Page 1

INSTALLATION & MAINTENANCE GUIDE 

Page 2

2
NOTICE
The information contained in this document is believed to be accurate in all respects but is not
warranted by Mitel Networks Corporation (MITEL®). The information is subject to change without
notice and should not be construed in any way as a commitment by Mitel or any of its affiliates or
subsidiaries. Mitel and its affiliates and subsidiaries assume no responsibility for any errors or
omissions in this document. Revisions of this document or new editions of it may be issued to
incorporate such...

Page 3

3
Table of Contents
ABOUT THE SX-2000 APSU® ................................................................................. 4
SX-2000 Light CTI Connectivity........................................................................................... 4
INSTALLING THE SX-2000 APSU ........................................................................... 5
Required Components ......................................................................................................... 5
Installation...

Page 4

4
About The SX-2000 ApSU®
The Mitel NetworksTM SX-2000 Application Services Unit (ApSU) is a fiber connected MiTAITM
server for the SX-2000 that replaces the Application Fiber Card (AFC). It is a low cost and
maintenance-free unit that supports:
• MiTAI remote clients Version 10 or later,
• Mitel Client/Server TSP 3.0 or later.
SX-2000 Light CTI Connectivity
Currently, the MiTAI server for the SX-2000 resides on a PC and communicates with the SX-2000
PBX via fiber optic cable using the AFC (Application...

Page 5

5
Installing The SX-2000 ApSU
Required Components
To install the SX-2000 Applications Services Unit (SX-2000 ApSU), you require:
• SX-2000 ApSU
• RJ45 Ethernet cable for connecting to the LAN
• fiber-optic cable that is connected to the SX-2000 PBX
• personal computer (PC) with a connection to the same LAN as the SX-2000 ApSU, an
FTP client and Hyperterminal or a similar program for communicating over a serial port
• serial cable to connect the SX-2000 ApSU to the PC’s COM port.
Note:Some Windows...

Page 6

6
Note:If the SX-2000 ApSU is left in this mode (displaying the prompt and waiting for input), it
will eventually restart automatically.
10. Enter p at the prompt to display the current boot parameters of the SX-2000 ApSU.
Note:Some fields will not be displayed if they have no value. The c command will allow you to
set or change the values for all the fields.
The output from the p command should resemble the following (values will be different and
additional fields may be displayed):
[MC269AA Boot]-: p...

Page 7

7
Boot ParameterNotes/Comments
host inet (h)Do not change this value. It is not used
when the boot device is flash.
gateway inet (g)The IP address of the gateway for the LAN
to which the SX-2000 ApSU is connected.
user (u)Do not change this value. It is not used
when boot device is flash.
FTP password (pw) (blank = use rsh)Do not change this value. Is not used
when boot device is flash.
flags (f)Leave value as 0x0.
target name (tn)Can leave blank.
startup script (s)Leave blank.
other (o)Must have the...

Page 8

8 4. 
In the Settings screen, select whether you wish to use Default settings or settings from a pre-
existing MiTAI.dat file. After making your selection, click Next.
5. The Path screen will display the name of the directory in which the MiTAI Client will be
installed. You may modify this if you wish the software to be installed into a different location
on your PC. Click Next when finished.
6. The Folder screen will prompt you to select where you would like the MiTAI Client software to
appear on your...

Page 9

9
system is with an FTP client to connect to the SX-2000 ApSU. This can be done while the
SX-2000 ApSU is running without interfering with its operation.
Here is sample output from an FTP client session:
ftp 10.10.10.2
Connected to 10.10.10.2.
220 VxWorks FTP server (VxWorks 5.4) ready.
User (10.10.10.2:(none)):
331 Password required
Password:
230 User logged in
ftp> dir
200 Port set okay
150 Opening BINARY mode data connection
-rwx---A--  1 user    group           81 Jan  1  1980 DATETAG.TXT
-rwx---A--...

Page 10

10
The following is an example of the upgrade files stored in an Install directory:
    Friday, December 20, 2002 11:52 AM       469271 apsucore.o
  Thursday, December 19, 2002 10:46 AM          499 apsumain.cmd
    Friday, December 20, 2002 11:51 AM           81 Datetag.txt
    Friday, December 20, 2002 11:57 AM      1974152 hcivxwk.out
    Friday, December 20, 2002 11:58 AM       731289 mitaivxw.out
  Thursday, December 19, 2002 10:45 AM        22344 pri_fpga.bin
    Friday, December 20, 2002 11:53 AM...