Page 241
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 231 Allocation of Buttons Digital set — 7401D/7401+ Digital set — 7403D Digital set — 7404D Digital set — 7404D w/display Digital set — 7405D Digital set — 7405D w/display Digital set — 7405D w/cov Digital set — 7406D Digital set — 7406D w/display Digital set — 7406+ Digital set — 7406+ w/display Digital set — 7407D Digital set — 7407+ Digital set — 7410D Digital set —...
Page 242
Technical Specifications 232 Allocation of Buttons DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Digital set — 8403B Digital set — 8405B/B+ Digital set — 8405D/D+ Digital set — 8410B Digital set — 8410D Digital set — 8411B Digital set — 8411D Digital set — 8434 D Digital set — 8434 with XM24B Expansion Module Digital set — 9403B Digital set — 9410D Digital set — 9434D184 64 352 124 352 124 352 676 964 184 352 676184 64 376 124 436 124 436...
Page 243
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 233 Allocation of Buttons ADJLK3 ADX8D ADX16A ADX16D ASAI CP9530 DIG800 K2500 MDC9000 MDW9000 PC4 568 76 568 4 76 568 76 52 52 4824 652 76 652 4 — 652 76 64 64 5804 568 76 568 — — — — — — — VRU 4 VRUFD VRUSA WCBRI 105TL76 62 62 24 2876 76 76 24 28— — — — — 1.Includes music-on-hold, recorded announcement, and loudspeaker paging. 2.The radio controller supports 24...
Page 244
Technical Specifications 234 Cabling Distances DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 The following notes apply to the button and data module records in Table 50: nAny DCP station (except 8400-series) can add a 7400B, requiring 1 data module record. nA data module can be added to a 7403D or 7405D, requiring 1 data module record. nA data module (ADM-T) can be added to a 7505D, 7506D, or 7507D, requiring 1 data module record. nAn...
Page 245
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 235 Cabling Distances 513, 610 BCT, 615 MT, 715, 2900/715, 715 BCS-2, 4410 or 4425 terminals (see also “data modules” or “EIA inter- face”). Maximum distance from termi- nal to data module or ADU 50 15.2 50 15.2 Data modules: Z702AL1-DSU data module base Z703AL1-DSU data module base 7404D data module DTDM High-speed data link MTDM 3270 data module 7400A/B data module...
Page 246
Technical Specifications 236 Cabling Distances DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Voice terminals: Analog 8-port circuit pack (TN742 or TN769), on-premises or out-of-building — same premises (notes 1 and 2) 500- or 2500- type (note 3) 7100 series 8100 series on/off premises and out of building20000 15200 152006100 4633 463313000 10000 100003962 3050 3050 16-port circuit pack (TN746/B or TN2183), on-premises only no...
Page 247
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 237 Cabling Distances Digital (TN2181 and TN2224), 2-wire 6400 series (cabling distance can increase to 5500 feet/1992 m using 22-AWG/0.32-mm 2 wire)3500 1066 2200 670 Digital (TN754) 7400D series On-premises-only Out-of-building, same premises Out-of-building, with Digital Line Pro- tectors3500 3500 50001066 1066 15242200 2200 4000670 670 1219 ISDN-BRI (TN556) 7500...
Page 248
Technical Specifications 238 Cabling Distances DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 ISDN-BRI Two-Wire Line Cabling Distances The TN2198 BRI 2-Wire line circuit pack supports various cabling configurations using 22, 24, and 26 AWG (0.34 mm2, 0.26 mm2, 0.14 mm2, respectively) wire. Up to 18,000 feet (5486m) (maximum) may be used between the TN2198 and the NT1 network interface. Refer to Table 52 for the cabling distances from the NT1...
Page 249
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 239 Cabling Distances Contact your Lucent Technologies representative for more information. For the maximum fiber optic cabling distances for a system, determine: nThe mean loss and the length of the outside plant fiber cable nThe mean loss and the length of fiber cable shipped with the cabinet (including any fiber riser cable) nThe mean loss of an ST connector and the...
Page 250
Technical Specifications 240 Initialization and Recovery DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 DS1 Remoting Transmission Distance When the distance between cabinets is greater than 115,000 feet or 22 miles (35 km), or if fiber optic cabling right-of-way is not available, use DS1 remoting for greater distances. Contact your Lucent Technologies representative for network engineering guidelines. Initialization and Recovery The time...