DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
153 Ecuador 
Ecuador
The information p rovid ed  here is p reliminary and  sub jec t to c hang e. Ta b l e  2 6 
shows the rec ommend ed  c irc uit p ac ks.
Table 26. Recommended and Available CPs in Ecuador
Equipment Equipment Type
Cab inet Typ e & Power GAC-MCC AC-MCC DC-MCC AC-SCC 
DC-SCC AC-CSCC AC-CMC
AC Power Voltag e & Freq 120V/60Hz 240V/60Hz
Ring  Generator...

Page 162

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
154 Ecuador 
NOTE:
A-law c ompand ing  is the national stand ard  in Ec uad or. However, 
Mu-law is used  internally to the system for servic e c irc uits and  
analog  lines. Network interfac es are c onfig ured  as A-law if req uired .
Feature Administration
The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e 
ap p roval was award ed ....

Page 163

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
155 Ecuador 
Luc ent rec ommend s only the following  c all typ es b e used  outside North 
Americ a:
System Parameter Administration
Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
nFeature-Related System Parameters Ad ministration
— Trunk-to-Trunk Transfer:...

Page 164

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
156 Ecuador 
nSystem Parameter Country Op tions Ad ministration
— Comp and ing  Mode: A-law
— Base Tone Generation Set: 
— Tone Detec tion Mod e: 2
— Interd ig it Pause: short
— Dig ital Loss Plan: 
— Analog Ringing Cadence: 
Analog Trunk Administration
nCO Trunks
— Trunk Group  Sc reen
nGroup  Typ e: CO 
nCountry: 
nTrunk Gain: hig h
nDirec tion: two-way 
nDig it Ab...

Page 165

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
157 Ecuador 
— Trunk Group  Ad ministration Sc reen (Timing )
Set the following  timers from the Administrab le Timers sc reen 
d uring ad ministration of eac h trunk g roup . Selec t the following  CO 
trunk timer values for this c ountry:
nInc oming  Disc onnec t: 100 ms
nOutg oing  Disc onnec t: 100 ms
nOutg oing  Dial Guard : 3000 ms 
nInc oming  Glare Guard : 1500...

Page 166

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
158 Ecuador 
nDisc onnec t Timing : 500 ms (This field  will not be used  with 
CPs that c an ac c ep t the Inc oming  Disc onnec t and  Outg oing  
Disc onnec t timers. Set these latter two timers from the 
Ad ministrab le Timers Sc reen.)
nDig it Treatment: b lank 
nDig its: b lank 
nExp ec ted  Dig its: d ep end s on system size and  numb ering  
plan
nTerminal...

Page 167

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
159 Ecuador 
nInterfac e Comp anding : A-law
nLine Cod ing: HDB3
nSignaling Mode: CAS
nCountry Protoc ol: 
nInterc onnec t: CO
nCRC?: No
nId le Cod e: 01010100 
— Trunk Group  Ad ministration Sc reen (Timing )
Dig ital trunk timing  values should  b e set as for analog  CO trunks.
nDID Trunks
— DS1 Ad ministration Sc reen
nCirc uit Pac k: TN464D (not entered as an ad...

Page 168

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
160 Ecuador 
— ISDN-PRI (Private Network) Sig naling
This examp le assumes use of US Op tion 1 with fac ility assoc iated  
sig naling . Other feature op tions will req uire c hang es in one or more 
ad ministered  items.
— DS1 Ad ministration sc reen
nCirc uit Pac k: TN464D (or TN464C from up g rad es)
nBit Rate: 2.048
nInterfac e Comp anding : A-law
nLine Cod ing:...

Page 169

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
161 France 
France
Ta b l e  2 7 shows the rec ommended  c irc uit p ac ks.
Table 27. Recommended and Available CPs in France 
Equipment Equipment Type
Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC AC-CSCC 
AC-CMC
AC Power Voltag e & Freq 220V/50Hz 
Ring  Generator 50Hz (See the note that follows this tab le.)
Tone Detec tor > TN2182B > TN744D
Tone Cloc k > TN2182B...

Page 170

DEFINITY® Enterprise Communications Server Application Notes 
for Type Approval    Issue 1
June 1999
Application Notes for Type Approval 
162 France 
NOTE:
50Hz ring  g eneration req uires modific ation to all b ac kp lanes with p ort slots 
and  installation of a TN2202 Ring  Generator (50Hz) c irc uit p ac k.
Also, you c an use the 122A Music -on-Hold  Interfac e in Franc e.
Feature Administration
The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e 
ap p roval was award ed...
Start reading Lucent Technologies Definity Application Notes For Type Approval Manual

Related Manuals for Lucent Technologies Definity Application Notes For Type Approval Manual

All Lucent Technologies manuals