Page 11
Engineering Information SX-200 PABX DTMF SETS ROTARY SETS PAGING/MUSIC ON HOLD 7876RZE4 Figwre 2-3 SX-ZOO@ DIGITAL PABX Peripherals Page Z-4/4
Page 12
Engineering Information 3. PHYSICAL DESCRIPTION General 3.01 Each equipment cabinet (refer to Figures 3-1 through 3-4), is of metal construction and has the following dimensions: height 965 mm (38 in.), width 600 mm (23.5 in.) and depth 700 mm (27.5 in.). A fully equipped system weighs approximately 400 kg (900 lb). 3.02 All connections from the cross-connecting terminals to the equipment cabinets are made using connectorized cables. Con- nections between the cross-connecting terminals and...
Page 13
Engineering Information Peripheral Equipment Cabinet 3.06 The door on the front of the SX-2008 peripheral equipment cabinet (Figure 3-4) provides access to- the peripheral main- tenance panel, and two analog equipment bays. The rear doors provide access to the backplanes, equipment interface connectors and the rear door power supply. Connection to the control equipment cabinet is made through the cable ducts located at the bottom of either of the cabinet side panels. Maintenance Panels 3.07 The...
Page 14
Engineering Information BAY 3 III BAY 1 BAY 2 PE~IPP~FRAL / ‘I 7-A MAINTENANCE PANEL c PERIPHERAL SHELF CONTROL SHELF FAN ASSEMBLY I :I KAOl90RlEl Figure 3-l Control Cabinet Page 3-3
Page 15
Engineering Information BAY 3 POWER SWITCH PERIPHERAL SHELF (SAV 3) / MAINTENANCE PANEL PERIPHERAL SHELF BAY 4 BAV 2 I I CONTROL SHELF / CONTROL SHELF . POWER’SUPPLV- KAOllZRlEl Figure 3-2 Universal Cabinet with Peripheral Bay Page 3-4
Page 16
Engineering Information PERIPHERAL SHELF 1 BAY 4 BAY 3 l-----III l------l&& BAY 1 I CONTROL SHELF MAINTENANCE PANEL FANS POWER DISTRIBUTION AC FILTER ” KA0133RZE Figure 3-3 Universal Cabinet with Digital Peripheral Bays Page 3-5
Page 17
Engineering Information MAINTENANCE CABLE - :‘:‘L 1 II BAY 3 BAY 4 --- CABLE /------ CLAMP POWER SUPPLY KA0199RlEl Figure 3-4 Peripheral Cabinet Page 3-6
Page 18
Engineering Information Power Supplies 3.09 The power supplies for the digital bays are card-mounted and slide into the card shelf from the front. The power supplies for the analog peripheral bays (one for Bay 3, and one for Bays 4 and 5) mount directly on the cabinet back door (weight: 31.8 kg (70 lb)). Printed Circuit Cards 3.10 All circuit cards (see Figures 3-5 and 3-6) within the PABX consist of a fibreglass board with printed wiring patterns on both sides. Riveted to the front of each...
Page 19
Engineering Information I ‘NIVERSAL CARD MODULE INDICA- TORS I ALARM -LED L I’ 1 INE NDIGA- ‘ORS ALAR LED Ir e ONS ALARM -LED LINE CARD 4 l LSIGS TRUNK CARD TRUNKO - 6 1 TRUNK INDICATORS iiP LINE INDICA- TORS ALARh TED TRUNK INDICA- TORS RM TRUNK INDICA- TORS ALARM -LED COV LINE OPS CARD TRUNK CARD DID TRUNK CARD KA0207RlE Figure 3-5 SX-200m Peripheral Cards Page 8-8
Page 20
Engineering Information SUPERSET LINE CARD LINE INDICATORS DIP SWITCHES r TRUNK INDICATORS 1 ALARM’ LED C.O. TRUNK CARD KAO208ROEU Figure 3-6 SX-200@ Peripheral Cards Page 3-9