Page 31
Pull the condenser unit out of its housing by the handle. Checking the condenser unit Hold the condenser unit up to the lightas shown. Check to see if there is any fluff inside it. The arrows in the illustration above indicate where to look.If you cannot see any fluff: Replace the condenser unit (see following page). If you can see some fluff: Clean the condenser unit as described below. Cleaning the condenser unit When rinsing the condenser unit, make sure you position it as shown in the next...
Page 32
Then flush the unit through from the front. Check the condenser unit again for any visible fluff and if necessary flush it through again until it has all gone. Remove any soiling still visible inside the housing unit. Also make sure the rubber seals are clean. The rubber seals must not be removed and must be free of kinks. Shake any excess water out of the unit until no more water droplets are visible.Replacing the condenser unit With the handle facing upwards, push the condenser unit back into...
Page 33
Problem solving guide Most faults can be resolved by yourself. This will save time and money as a call-out charge will apply to customer service visits where the problem could have been rectified as described in these Operating instructions. With the help of the following notes, minor faults in the performance of the appliance, some of which may result from incorrect operation, can be put right without a call-out being necessary. Please note: Repair work to electrical appliances must only be carried out...
Page 34
Problem Possible cause Remedy The following flashes at the end of a programme: —œ–...C~–...Cœ˜...The programme has finished but the laundry is still cooling down.You can remove the laundry and spread it out to allow the heat to dissipate, or leave it in the dryer to cool down more. TheClean out airways indicator light comes on.The dryer is not working efficiently or economically. Possible cause: Blockages due to fluff or detergent residues.–Cleaning the filters is usually all that is required. However,...
Page 35
Problem Possible cause Remedy The indicator light Start/Stopflashes slowly and the display is dark.The dryer is on standby. This is a normal function and does not indicate a fault.See Programmable functions. Some programmes wont start anymore. The indicator light for that programme doesnt light up anymore either.There is no immediate cause.–Switch the dryer off and then on again. –Select the programme that cannot be started. –If you still cant start the programme, there is a fault. Contact Miele....
Page 36
An unsatisfactory drying result Problem Possible cause Remedy The laundry is not sufficiently dry.The load consisted of different fabrics.–Final drying cycle with Warm air. –Select a different programme next time*. Items made of synthetic fibres are charged with static electricity after drying.Synthetic fibres tend to attract a static charge.Static charges can be reduced by adding a fabric conditioner to the final rinse in the washing programme or a fabric conditioner sheet to the load when drying. There...
Page 37
Other problems Problem Possible cause Remedy The drying process goes on too long or even switches off.In some circumstances, the Clean out airways indicator light still comes on, even though the filters are clean. Clean out airways.Please check all the possible causes and switch the dryer off and then back on again. Ventilation to and from the dryer may be insufficient (e.g. because it is installed in a small room). This has caused the temperature in the room to rise sharply.Open a door or window while...
Page 38
Problem Possible cause Remedy Water leaks from the machine after the condenser unit has been cleaned.–The inner cover of the condenser unit has not been locked properly and/or the condenser unit has not been positioned correctly. –There is a build-up of fluff.–Ensure that the condenser unit is positioned correctly and lock the inner cover. –Check the rubber seals. –Use a cloth to remove any visible fluff from the inside of the condenser unit housing. A programme cannot be started.There is no immediate...
Page 39
Changing the lamp Disconnect the machine from the mains electricity supply. Open the door. You will find the interior lamp cover at the top of the drum aperture. Insert a suitable tool, such as a wide bladed screwdriver, under the side edge of the lamp cover as illustrated. Apply a little pressure and, whilst doing so, turn your wrist in the direction of the arrow to open the cover. The cover will open downwards. The temperature resistant lamp should only be ordered from your Miele Chartered Agent or...
Page 40
In the event of any faults which you cannot remedy yourself, please contact –Your Miele Chartered Agent or –Miele (see back cover for address). When contacting Miele, please quote the model and serial numbers, both of which are located on the data plate situated on the right-hand side below the drum aperture.Future updates (PC) The indicator or check light markedPC on the control panel is the interface used by the Miele service technicians during service work for testing purposes and for updating the...