Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies Audix Administration And Data Acquisition Guide
Lucent Technologies Audix Administration And Data Acquisition Guide
Here you can view all the pages of manual Lucent Technologies Audix Administration And Data Acquisition Guide. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 41
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Installation 2-7 Installation Procedures 2 4. Use the setup .exe p rog ram inc lud ed with the Stella Business Grap hic s p ac kag e to set up Stella to use either the Ep son d ot matrix p rinter or the Hewlett-Pac kard LaserJet printer. This entry must matc h the entry in the PC 2 A U D I X Se t u p Pa r a m e t e r s Pri n t e r Ty p e f i e ld . Check Config.sys and Autoexec.bat Files The installation...
Page 42
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Installation 2-8 Installation Procedures 2
Page 43
Using PC2AUDIX Application Programs 3-1 3 AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 3 Using PC2AUDIX Application Programs PC2AUDIX is a menu-d riven ap p lic ation that d ownload s selec ted voic e mail d ata to your PC, and works with d BASE III PLUS software to g enerate stand ard ized traffic and b illing rep orts. PC2AUDIX also p rovides tools for manag ing retrieved d ata on the PC. Using PC2AUDIX you c an: nRetrieve traffic and sub sc rib...
Page 44
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Using PC2AUDIX Application Programs 3-2 Working in PC2AUDIX 3 Working in PC2AUDIX Before using PC2AUDIX, you must first install the ADAP and PC2AUDIX software onto your PC following the installation instruc tions in Chap ter 2 . You also must install d BASE III PLUS software, as d esc rib ed in Chap ter 2 , to use PC2AUDIX. While working in PC2AUDIX you use sc reens to enter rep ort p arameters and g enerate rep...
Page 45
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Using PC2AUDIX Application Programs 3-3 Setting Up PC2AUDIX Interface in a New Work Area 3 NOTE: If you enter an invalid date in a d ate field , suc h as 99/99/99, dBASE III PLUS d oes not allow you to leave that field , and func tion keys (inc lud ing HELP) d o not func tion p rop erly. You c an either enter a valid d ate, or p ress the key to restore the d ate field to its initial value. Make c autious use of...
Page 46
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Using PC2AUDIX Application Programs 3-4 Setting Up PC2AUDIX Interface in a New Work Area 3 Establishing PC2AUDIX Setup Parameters Setup p arameters d efine the link b etween your PC and the voic e mail system from whic h your PC retrieves d ata. If you c reated subd irec tories for more than one system in the p revious task, you must also estab lish sep arate setup p arameters for eac h system. 1. At the DOS p romp...
Page 47
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Using PC2AUDIX Application Programs 3-5 Setting Up PC2AUDIX Interface in a New Work Area 3 Field Name Description Valid Entries Ty p e o f c onnec tionConnec tion typ e. Default: d irec tatt4000 (ATT4000 mod em) d irec t (hard wired c onnec tion using NULL modem) hayes (Hayes-c omp atible mod em) pdm (Modular Proc essor Data Module (MPDM) in c onjunc tion with your Luc ent Tec hnolog ies switc h)...
Page 48
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Using PC2AUDIX Application Programs 3-6 Setting Up PC2AUDIX Interface in a New Work Area 3 5. Press (CHANGE/RUN) to save the c hang es you have mad e to pag e 1 of the PC2AUDIX Setup Parameters. (You c an also wait until you have mad e all c hanges to p ag e 1 and p ag e 2 of this sc reen b efore saving .) ADAP log s into the voic e mail system to verify the switc h c onnec tion typ e and log s out ag ain. If you...
Page 49
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Using PC2AUDIX Application Programs 3-7 Setting Up PC2AUDIX Interface in a New Work Area 3 Field Name Description Valid Entries Printer Port The p ort on the PC whic h c onnec ts the local p rinter. Default: lp t1lp t1, lp t2, lp t3, c om2 none (no p rinter c onnec ted ; outp ut is d isp layed automatically on the PC screen). You may red irec t the p rinted outp ut from lp t1 to a serial p ort, COM n, using the...
Page 50
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Using PC2AUDIX Application Programs 3-8 Setting Up PC2AUDIX Interface in a New Work Area 3 AUDIX name for this siteName of the voic e mail system, your c omp any, or other id entifier whic h ap p ears in the head er information of rep orts generated by PC 2 A U D I X. d isp lay-only field Sw it c h c onnec tion typ eId entifies the type of c onnec tion b etween the switc h and the voic e mail system. A d...