Page 21
Introduction: Specifications 1-11 UHF1 Self-Quieter Frequencies GPS Non-GPS 403.20 MHz ± 5k 409.23 MHz ± 5k – 414.00 MHz 417.79 MHz ± 10k 420.00 MHz ± 5k 425.60 MHz ± 5k – 431.10 MHz ± 5k 432.00 MHz ± 5k 436.80 MHz ± 5k 441.97 MHz ± 5k – 442.36 MHz ± 10k 444.00 MHz ± 5k 450.00 MHz 453.60 MHz ± 5k 458.34 MHz ± 5k – 466.93 MHz ± 10k 468.00 MHz ± 5k VHF Self-Quieter Frequencies GPS Non-GPS 144.000 MHz ± 100k 147.320 MHz ± 5k – 147.455 MHz ± 10k 151.200 MHz ± 5k 156.000 MHz ± 10k 162.000 MHz ± 10k 163.690...
Page 22
1-12Introduction: Specifications UHF2 Self-Quieter Frequencies GPS Non-GPS 450.000 MHz 453.600 MHz ± 5k 458.340 MHz ± 5k – 466.930 MHz ± 10k 468.000 MHz ± 5k 470.400 MHz ± 5k 474.701 MHz ± 10k – 480.000 MHz ± 5k 486.000 MHz ± 15k 487.200 MHz ± 5k 491.070 MHz ± 10k – 491.520 MHz ± 10k 502.200 MHz ± 5k 504.000 MHz ± 15k 506.695 MHz ± 5k 507.439 MHz ± 15k –
Page 23
Introduction: Specifications 1-13 GPSDisplay DP 3600/ DP 3601Non-Display DP 3400/ DP 3401 TTFF (Time To First Fix) Cold Start < 1 minute TTFF (Time To First Fix) Hot Start < 10 seconds Horizontal Accuracy < 10 meters Accuracy specs are for long-term tracking (95th percen tile values > 5 satellites visible at a nominal -130 dBm signal strength) Military Standards Applicable MIL–STD 810E 810F Methods Procedures Methods Procedures Low Pressure 500.3 II 500.4 II High Temperature 501.3...
Page 24
1-14Introduction: Specifications * -Operating temperature specification with LiIon battery is -10°C to +60°C. -Operating temperature specification with NiMH battery is -20°C to +60°C. Conforms to: MOTOTRBO Portable series radios meet FM (Facto ry Mutual) standards for intrinsic safety used in Class I, II, III, Division 1, Groups C, D, E, F, and G when properly equipped with a Motorola FM approved battery option. They are also approved for nonincendive use in Class I, Division 2, Groups A, B, C, and...
Page 25
Chapter 2 Test Equipment and Service Aids 2.1 Recommended Test Equipment The list of equipment contained in Table 2-1 includes most of the standard test equipment required for servicing Motorola portable radios. Table 2-1. Recommended Test Equipment Equipment Characteristics ExampleApplication Service MonitorCan be used as a substi- tute for items marked with an asterisk (*)Aeroflex 2975 (www.aeroflex.com), Motorola R2670, or equivalentFrequency/deviation meter and signal generator for wide-range...
Page 26
2-2Test Equipment and Service Aids: Service Aids 2.2 Service Aids Table 2-2 lists the service aids recommended for wo rking on the radio. While all of these items are available from Motorola, most are standard worksh op equipment items, and any equivalent item capable of the same performance may be substituted for the item listed. Table 2-2. Service Aids Motorola Part No. Description Application RLN4460_Portable Test SetEnables connection to the audio/accessory jack. Allows switching for radio...
Page 27
Test Equipment and Service Aids: Programming, Testing and Alignment Cable 2-3 2.3 Programming, Testing and Alignment Cable Figure 2-1. Programming, Testing and Alignment Cable #1 #14 #25 #13 #4 #1 #2 #12 #11 #1P1 P2 P3
Page 28
2-4Test Equipment and Service Aids: Programming, Testing and Alignment Cable Figure 2-2. Pin Layout of Side Connector Table 2-3. Pin Configuration of Side Connector CONNECTION P1 P2 P3 Pin Pin Pin Function 13 VCC (5V) 34D ATA + 25D ATA - 16 6 GROUND 7 8 SPEAKER - 17 10 EXTERNAL MIC + 16 11 EXTERNAL MIC - 20 9 EXTERNAL PTT 1 7 SPEAKER + 41 (Coax Connector) GROUND slot for accessory connector hook Coaxial RF Connector 1 2 3 4 5 6 7 8 9 10 11 12 GPI O_0 Spkr + Spkr - Mic + Mic - GPI O_3 GPI O_4...
Page 29
Chapter 3 Transceiver Performance Testing 3.1 General These radios meet published specifications through their manu facturing process by utilizing high- accuracy laboratory-quality test equipment. Th e recommended field service equipment approaches the accuracy of the manufacturing equipment with few exceptions. This accuracy must be maintained in compliance with the manufacturer’s recommended calibration schedule. Although these radios function in digital and a nalog modes, all testing is done in...
Page 30
3-2Transceiver Performance Testing Setup Oscilloscope Source: Mod Oscilloscope Horizontal: 10mSec/Div Oscilloscope Vertical: 2.5kHz/Div Oscilloscope Trigger: Auto Monitor Image: Hi Monitor Bandwidth: Narrow Monitor Squelch: Middle setting Monitor Vol: 1/4 setting Current: 2.5A Table 3-1. Initial Equipment Control Settings Service Monitor Power Supply Test Set