Have the appliance installed by a qualified technician, according to the enclosed installation instructions. WARNING This appliance is top-heavy and must be secured to prevent it from tipping forward. Keep the doors closed until the appliance is completely installed and secured as per the installation instructions. Empty weight of your machine: KF 18X1 Vi.........455lbs(206 kg) KF 19X1 Vi.........496lbs(225 kg) Installation site The appliance should be installed in a dry, well-ventilated room. Do not install the appliance: - outdoors - in an environment with dripping water - in rooms that are at risk of frost. The installation location should not be exposed to direct sunlight, nor near a heat source, such as an oven, radiator, etc. The ambient temperature should not drop below 55°F (13°C) or rise above 110°F (43°C), otherwise malfunctions may occur. If installation next to a heat source is unavoidable observe the following minimum distances from the heat source: –1 1/4 (3 cm) from an electric cooktop or electric oven. – 12 (30 cm) from a gas or oil cooktop, range or oven. Installation 51
Base A fully loaded appliance is very heavy. The load-bearing capacity of your floor must meet the following requirements: KF 18X1 Vi.........950lbs(431 kg) KF 19X1 Vi.......1,185 lbs (537 kg) To ensure that the appliance is installed securely and functions properly, the base must be flat, level and made of a hard, rigid material. If in doubt, contact Miele. Furniture/fixtures The new appliance will be mounted securely to adjacent and overhead furniture/fixtures. For this reason, it is essential that all attachable furniture/fixtures be connected securely to the floor or wall by a suitable means. Ventilation The air intake and outlet must not be blocked or covered in any way. They also need to be dusted/cleaned on a regular basis. Installation niche To ensure safe, trouble-free installation and the best possible cosmetic result, check to be sure that the installation space complies with the installation dimensions. See Niche dimensions. The side walls of the installation cavity must be plumb. The minimum thickness of the side walls and the top wall must be 5/8 (16 mm). The minimum thickness of the toe-kick panel must be ½ (13 mm). A thickness of 3/4 (19 mm) is recommended. Installation 52
Stainless steel panels Stainless steel door panels and toe-kick covers are available from Miele. Custom door panels This appliance is compatible with all styles and designs of kitchen cabinetry. The total weight of the decorative panel(s) must not exceed the following: KF 18X1 Vi Upper door..........104lbs(47kg) Lower door...........22lbs(10kg) KF 19X1 Vi Upper door...........84lbs(38kg) Lower door...........31lbs(14kg) Installation options There are many different installation options. You are limited only by the design of the kitchen. The door hinge cannot be exchanged. Single column The appliance can be installed at any preferred location in the kitchen. However, be sure the door will open and close properly in the chosen location.Side-by-side This appliance can be installed side-by-side with another fridge/freezer using a Merging Kit. The Merging Kit is available from Miele. Contact Miele or your dealer for specific information about which combinations will work with your appliance. For instructions on how to attach the appliances and install the heating mat, please refer to the instructions included with the Merging Kit, available from Miele. Appliances attached together using the Merging Kit If the appliances are installed directly next to each other (without a partition), they need to be attached together using the Merging Kit. Installation 53
Installation with partition using the Merging Kit The minimum thickness of the partition is 5/8 (16 mm). If there is a partition with a thickness from 5/8 (16 mm) to 65/16 (160 mm) between the adjacent appliances, then each appliance should be individually installed within its own niche using the mounting accessories included. The Merging Kit will also be needed. The Merging Kit is available from Miele. Installation with partition without using the Merging Kit If there is a partition with a thickness of more than 6 5/16 (160 mm)between the adjacent appliances, then each appliance should be individually installed within its own niche using the mounting accessories included (the Merging Kit is not necessary). Side panels If one side of the appliance is visible, a side panel must be used. The side panel must be firmly secured to the wall, the floor and the overhead furniture/fixtures before the appliance is placed in the cavity. The dimensions of the side panel are taken from the opposite wall of the installation space. During installation, ensure that the cavity is square and the measurements are correct. Installation 54
