Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 211

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
191
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Assign Link via ppp Data Module to Switch 1
This task administers a ppp data module on Switch 2 for the ppp connection to Switch 
1. The data module associates a link number with a port address, extension number, 
and node name for the C-LAN port used for this connection.
Begin
Steps
> 
Open Data Module form — enter ad da 3020
>...

Page 212

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
192
> Submit the screen
End
COS:
The values for these fields will be specified by the system 
administrator. COR:
TN:
Node Name: The node name for the interface defined by this data module. 
This must be a name entered on the Node Names screen.
Subnet Mask:
Establish 
Connection?n means that the switch at the remote end of this connection 
(Switch 1...

Page 213

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
193
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on 
Switch 1.
Begin
Steps
> Open the Processor Channel Assignment form — enter  ch com p
> Enter values
change communications-interface processor-channels
                                                                    Page 1...

Page 214

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
194
> Submit the screen
End
Session - Local The Local and Remote Session numbers can be any value 
between 1 and 256 (si model) or 384 (r model), but they 
must be consistent between endpoints. For each 
connection, the Local Session number on this switch must 
equal the Remote Session number on the remote switch 
and vice versa.
It is allowed, and...

Page 215

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
195
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Assign IP Route to node-3
This task specifies a route for packets handled by node-2 that are destined for node-3. 
An IP route is required for this route because there are intermediate nodes between 
node-2 and node-3.
Begin
Steps
> Enable the ppp link on the node-2 data module screen: 
ch da 3020, set Enable Link? to y.
> Open the...

Page 216

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
196
Switch 3 Task — Assign Node Names
This task assigns node names and IP addresses to each node in the network. This 
screen is administered on Switch 3. A Node Names screen must be administered on 
each switch in the network.
The node names and IP addresses in any network should be assigned in a logical and 
consistent manner from the point of view...

Page 217

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
197
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 3 Task — Assign IP Interfaces
The IP interface for each C-LAN board on the switch must be defined on the IP 
Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces form.
Begin
Steps
> Open IP Interfaces form — enter  ch ip-i
> Enter values
change ip-interfaces  Page   1 of   2 
IP Interfaces
Inter-region IP...

Page 218

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
198
Subnet Mask Enter the subnet mask associated with the IP address for 
this IP interface. (The IP address is associated with the 
node name on the Node Names screen). 
In this example, leave the default subnet mask, 
255.255.255.0, which indicates no subnetting for a Class 
C IP address.
See the discussion of subnetting, Subnetting  (page 16), in...

Page 219

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
199
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 3 Task — Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module on Switch 3 for the ethernet connection 
to Switch 1. The data module associates a link number with a port address, extension 
number, and node name for the C-LAN port used for this connection.
Begin
Steps
> Open Data Module form — enter...

Page 220

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
200
Switch 3 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on 
Switch 3.
Begin
Steps
> Open the Processor Channel Assignment form — enter  ch com p
> Enter values
change communications-interface processor-channels
                                                                    Page 1...
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual

All Lucent Technologies manuals