DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Exposed Port Protection 3-3 Recommended Protectors and IROB Protection 3 Recommended Protectors and IROB Protection Table 3-1 shows the recommended protectors for the DEFINITY G1, G2, and G3, DEFINITY ECS, System 75, and System 85. Table 3-2 shows the in-range, out-of- building (IROB) protection for DEFINITY line circuits and terminals. !CAUTION: The following circuit...
Page 62
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Exposed Port Protection 3-4 Recommended Protectors and IROB Protection 3 * Key to Abbreviations: P = Primary; EP = Enhanced Primary Notes: 1. Primary protection with heat coils for sneak protection are coded with the number4as the first numeric. DEFINITY ports require sneak current protection for IROB terminal installations. 2. The TN754, V1 through V13 may be installed...
Page 63
Adjunct Power 4-1 4 DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 4 Adjunct Power Power for several of the adjuncts must be provided locally at the voice terminal or from a satellite closet through the terminal wiring. The following power supplies are currently recommended: nThe 1151A1 Power Unit and the 1151A2 Power Unit with Batter y Holdover have replaced the MSP-1 (WP92464L1) Power Supply, the KS-22911 L1/2,...
Page 64
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Adjunct Power 4-2 4 The distribution of power to the terminal equipment is provided by the 1146B distribution unit. The 1146B provides 32 standard 110 connections to the load with overcurrent protection and alarm lights. The 1145B1/1146B power arrangement is compact (measuring only 6.5 inches deep), lightweight, plastic enclosed, and designed for easy wall- or...
Page 65
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Adjunct Power 4-3 Information on the Older Power Supplies 4 Information on the Older Power Supplies The following diagram (Figure 4-1) shows the connections with the older power supplies including the MSP-1. NOTE: The 1151A1 and 1151A2 replace the MSP-1, the KS-22911 L1/2, 329A, the 353A DC power supplies, and the 2012D AC transformer.
Page 66
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Adjunct Power 4-4 Information on the Older Power Supplies 4 The Power Supplies Prior to the MSP-1 Figure 4-1. Local and Satellite Power Sources for Voice Terminals Adjuncts Wa ll PSLocal Power Supply: 2012D or 329A or KS-22911,L2 or KS-21239,L4/L5 or 353 or DS3081096 400B2 Terminal Terminal Information Outlet PS PS PS To Ve r t i c a l Trough KS-22911, 945, 329A, or...
Page 67
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Adjunct Power 4-5 Information on the Older Power Supplies 4 One of these power supplies must be used for each voice terminal equipped with one or more adjuncts. Each of these power supplies (except the 95B1) has a maximum cable distance of 250 feet (76 m) between the power supply and the adjunct(s). The maximum cable distance for the 95B1 is 150 feet (45m). Voice...
Page 68
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Adjunct Power 4-6 Information on the Older Power Supplies 4 NOTE: One power supply will support one telephone with or without an adjunct. The maximum loop range between the telephone and the power supply is 250 feet. This power supply replaces the KS-22911-L1/2, 329A, and 353A DC Power Supplies and the 2012D AC Transformer. The MSP-1 power supply has a single output of...
Page 69
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Adjunct Power 4-7 Information on the Older Power Supplies 4 nFigure 4-2 shows the local powering arrangement for: ISDN voice terminals; the DCP 7444 and 8434DX voice terminals’ VF displays; and adjuncts connected to all telephones except the 8102. nFigure 4-3 shows the local powering arrangement for adjuncts connected to the 8102 telephone. NOTE: The type of cord(s)...
Page 70
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Adjunct Power 4-8 The 1151A1 and 1151A2 Power Units 4 Figure 4-3. Local Powering Arrangement (Using the MSP-1) for Adjuncts Connected to the 8102 Analog Telephone The 1151A1 and 1151A2 Power Units The 1151A1 power supply is a single output 48 volt DC, 20 watt power supply. The 1151A1 operates from nominal AC input voltage (85 to 132 or 176 to 264) 50 or 60 Hz. This...