Adjusting the door opening angle (optional accessory) Depending on the installation site, it may be necessary to adjust the door opening angle to 90°. Open the door. Insert the banking pin through the holes and drive in with a hammer. The door opening angle is now limited to 90°. Front panel gap kit (optional accessory) Two adjacent furniture doors can be attached instead of one large door. To connect these furniture doors, a metal strip can be purchased as an optional accessory. Contact Miele. When attaching the metal strip to the furniture doors, observe the maximum length of the screws and the position of the drill holes. Always screw into the best possible load-bearing material of the custom doors. Installation 55
Door dimensions (opening angle 90°) *The dimensions of the door fronts and handles will vary according to each individual kitchen. 3/8 (10 mm) ABC KF 18X1 Vi32 5/8 (829 mm) Door front max. 11/2 (38 mm)* Door handle* KF 19X1 Vi38 11/16 (982 mm) Door front max. 11/2 (38 mm)* Door handle* Door dimensions (opening angle 115°) *The dimensions of the door fronts and handles will vary according to each individual kitchen. ABCD KF 18X1 Vi32 5/8 (829 mm) Door front max. 11/2 (38 mm)Door handle*14 5/16 (363 mm) KF 19X1 Vi38 11/16 (982 mm) Door front max. 11/2 (38 mm)Door handle*16 7/8 (428 mm) Dimensions 56
Niche dimensions Niche width (A) KF 1801 Vi, KF 1811 Vi30 (762 mm) KF 1901 Vi, KF 1911 Vi36 (915 mm) Dimensions 57
Power supply and water connection 1. Power supply 2. Water connection A KF 18X1 Vi15 (381 mm) KF 19X1 Vi18 (458 mm) Door front dimensions ABC KF 18X1 Vi53 5/16 1354 mm2913/16 758 mm26 7/16 672 mm KF 19X1 Vi53 5/16 1354 mm353/4 908 mm267/16 672 mm 4 - 5 3/16 (102 - 132 mm) 1/8 - 3/16 (3-5mm) Dimensions 58
Before you begin Read these instructions completely and carefully. Have the appliance installed by a qualified technician, according to the enclosed installation instructions. To reduce the risk of injury or damage to the product, two people should be used for installation. These installation instructions are intended for use by qualified installers. In addition to these instructions, the appliance must be installed in accordance with all local codes. In the absence of a local code, the following should be used: – In the USA, the National Electric Code, ANSI/NFPA 70 - latest edition/State and Municipal codes and/or local codes. – In Canada, the Canadian Electric code C22.1 - latest edition/Provincial and Municipal codes and/or local codes. Tools needed for installation – Cordless screwdriver – Torx screwdriver – Hammer drill – Wood drills in different sizes – Hammer – Rachet ( 5/16/8mm)–Adhesive tape –Multi-grip pliers –Level –Tape measure –Square When fastening the cabinet to the wall behind it (see Installing the appliance) use: –suitable plugs/screws depending on the type of wall. –several mounting brackets, if required. Other – Stepladder – Dolly, hand truck – Wooden beam (cross section min. 3 x 4 [75 mm x 100 mm] as an alternative tilt protection, length depends on the width of the installation cavity) – Wood screws in different sizes Optional accessories – Merging Kit for side-by-side installation – Front panel gap kit – RemoteVision module for wireless monitoring Installing the appliance 59
Aligning the housing unit The housing unit must be carefully aligned using a spirit level before installing the appliance. The unit corners must be at right angles, as otherwise the furniture door will not align correctly with the 4 corners of the appliance. – The side panels of the housing must be even. – The housing unit panels must be at least 16 mm thick. – The plinth facing must be at least 13 mm thick (or preferably 19 mm). Check the installation niche To ensure a safe, trouble-free installation and the best possible cosmetic result, check to be sure that the installation space complies with the installation requirements. Check the base (see Installation). Check the dimensions of the cavity. Check that the cavity is square. Check the location of the power outlet. Check the location of the water connection (see Plumbing). Check that all furniture parts in the vicinity of the appliance are securely connected to the wall. Check that the adjacent furniture/fixtures do not collide with the open door. Before installation Caution - the appliance is very heavy. Use caution when unpacking and opening the door, danger of tipping. To protect the base from damage during installation, attach a hard board, linoleum, etc., to the floor in front of the intended installation location. Take the supplied accessories out of the protective packaging. Installing the appliance 60