    Your monitor can be connected to a LAN allowing you to 
    control it from a PC on the LAN. 
    You can also confi gure the monitor to send e-mail notifi cation 
    when it has a problem. 
    The connection requires a commercially available LAN cable 
    (UTP cable, Category 5, straight through).
    Hub  LAN terminal 
    LAN cable (commercially available, straight) 
    Network (LAN) 
    TIPS
    •  You must assign an IP address to the monitor by following 
    the procedures in “Settings to connect to a LAN”. (See the 
    description on the right.)
    •  Your PC must be installed with Internet Explorer (version 6.0 
    or later). 
    •   To control the monitor via LAN, set RS-232C/LAN SELECT 
    to LAN. (See page 7.)
    •  You cannot use RS-232C and LAN control simultaneously. 
    Controlling the Monitor with a PC (LAN)
    Settings to connect to a LAN
    Set the monitor’s IP address and subnet mask to match the 
    settings of your LAN. 
    These settings can be made on either the monitor or a PC 
    connected to the monitor.
    The settings depend on the confi guration of your LAN. Ask 
    your LAN administrator for details. 
    „ To set on the monitor
    Set RS-232C/LAN SELECT on the SETUP menu to LAN, and 
    then set the LAN SETUP options. (See page 7.)
    After setting each item, select SET and press 
    MENU.
    DHCP CLIENT
    If your LAN has a DHCP server and you wish to obtain an 
    address automatically, change this setting to ON. 
    To set the address manually, set this to OFF. 
    IP ADDRESS
    If the DHCP CLIENT is set to OFF, specify an IP address. 
    Press 
     or   to select items, and press  or  to 
    change the values.
    SUBNET MASK
    If the DHCP CLIENT is set to OFF, specify the subnet mask. 
    Press 
     or   to select items, and press  or  to 
    change the values.
    DEFAULT GATEWAY
    If the DHCP CLIENT is set to OFF, specify the default 
    gateway. 
    If you are not using a gateway, specify “0.0.0.0”. 
    Press 
     or   to select items, and press  or  to 
    change the values.
    RESET
    Resets the values of the LAN settings to the factory preset 
    values. 
    Select ON and then press 
    MENU.
     
    						
    							22E22
    „ To set from a PC
    When the monitor is connected to a PC, LAN settings can be 
    confi gured via PC. 
    Set up process
    (1) Connect your monitor to a PC
    (2) Specify the PC’s IP address
    (3) Confi gure the monitor’s LAN settings
    (1) Connecting your monitor to a PC
    Connect a commercially available crossover LAN cable 
    (UPT cable, Category 5) to the LAN  port on the PC and this 
    monitor.
    LAN cable (commercially available, crossover) 
    To LAN terminal PC  LAN terminal
    (2) Specifying the PC’s IP address
    To confi gure the monitor’s LAN settings, you must temporarily 
    change the settings on the PC. 
    This explanation is based on Windows XP.
    1.  Log on to the PC with an administrator account. 
    2.  Click [Start], and then click “Control Panel”.
    3.  Click “Network and Internet Connections”, and then click 
    “Network Connections”. 
    If you are using the classic display style, double-click on 
    “Network Connections”.
    4.  Right click on “Local Area Connection” and from the menu, 
    click “Properties”.
    5.  Click “Internet Protocol (TCP/IP)”, and then click 
    “Properties”.
    6.  Make a note of the current IP address, subnet mask, and 
    default gateway settings. 
    Make sure you write this information now as you will 
    be changing the IP address, subnet mask, and default 
    gateway settings back to these settings afterwards. 7.  Temporarily change the IP address and subnet mask. 
    To access the monitor as it is shipped from the factory, set 
    as follows. 
    • IP Address: 192.168.150.3
    •  Subnet Mask: 255.255.255.0
    •  Default Gateway: (leave blank)
    8.  Click [OK] and then reboot the PC.
    TIPS
    •  This monitor is factory preset as shown below. 
     IP Address  : 192.168.150.2
      Subnet Mask  : 255.255.255.0
      Default Gateway  : 0.0.0.0
    (3) Confi guring the monitor’s LAN settings
    Access the monitor using Internet Explorer. 
    Controlling the monitor
    1.  Turn the power ON to the monitor.
    2.  Set RS-232C/LAN SELECT on the SETUP menu to LAN. 
    PC operation
    3.  Launch Internet Explorer, in the “Address” box type 
    “http://192.168.150.2/” and press the Enter key. 
    You will be prompted to enter a user name and password. 
    4.  Leave the user name and password boxes blank and click 
    [OK]. 
    Controlling the Monitor with a PC (LAN)
     
