    Congratulations on your purchase of the Lyman 1000 XP Precision
    Electronic scale. This is a precision piece of equipment and should
    be handled with care. Before using the 1000 XP, please read these
    instructions fully and become familiar with its operation and 
    features. If you do not understand some of the operations or have
    questions above the use of the scale, call us at 1-800-22-LYMAN
    (Foreign customers may call 860-632-2020).
    Set-Up
    1. Select a location for the 1000 XP that is level and stable. It is 
    recommended that the scale be located away from a loading
    bench equipped with a reloading press. Most benches are not
    heavy enough to prevent vibrations being transferred to the
    scale. The scale should also be positioned away from any source
    of drafts, air currents, or temperature changes. The 1000 XP is
    sensitive enough to be affected by these conditions.
    2. The 1000 XP runs on a 9-volt battery, or an AC power adapter.
    The battery is installed in the compartment on the underside of
    the scale. There is an outlet for the optional power adapter on
    the rear left-hand side of the scale.
    3. The scale is equipped with a clear plastic dust cover. The cover
    can be hinged back or removed if desired. A latch at the front of
    the scale locks the dust cover down. To remove the dust cover,
    slide the button at the rear of the scale to the right. Unlatch the
    dust cover and tilt it back. Tip the cover slightly to the right and
    out of its left-hand groove first, then and lift the cover from the
    slot on the right-hand side. To reinstall the cover, reverse the
    above procedure.  It is recommended that the cover be in place
    when the scale is not in use to protect the platform and load cell.
    Project5  3/3/05  4:20 PM  Page 2 
    						
    							4. For the first use, it is recommended that the scale be allowed
    to stabilize to its surroundings for 24 hours.This is 
    particularly important if the scale has been recently transported
    or subjected to changes in temperatures.
    Calibration
    1. It is recommended that the scale be calibrated before each use,
    or if the scale is moved or jarred in any way.
    2. Turn on the scale by pressing the ON/OFF button.
    3. Press the ZERO button to reset the scale to zero.
    4. Press and hold down the CAL button until the display shows 
    “Cal 20” then release it.
    5. Place the supplied 20-gram calibration weight on the platform
    and press the CAL button again. (Press and release, do not hold
    it down.)
    6. The scale will now show 0.0 on the display. Remove the 20-gram
    weight. The display will now show approximately –308.6.
    7. Press the ZERO button one more time to reset zero. 
    Scale Use
    1. Place the empty powder pan on the platform and press the ZERO
    button to reset the scale to zero.
    2. The scale is now ready to weigh powder. 
    3. The scale can be changed to display grains or grams as desired.
    Press the MODE button to switch the scale from one to the
    other. In grain mode, the scale will display “gn”, in gram mode
    the scale will display “g”.
    4.It is recommended that the ZERO button be pressed on 
    occasion during use (approximately every 10 loads being
    weighed) to ensure that the scale is maintaining its zero or
    any time the display is off zero when a empty powder pan is
    on the platform.
    5. The scale is equipped with an auto-shutoff feature when batteries
    are in use. The scale will auto-shutoff after approximately 15 
    minutes of non-use to save battery life.
    6. The display will show “LoBat” to indicate a low power condition
    when a battery is being used.
    7. To shut-off the scale, press and hold down the ON/OFF button
    for several seconds.
    Project5  3/3/05  4:20 PM  Page 3 
    						
    							Cautions
    1. Never leave a load on the scale for a prolonged period of time as
    this can damage the load cell.
    2. Always place the calibration weight or a load gently onto the
    scale. Dropping the weight on the scale may cause permanent
    damage to the load cell.
    3. Do not attempt to disassemble the scale. There are no user serv-
    iceable parts inside the scale.
    4. Do not pull or pry on the platform. Damage to the scale can result.
    Limited Warranty
    Lyman Products Corp. warrants to the original retail purchaser 
    of this scale for a period of one year from the date of purchase that
    the scale is free from defects in materials and workmanship. A
    defective scale returned postage-paid by the purchaser to Lyman
    Products Corp. with dated sales receipt within the one year period
    will be repaired or replaced free of charge, provided that the
    returned product has not been subject to abuse, unreasonable use,
    tampering, neglect or excessive wear. Please include a description of
    the alleged defect.
    For questions please contact Lyman Customer Service toll free at 
    1-800-22-LYMAN (Foreign customers may call 1-860-632-2020).
    Lyman Products Corp.
    475 Smith St., Middletown, CT 06457
    www.lymanproducts.com
    1/05