Home > Miele > Ventilation > Miele Da2894 Manual

Miele Da2894 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Miele Da2894 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 171 Miele manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Installation Instructions 
    						
    							Disposal of packing material
    The cardboard box and packing
    materials protect the appliance during
    shipping. They have been designed to
    be biodegradable and recyclable.
    Please recycle.
    To prevent suffocation of children,
    ensure that any plastic wrappings,
    bags, etc. are disposed of safely
    and kept out of their reach.
    Disposal of an old appliance
    Old appliances may contain materials
    that can be recycled. Please contact
    your local recycling center about the
    possibility of recycling these materials.
    Before discarding an old hood,
    unplug it from the outlet and cut off
    its power cord to prevent hazards.
    Caring for the environment
    23 
    						
    							a3 protective shields
    prevent scratches to the chimney
    during installation.
    bUpper retaining platesecures the
    chimney extension.
    cMiddle retaining platefor
    additional stability of the chimney.
    d2 hose clipsfor securing the
    ducting.
    e1 reducing collar
    for use with 5 (125 mm) exhaust
    ducting.
    Caution: During the installation
    process, please be careful of sharp
    edges that can cause harm.5 large headed screws 5 x 40 mm
    for securing the retaining plates and the
    canopy.
    (S8 wall anchors included in the
    packaging are not for use in USA /
    CDN.)
    2 screws 5 x 60 mmfor securing the
    chimney.
    6 screws 3.5 x 9.5 mmfor securing the
    canopy and filter housing
    2 screw covers
    1 leverfor dismantling the chimney and
    changing the light bulbs
    Installation instruction sheet
    Installation accessories
    25 
    						
    							The majority of the weight of the
    installed ventilation system will be
    supported by the lower retaining
    plate. It must be firmly attached to
    the stud framingbehindthe drywall.
    If studs are not available in the
    required locations, a plywood
    backing (min.
    ½ (13 mm) thick)
    spanning at least two studs mustbe
    installed. Failure to adequately
    support the weight as stated may
    result in the ventilation system falling
    off the wall, causing personal injury
    and property damage.
    (If plywood backing is not needed, proceed to the included installationsheet.)
    To install a plywood backing
    ^ Determine and mark the location of
    the retaining plate for the canopy as
    outlined on the installation sheet.
    ^ Make a cutting line 3 (76 mm) above
    and 3 (76 mm) below the outline of
    the retaining plate. ^
    Find the studs to the left and right of
    the mounting location by tapping the
    wall or using a stud finder.
    ^ Mark a vertical cutting line along the
    center of each stud.
    Be careful not to damage any wiring
    or plumbing that may be located
    behind the wall. Make sure that the
    power supply to the area where this
    installation is being performed has
    been turned off at the breaker panel
    before cutting into the wall.
    ^ Remove the drywall between the
    cutting lines and replace it with
    plywood of a matching thickness
    (min.
    1/2 (13 mm) thick). Tape the
    joints and refinish the wall.
    ^ Proceed to the included installation
    sheet to complete the installation.
    Plywood backing
    26 
    						
    							All electrical work should be
    performed by a qualified electrician
    in strict accordance with national
    and local safety regulations.
    Installation, repairs and other work
    by unqualified persons could be
    dangerous. The manufacturer
    cannot be held responsible for
    unauthorized work.
    Ensure that power to the appliance
    is OFF while installation or repair
    work is performed.
    ^Verify that the voltage, load and
    circuit rating information found on the
    data plate (located behind the
    grease filters), match the household
    electrical supply before installing the
    hood.
    ^Use only with rangehood
    cord-connection kits that have been
    investigated and found acceptable
    for use with this model rangehood.
    If there is any question concerning the
    electrical connection of this appliance
    to your power supply, please consult a
    licensed electrician or call Miele’s
    Technical Service Department.
    U1-800-999-1360
    V1-800-565-6435
    WARNING:
    THIS APPLIANCE MUST BE
    GROUNDEDGrounding Instructions
    This appliance must be grounded. In
    the event of an electrical short circuit,
    grounding reduces the risk of electric
    shock by providing a path of least
    resistance. This appliance is equipped
    with a cord having a grounding wire
    with a grounding plug. The plug must
    be plugged into an outlet that is
    properly installed and grounded.
    WARNING - Improper grounding can
    result in a risk of electric shock.
    If there is any doubt, have the electrical
    system of the house checked by a
    qualified electrician. The manufacturer
    cannot be held responsible for
    damages caused by the lack, or
    inadequacy, of an effective grounding
    system.
    Do not use an extension cord. If the
    power supply cord is too short, have a
    qualified electrician install an outlet
    near the appliance.
    Important
    The hood comes equipped with a 4 ft
    (1.2 m) power cord with a NEMA 1-15
    molded plug for connection to a
    120 VAC, 60 Hz, 15 A power outlet.
    Maximum load . . . . . . . . . . . . . . 390 W
    Light . . . . . . . . . . . . . . . . . . . . . 4 x 10 W
    Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
    Frequency . . . . . . . . . . . . . . . . . . 60 Hz
    Circuit rating . . . . . . . . . . . . . . . . . . 15 A
    Electrical data
    27 
    						
    							1) and 2)
    Cut out area in wall or ceiling for
    entrance of 6 (150 mm)
    ductwork or 5 (125 mm) ductwork with
    a reducing collar.
    Do not install this exhaust hood over
    cooktops burning solid fuel.
    Provided a larger distance is not
    given by the manufacturer of the
    cooktop, follow the recommended
    minimum safety distances between
    a cooktop and the bottom of the
    grease filter of 30 (762 mm).
    If local building codes require a
    greater safety distance, follow their
    requirement.
    Follow the safety distances
    recommended by the cooktop
    manufacturer in their installation and
    operating instructions.
    If there is more than one appliance
    beneath the hood and they have
    different minimum safety distances
    always select the greater distance.
    See IMPORTANT SAFETY
    INSTRUCTIONS for further
    information.Distance between cooktop and
    hood (S)
    ^To observe the safety distance and
    ensure an optimum function and use
    of the hood, a distance ofS = 14
    3/8"
    (365 mm)between the cooktop and
    the lower edge of the glass pane is
    recommended.
    ^If the hood is fitted flush to the
    ceiling, the sum of
    S + H + Workspace
    should not exceed the room height.
    Standard unit height H
    37 7/8 - 51 7/8
    (960 - 1320 mm)
    To fit the lower chimney section, the
    distance between the top of the
    chimney and the ceiling must be at
    least
    7/8 (20 mm).
    Appliance dimensions
    29 
    						
    							Installation instructions
    ^See the enclosed installation
    instruction sheet.
    ^Please read the Important Safety
    Instructions and Installation
    instructions before installing this
    hood.
    Protective film
    The casing is covered with a protective
    film to prevent scratching during
    transport.
    ^Peel off the film before installing the
    casing parts.
    Dismantling
    If the hood needs to be disassembled,
    follow the instructions on the installation
    sheet in the reverse order.
    A lever is enclosed for easier removal
    of the chimney extension.
    ^After removing the screws from the
    chimney, slide the lever between the
    chimney and the chimney extension
    and gently apply pressure to ease
    the chimney from its hooks.
    Installation
    30 
    						
    All Miele manuals Comments (0)