *6880386B72 *6880309J83 *6880309F17
    Power Cord 3080397A62 * * *
    Spare RF Fuses GG6530277C002 * * *
    BNC RF ‘T’ 0982578B01 * Required for cable fault testing
    RF Detector Probe RLN4748A * Required for cable fault testing
    Additional Accessories – Order Separately
    Battery Pack RPN4000A Affixes to back of unit
    Canvas Carrying Case 1580357B77 Protects unit when used in the field
    Hard sided transit case A001 Shipping protection
    Hard sided transit case w/wheels A002 Shipping protectionIsolation transformer
    for baseband output 0180302E83 Isolate output signal
    Isolation transformerfrom chassis ground
    for baseband input 0180302E82 Isolate input signal
    RF Detector probe with 50 ohm  from chassis ground
    termination 5880345B96
    Programmers Reference Manual 6880309E55 Includes RS232 and IEEE 488.2
    Service Manual on CD RLN5237A
    15
    Model Nomenclature and Ordering Guide
    NA – Option Not Available
    *Accessory Included with model
                                            
    						
    							8201 E. McDowell Road Scottsdale, AZ 85252 • Please call the General Dynamics representative in your area for assistance 
    with product information, pricing and orders. In the United States • Telephone: 8774490600 (Toll Free) • FAX: 4804417169
    Web Site: www.gdds.com/cte
    R2600 Series Communications System Analyzers
    Service, maintenance 
    and technical support
    All trademarks indicated as such herein are trademarks of General
    Dynamics ® Reg. U.S. Pat. &Tm. Off. All other product or service names
    are the property of their respective owners. © 2003 General Dynamics. 
    All rights reserved. General Dynamics reserves the right to make changes
    in its products and specifications at any time and without notice.
    For support on General Dynamics test equipment contact:
    United States and Canada:
    Motorola Test Equipment Service Center
    2216 Galvin Drive
    Elgin, IL 60123
    Phone: 8003236967
    Europe, the Middle East, and Africa:
    Motorola Test Equipment Service Center
    HeinrichHertz Strasse 165232 TaunussteinNeuhof
    Phone:  +496128700
    Asia and the Pacific Rim (excluding Japan):
    Motorola Electronics Pte Ltd
    Motorola Innovation Centre, CGISS7th Floor
    12 Ang Mo Kio Street 64Ang Mo Kio Industrial Park 3Singapore 569088Phone: +6564863256Fax: +6564863257
    Japan:
    Nextec Japan Ltd
    32422 KitaYamada
    Tsuzukiku
    Yokohama, Japan 224
    Phone:  +810454102287Fax:  +810455920994
    Australia and New Zealand:
    Australian Support Center
    Motorola Australia Pty Ltd
    10 Wesley Court
    Tally Ho Business Park
    East Burwood, VIC  3151AustraliaPhone:  +61398477725Fax:  +61398477755
    Service is also available in other areas around the world. Please contact your local 
    General Dynamics sales or service representative for the facility nearest you.
    BR260030604
                                  
    						
    All Motorola manuals Comments (1)