Page 351
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 343 Philippines Philippines Ta b l e 4 6 shows the rec ommended c irc uit p ac ks. Table 46. Recommended and Available CPs in Philippines Equipment Equipment Type Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC DC-SCC AC-CMC AC Power Voltag e & Freq 220V/60Hz Ring Generator 20Hz/25Hz Tone Detec tor > TN2182B > TN748D Tone Cloc k > TN2182B R2MFC Circ uit TN744D Sp eec...
Page 352
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 344 Philippines 4 Wire Digital Line > TN754B 2 Wire Digital Line > TN2181 Data Line > TN726B BRI-U Line TN2198 BRI-ST Line TN556 Table 46. Recommended and Available CPs in Philippines Equipment Equipment Type Continued on next page
Page 353
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 345 Poland Poland The information p rovid ed here is p reliminary and sub jec t to c hang e. Ta b l e 4 7 shows the rec ommend ed c irc uit p ac ks. Table 47. Recommended and Available CPs in Poland Equipment Equipment Type Cab inet Typ e & Power GAC-MCC AC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 220V/50Hz Ring Generator 20Hz Tone Detec tor > TN2182B >...
Page 354
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 346 Poland NOTE: A-law c ompand ing is the national stand ard in Poland . However, Mu-law is used internally to the system for servic e c irc uits and analog lines. Network interfac es are c onfig ured as A-law if req uired . Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The...
Page 355
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 347 Poland Luc ent rec ommend s only the following c all typ es b e used outside North Americ a: System Parameter Administration Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nFeature-Related System Parameters Ad ministration — Trunk-to-Trunk Transfer:...
Page 356
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 348 Poland nUp p er Bound : 1100 msec nLower Bound : 600 msec n System Parameter Multifreq uenc y Sig naling Ad ministration — Incoming Call Type: group-ii-mfc — Outgoing Call Type: group-ii-mfc — Test Call Extension: Ac c ept d efault — Inc oming Interd ig it Timer: Ac c ep t default — Inc oming Sig nal Types: GROUP-I GROUP-II GROUP-A GROUP-B 11: ig nored 12: ig...
Page 357
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 349 Poland — Outgoing Signal Types: nSystem Parameters Country Op tions — Comp and ing Mode: A-law NOTE: Comp and ing Mod e: A-law is the national stand ard . Mu-law is used internal to the system for servic e c irc uits and analog lines. Network interfac es are c onfig ured as A-law if req uired . — Base Tone Generation Set: — Tone Detec tion Mod e: 5 —...
Page 358
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 350 Poland Analog Trunk Administration nCO Trunks — Trunk Group Sc reen nGroup Typ e: CO nCountry: nTrunk Gain: hig h nDirec tion: two-way nDig it Ab sorp tion List: b lank nPre f i x -1 : N o nTrunk Type: loop -start nOutg oing Dial Typ e: tone/rotary nTrunk Termination: 600 ohm nAuto Guard : No nDial Ac c ess: No nCall Still Held : No nTerminal Balanc ed...
Page 359
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 351 Poland nOutg oing Glare Guard : 1500 ms nOutg oing Dial Pulse Rate (PPS): 10 p p s nOutg oing Rotary Dig it Dial Make: 35 ms nOutg oing Rotary Dig it Dial Break: 65 ms nOutg oing Rotary Dial Interd igit: 800 ms nRing Monitor Timer: 5200 ms nInc oming Seizure: 500 ms nOutg oing End -of-Dial: 255 sec nOutg oing Seizure Resp onse: 0 nProg rammed Dial...
Page 360
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 352 Poland nExp ec ted Dig its: d ep end s on system size and numb ering plan nTerminal Balanc ed : yes nExtend ed Loop Range: (Used Only with TN459) no nDrop Treatment: silenc e nInc oming Rotary Timeout (sec ): 5 sec (This field will not b e used with CPs that c an ac c ept the Inc oming Partial Dial timer. Set this timer from the Ad ministrab le...