    						
    							23E23
    5.  Click on “LAN SETUP” under NETWORK. 
    6.  Specify the “DHCP CLIENT”, “IP ADDRESS”,etc. 
    DHCP CLIENT
    If your LAN has a DHCP server and you wish to obtain an 
    address automatically, change this setting to “ON”. 
    To set the address manually, set this to “OFF”. 
    IP ADDRESS
    If the DHCP CLIENT is set to “OFF”, specify an IP 
    address.
    SUBNET MASK
    If the DHCP CLIENT is set to “OFF”, specify the subnet 
    mask.
    DEFAULT GATEWAY
    If the DHCP CLIENT is set to “OFF”, specify the default 
    gateway.
    If you are not using a default gateway, specify “0.0.0.0”.
    7.  When the setting is changed, click [Apply].
    8.  Check the message and click [OK].
    9.  Exit Internet Explorer. 
    10. Restore the PC’s IP address jotted in Step 6, “(2)  Specifying the PC’s IP address”. 
    11 . Connect the monitor and the PC to the LAN.
    Caution
    •  Wait 10 seconds after clicking [OK] before proceeding.
    •  When operating using the remote control unit or similar,  click [Refresh].
    Controlling with a PC
    „  Basic operation
    You use Internet Explorer on a PC on the LAN  to control the 
    monitor.
    1.  Launch Internet Explorer on the PC.
    2. 
    In the “Address” box, type “http://” followed by your monito\
    r’s 
    IP address followed by “/”, then press the Enter key.
    When prompted to enter a user name and password, type 
    the user name and password that you speci fi ed in the 
    security settings (see page 25), and click [OK].
    If you did not make any security settings, leave the spaces 
    blank and click on [OK]. 
    3.  You can check, control, and change the monitor’s status  and settings by clicking the menu items on the left side of 
    the screen. 
    •  If you see an [Apply] button next to a setting, click it after you change that setting.
    TIPS
    •  See pages 24 to 28 for details on each setting. 
    •  If you click [Refresh] before the screen fi  nishes updating 
    the current display, the “Server Busy Error” will appear. 
    Wait for a moment before operating your monitor again. 
    •  You cannot operate the monitor while it is warming up. 
    •  If “DHCP CLIENT” is set to “ON”, press 
    DISPLAY on the 
    remote control unit two times and then check the monitor’s 
    IP address. 
    Controlling the Monitor with a PC (LAN)
     
    						
    							24E24
    „ INFORMATION
    Information about this monitor appears. 
    „ CONTROL
    You can control the operations corresponding to the buttons 
    (POWER INPUT SIZE) on the remote control unit. (See page 3.)
    TIPS
    •  In standby mode, Power ON is the operation available.
    „ ADJUSTMENT
    You can adjust these settings which are also available on the 
    monitor’s menu. 
    •  SCREEN (See page 6.)
    •  PICTURE (See Page 6.)
    •  PICTURE (ADVANCED) (See Page 6.)
    •  AUDIO (See page 6.)
    •  SETUP (See page 7.)
    •  OPTION (See page 7.)
    •  SCHEDULE (See page 9.)
    •  ENLARGE (See page 9.)
    •  PIP/PbyP (See page 8.)
    •  FUNCTION (See page 11.)
    Controlling the Monitor with a PC (LAN)
     
    						
    							25E25
    „ NETWORK (LAN SETUP)
    This screen allows you to set the settings necessary when the 
    monitor is connected to a LAN.
    DHCP CLIENT
    If your LAN has a DHCP server and you wish to obtain an 
    address automatically, change this setting to “ON”. 
    To set the address manually, set this to “OFF”. 
    IP ADDRESS
    If the DHCP CLIENT is set to “OFF”, specify an IP address.
    SUBNET MASK
    If the DHCP CLIENT is set to “OFF”, specify the subnet 
    mask.
    DEFAULT GATEWAY
    If the DHCP CLIENT is set to “OFF”, specify the default 
    gateway.
    If you are not using a default gateway, specify “0.0.0.0”.
    DNS SERVER
    Specify the DNS server address. 
    If you are not using a DNS server, specify “0.0.0.0”. 
    RESET
    Clicking [Execute] returns all of the LAN SETUP settings 
    to the factory-preset values except for the DNS SERVER 
    setting.
    „ NETWORK (SECURITY)
    This screen allows you to specify the security-related settings.
    USER NAME / PASSWORD
    Sets up a user name and password to restrict access to this 
    monitor. 
    After entering a user name and password, click [Apply].
    ACCEPT IP ADDRESS
    You can limit access to this monitor by registering IP 
    addresses of PCs that should have access. 
    To limit access, specify the option “From only specifi c IP 
    addresses”. Otherwise, to allow access from any PC, specify 
    “All IP Addresses”.
    IP ADDRESS 1 to 3
    If “ACCEPT IP ADDRESS” is set to “From only specifi c IP 
    addresses”, enter the IP addresses that you want to allow. 
    TIPS
    •  The USER NAME and PASSWORD can be up to 8 
    alphanumeric characters or symbols.  
    •  To cancel the user name and/or password after it has been 
    set, make the box empty and click [Apply]. 
    Controlling the Monitor with a PC (LAN)
     
