The Miele waterproof anti-leak system Providing your dishwasher has been installed correctly, the Miele waterproof anti-leak system will protect you from water damage throughout its lifetime. Connection to the water supply ,Water in the dishwasher must not be used as drinking water. –The dishwasher may be connected to a cold or hot water supply, max. 60 °C. We would only recommend connection to a hot water supply if it is economical, e.g. a solar powered supply. When connected to a hot water supply all programme stages which would otherwise be carried out with cold water will be carried out with hot water. ,A warm water connection with temperatures exceeding 60 °C may cause damage to the unit and affect the product guarantee. – The inlet hose is approx. 1.5 m long. A 1.5 metre long flexible metal extension hose, pressure tested to 14,000 kPa/ 140 bar, is available as an optional accessory if required. – A stopcock with a 3/4 male thread must be provided on site.–The dishwasher is constructed to comply with Australian regulations, and may be connected to a suitable supply without an extra non-return valve if national regulations allow this. –The water pressure (flow pressure at the take-off point) must be between 30 and 1000 kPa (0.3 and 10 bar). If the water pressure is too high, a pressure reducer valve must be fitted. ,To avoid any damage to the appliance, the dishwasher must only be connected to a fully vented plumbing system. Plumbing 61
!The inlet hose mustnotbe shortened or damaged in any way as it contains electrical components (see illustration). This appliance incorporates back - flow protection complying with AS/NZS 3500.1.2. No further backflow protection required for connection to the water supply. Plumbing 62
Drainage –The appliance drainage system is fitted with a non-return valve, which prevents dirty water from flowing back into the dishwasher via the drain hose. –The dishwasher is supplied with approx. 1.5 m of flexible drain hose with an internal diameter of 22 mm. –The drain hose can be extended using a connection piece to attach a further length of hose. The drainage length must not be longer than 4 m, and the delivery head must not exceed 1 m. – If the hose is to be directly fitted to the drainage outlet on site, use the hose clip supplied (see installation diagram). – The hose can be directed to the left or the right of the appliance. – The on-site connector for the drain hose can be adapted to different widths of hose. If the connector protrudes too far into the drain hose, it will need to be shortened. Otherwise the drain hose may become blocked. – The drain hose must not be shortened. ,Make sure that there are no kinks in the hose, and that it is not squashed or stretched.Venting the drainage system If the on-site drain connection is situated lower than the guide path for the bottom basket rollers in the open door, the drainage system must be vented. Otherwise a siphoning effect during a programme can cause the appliance to empty itself of water. To vent it: ^Open the dishwasher door fully. ^ Pull the lower spray arm firmly upwards to remove it. ^ Cut off the top of the vent valve in the wash cabinet. Plumbing 63
Dishwasher model G 1XXX G 2XXX Height 80.5 cm (adjustable + 6.5 cm)84.5 cm (adjustable + 6.5 cm) Height of building-in recessMin. 80.5 cm (+ 6.5 cm) Min. 84.5 cm (+ 6.5 cm) Width 59.8 cm 59.8 cm Width of building-in recess60 cm 60 cm Depth 57 cm 57 cm Weight Max. 55 kg Max. 61 kg Voltage 230 V 230 V Connected load 2300 W 2300 W Fuse rating 10 A 10 A Test marks Electrical safety, Typetest Mark, C-Tick MarkElectrical safety, Typetest Mark, C-Tick Mark Electrically suppressed according toAS/NZS 1044 AS/NZS 1044 Water pressure (flow rate) 30 - 1000 kPa (0.3 - 10 bar)30 - 1000 kPa (0.3 - 10 bar) Hot water connection Up to max. 60 °C Up to max. 60 °C Delivery head Max. 1 m Max. 1 m Drainage length Max. 4 m Max. 4 m Mains cable Approx. 1.7 m Approx. 1.7 m Capacity 12 place settings 14/12 place settings* * depending on model Technical data 64