Midway Artic Thunder Game Operations Manual For 27 Dedicated Video Game
Here you can view all the pages of manual Midway Artic Thunder Game Operations Manual For 27 Dedicated Video Game. The Midway manuals for Games are available online for free. You can easily download all the documents as PDF.
Page 81
CHAPTER 4 PARTS ARCTIC THUNDER21 Bulbs, Filters and FusesPart Number Bulb #555 6.3V, 0.25A 24-8768 Bulb #1093 12v 24-8882 Bulb #161 24-8840 Fuse, sb 5A 250v 5731-09651-00 Fuse sb 4A 5X20mm 5731-14094-00 Fuse .63A 250V sb 5X20mm 5731-15627-00 Fuse 5X20mm 2A slow blow 5735-13853-00 Fuse sb t5a 5X20mm 5731-14046-00 Fuse 5X20, s/b10a 250v 5731-14229-00 Fuse sb 3A 250v 5731-10356-00 Fuse block 2X3ag 1/4 term 5733-15139-00 Ferrite Bead, 1 1/4 SQ 5556-13956-00 CablesPart Number Linking Cable, 10 Base-T 16FT...
Page 82
CHAPTER 4 PARTS 22 MIDWAY AMUSEMENT GAMES, LLC LINE CORD APPLICATION CHART COIN DOOR APPLICATION CHART Part No. Country5850-14699-005850-14699-015850-14699-025850-14699-03585014699-06 USA • UK Italy Japan New Zealand Germany Spain Denmark Finland Holland Norway Switzerland Hungary Canada Austria France Australia Belgium Sweden Part No. Country09-96026-1409-96026-2009-96026-3309-96027 USA UK Italy Japan New Zealand Germany Spain Denmark Finland Holland Norway Switzerland Hungary Canada...
Page 83
CHAPTER 4 PARTS ARCTIC THUNDER23 TRANSFORMER APPLICATION CHART /2: 92/7$*( &211(&725 75$16)250(5 /,1( 92/7$*( &211(&725 Part number Voltage & Country5610-16292-005610-16293-005610-16294-005610-16520-005610-16521-00 230 VAC Australia 230 VAC Austria 230 VAC Belgium 230 VAC Canada 230 VAC Denmark 230 VAC Finland 230 VAC France 230 VAC Germany 230 VAC Holland 230 VAC Hungary 230 VAC Italy 100 VAC Japan 110 VAC Japan 230 VAC New Zealand 230 VAC Norway 230 VAC Spain 230 VAC Switzerland 230 VAC...
Page 88
4MIDWAY AMUSEMENT GAMES, LLC CHAPTER 5 WIRING SUBSTITUTE BOARD S1 DIP SWITCH SETTING TABLE Default position is shown in boldface type. S2 DIP SWITCH TABLE Default position is shown in boldface type. Function Sw1 Sw2 Sw3 Sw4 Sw5 Sw6 Sw7 Sw8 Not Used Not UsedOn Off Not Used Not UsedOn Off Not Used Not UsedOn Off Not Used Not UsedOn Off Arctic Not Valid PositionOn Off Not Used Not UsedOn Off Not Used RS-232On Off Disable Watchdog Enable WatchdogOn Off Function Sw1 Sw2 Sw3 Sw4 Sw5 Sw6 Sw7 Sw8 Boot Diag Boot...
Page 89
ARCTIC THUNDER5 CHAPTER 5 WIRING SUBSTITUTE BOARD LED INDICATOR STATUS TABLE Designation Location Function Color State Meaning D 28 Near fuse F2 & JP15 connectorIndicator Red OFF ON BLINKINGNo +5V +5V Present Intermittent +12V D 25 Near fuse F1 Indicator Red OFF ON BLINKINGNo +12V +12V Present Intermittent +12V D 24 Near U5 Indicator Red OFF ON BLINKINGNot in use Communication error Normal operation D 23 Near U5 Indicator Red OFF ON BLINKINGNot in use EEPROM Not Responding Normal operation D 22 Near U5...
Page 90
ARCTIC THUNDER6 CHAPTER 5 WIRING AUDIO AMPLIFIER LED INDICATOR TABLE Notes: 1. Active output protection circuit. To reset circuit, clear fault and switch off power. 2. Blinking caused by either intermittent audio overload or overheating. LED is only supposed to blink during start-up. WHEEL DRIVER LED INDICATOR TABLE Notes: 1. The regulated power supply voltage source is monitored by LED 1, which should remain lit non-stop. Blinking or failure to illuminate indicates an intermittent connection, power...