    						
    							26E26
    „ NETWORK (GENERAL)
    This screen allows you to specify the general LAN settings.
    MONITOR NAME
    Specify a name for this monitor as it should appear on the 
    Internet Explorer screen.
    AUTO LOGOUT TIME
    Specify the time (in minutes) to elapse before automatically 
    disconnecting this monitor from the network. 
    Specify in minutes from 1 to 65535. A value of ‘0’ will disable 
    this function. 
    DATA PORT
    Specify the TCP port number to use for exchanging data with 
    the monitor. 
    Specify a value from 1025 to 65535.
    SEARCH PORT
    Specify the port number to use when searching for this 
    monitor. 
    Specify a value from 1025 to 65535.
    TIPS
    •  The MONITOR NAME can be up to 16 alphanumeric 
    characters or symbols. 
    „ MAIL (ORIGINATOR) 
    This screen allows you to confi
     gure the e-mail sent periodically 
    or when the monitor has an error.
    The settings depend on the con fi guration of your LAN. Ask 
    your LAN administrator for details. 
    SMTP SERVER
    Specify the SMTP server address for sending e-mail.  *  When using a domain name, make sure to specify the  DNS server as well. (See page 25.)
    ORIGINATOR E-MAIL ADDRESS
    Specify the e-mail address for this monitor. 
    This address becomes the e-mail address of the originator. 
    ORIGINATOR NAME
    Specify the name for the originator. 
    This name appears in the “Originator Name”  fi eld of the 
    e-mail.
    AUTHENTICATION
    Specify the authentication method to use when sending 
    e-mail. 
    POP SERVER
    If the “AUTHENTICATION” method is “POP before SMTP”, 
    specify the POP server address. 
    ACCOUNT NAME / PASSWORD
    If the “AUTHENTICATION” method is “POP before SMTP”, 
    specify the account name and password to connect to the 
    POP server.  
    TIPS
    •  You can enter up to 64 alphanumeric characters or symbols  for the ORIGINATOR E-MAIL ADDRESS, ORIGINATOR 
    NAME, ACCOUNT NAME, and PASSWORD. 
    •  The SMTP SERVER and POP SERVER can be up to 64  characters. The following characters can be used: a-z, A-Z, 0-9, - , .
    Controlling the Monitor with a PC (LAN)
     
    						
    							27E27
    „ MAIL (RECIPIENT) 
    This screen allows you to specify the recipients of the e-mail 
    sent periodically or when the monitor has an error.
    RECIPIENT E-MAIL ADDRESSES
    Specify the e-mail addresses to send error notifi cation e-mail 
    to.
    CONDITION
    Specify the conditions to send mails.
    When you check PERIODICAL, specify the date and time to 
    send the mails in the PERIODICAL setting.
    CONFIRMATION
    Sends test e-mail.
    This allows you to confi rm that the e-mail settings are 
    confi gured properly.
    Attach the log fi le to a TEMPERATURE/HARDWARE error 
    e-mail
    When this option is checked, a log is added to the mail which 
    notifi es a temperature or status error.
    TIPS
    •  The RECIPIENT E-MAIL ADDRESSES can be up to 64 
    alphanumeric characters or symbols. 
    Controlling the Monitor with a PC (LAN)
    „ MAIL (PERIODICAL)
    When PERIODICAL for CONDITION of MAIL (RECIPIENT) is 
    checked, set the date and time to send the mail.
    DAY OF THE WEEK
    Specify the day of the week to send the periodical mails.
    TIME
    Specify the time of the day to send the periodical mails.
    Caution
    •  Do not turn off the main power when you set to send the 
    periodical mails.
    •  Specify the correct date and time. (See page 7.) 
    If the date and time settings are incorrect, the periodical 
    mail is not sent properly.
    • Regularly confi rm that the specifi ed date and time is 
    correct.
     
    						
    							28E28
    Controlling the Monitor with a PC (LAN)
    „   SERVICE & SUPPORT 
    (URL INFORMATION)
    You can display a speci fi c URL in the URL INFORMATION 
    fi  eld on the INFORMATION screen when an error occurs in 
    the monitor. (See page 24.)
    URL INFORMATION
    Enter a URL to display when an error occurs on the monitor.
    Up to 64 alphanumeric characters or symbols can be used.
    CONDITION
    Specify the condition to display the URL.
    CONFIRMATION
    The home page of the speci fi ed URL is displayed.
    You can check whether the URL you entered is correct.
    TIPS
    •  It is also possible to specify the message text, such as the  name of a contact or a telephone number, to be displayed 
    instead of the linked URL.
     
    						
    							M E M O
    29E
     
    						
    							North America
    MESCA (Mitsubishi Electric Sales Canada Inc.)
    http://www.mitsubishielectric.ca
    Information Technologies Group, 4299 14th Avenue, Markham, Ontario L3R 0J2,
    Canada
    Sales Phone :+1-(905) 475-7728
    Fax :+1-(905) 475-7958
    E-mail :[email protected]
    Technical Phone :+1-(905) 475-7728
    Fax :+1-(905) 475-7958
    Customer Care
    E-mail :[email protected]
    MDEA (Mitsubishi Digital Electronics America, Inc.)
    (Warranty Registration)
    http://www.mitsubishi-presentations.com/
    Presentation Products Division, 9351 Jeronimo Road, Irvine, CA 92618 U.S.A
    Phone Main Line :+1-(949) 465-6000
    Technical :+1-(888) 307-0309
    Product Information  :+1-(888) 307-0312
    Technical Support
    E-mail :[email protected]
    MITSUBISHI Contact Information
    Europe
    MEU-FRA (Mitsubishi Electric Europe B.V French Branch)
    25, Boulevard des Bouvets 92 741, Nanterre CEDEX, France
    Sales Phone :+33 (0)1 55-68-55-07
    Fax :+33 (0)1 55-68-57-31
    Technical Phone :+33 (0)1 55-68-56-42
    Fax :+33 (0)1 55-68-57-31
    MEU-GER (Mitsubishi Electric Europe B.V. German Branch)
    http://www.mitsubishi-evs.de/
    Gothaer Strasse 8, 40880 Ratingen, Germany
    MEU-IR (Mitsubishi Electric Europe B.V. Irish Branch)
    http://www.mitsubishi.ie/
    Westgate Business Park, Ballymount, Dublin 24, Ireland
    Sales Phone :+353-(0)1- 4198844
    Fax :+353-(0)1-4564422
    Technical Phone :+353-(0)1-4198807
    Fax :+353-(0)1-4198895
    MEU-IT (Mitsubishi Electric Europe B.V. Italian Branch)
    Centro Direzionale Colleoni, Palazzo Persero-Ingresso 2, Via Paracelso 12, 20041
    Agrate Brianza, Italy
    Sales Phone :+39-(0)39-60531
    Fax :+39-(0)39-6053214
    E-mail :[email protected]
    MEU-NL (MitsubishiElectric Europe B.V. Benelux Branch)
    http://www.MitsubishiElectric.nl
    Nijverheidsweg 23a, 3641 RP Mijdrecht, The Netherlands
    Sales Phone :+31-297-282461
    Fax :+31-297-283936
    E-mail :[email protected]
    Technical Phone :+31-297-282461
    Fax :+31-297-283936
    E-mail :[email protected]
    MEU (MITSUBISHI ELECTRIC EUROPE B.V.)
    http://www.mitsubishi-projector.ru/
    Moscow Representative Office, 12/1 Goncharnaya St. 109240, Moscow, Russia
    Sales Phone :+7 (095) 915 8602
    Fax :+7 (095) 915 8603
    MEU-SP (Mitsubishi Electric Europe B.V. Spanish Branch)
    http://www.mitsubishielectric.es/
    Ctra. de Rubi, 76-80, 08190 Sant Cugat del Valles, Barcelona, Spain
    Sales Phone :+34-93.565.31.54
    Fax :+34-93.589.43.88
    E-mail :[email protected]
    Technical Phone :+34-93.586.27.51
    Fax :+34-93.699.74.45
    E-mail :[email protected]
    MEU-SWE (Mitsubishi Electric Europe B.V Scandinavian Branch)
    Hammarbacken 14, Box 750, S-19127, Sollentuna, Sweden
    Sales Phone :+46-(0)8-6251070
    Fax :+46-(0)8-6251036
    Technical Phone :+46-(0)8-6251052
    Fax :+46-(0)8-6251036
    MEU-UK (Mitsubishi Electric Europe)
    http://www.mitsubishi.co.uk/evs/
    Visual Information Systems Division, Travellers Lane, Hatfield, Hertfordshire, AL10 8XB
    Sale
    s Phone :+44 (1707) 278684
    Fax :+44 (1707) 278541
    E-mail :[email protected]
    Technical Phone :+44 (870) 606 5008
    Fax :+44 (1506) 431927
    E-mail :[email protected]
    Russia (Mitsubishi Electric Europe B.V Moscow Representative Office)
    52, bldg.5, Kosmodamianskaya Nab, 113054, Moscow, Russian Federation
    Sales Phone :+7 (095) 721 2070
    Fax :+7 (095) 721 2071
    Technical Phone :+7 (095) 721 2070
    Fax :+7 (095) 721 2071
     
    						
    All Mitsubishi manuals Comments (0)

    Related Manuals for Mitsubishi Ldt521v Operation Guide