Page 41

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Installation 
2-7 Installation Procedures 
2
4. Use the setup .exe p rog ram inc lud ed  with the Stella Business Grap hic s 
p ac kag e to set up  Stella to use either the Ep son d ot matrix p rinter or the 
Hewlett-Pac kard  LaserJet printer. This entry must matc h the entry in the 
PC 2 A U D I X Se t u p  Pa r a m e t e r s  Pri n t e r Ty p e  f i e ld .  
Check Config.sys and Autoexec.bat Files
The installation...

Page 42

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Installation 
2-8 Installation Procedures 
2 

Page 43

Using PC2AUDIX Application Programs 
3-1  
3
AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
3
Using PC2AUDIX Application 
Programs
PC2AUDIX is a menu-d riven ap p lic ation that d ownload s selec ted  voic e mail d ata 
to your PC, and  works with d BASE III PLUS software to g enerate stand ard ized  
traffic  and  b illing rep orts. PC2AUDIX also p rovides tools for manag ing  retrieved  
d ata on the PC. 
Using  PC2AUDIX you c an: 
nRetrieve traffic  and  sub sc rib...

Page 44

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Using PC2AUDIX Application Programs 
3-2 Working in PC2AUDIX 
3
Working in PC2AUDIX
Before using  PC2AUDIX, you must first install the ADAP and  PC2AUDIX software 
onto your PC following  the installation instruc tions in Chap ter 2
. You also must 
install d BASE III PLUS software, as d esc rib ed  in Chap ter 2
, to use PC2AUDIX. 
While working  in PC2AUDIX you use sc reens to enter rep ort p arameters and  
g enerate rep...

Page 45

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Using PC2AUDIX Application Programs 
3-3 Setting Up PC2AUDIX Interface in a New Work Area 
3
NOTE:
If you enter an invalid  date in a d ate field , suc h as 99/99/99, dBASE III 
PLUS d oes not allow you to leave that field , and  func tion keys (inc lud ing 
HELP) d o not func tion p rop erly. You c an either enter a valid  d ate, or p ress 
the   key to restore the d ate field  to its initial value. Make c autious use of...

Page 46

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Using PC2AUDIX Application Programs 
3-4 Setting Up PC2AUDIX Interface in a New Work Area 
3
Establishing PC2AUDIX Setup Parameters
Setup  p arameters d efine the link b etween your PC and the voic e mail system 
from whic h your PC retrieves d ata. If you c reated subd irec tories for more than 
one system in the p revious task, you must also estab lish sep arate setup  
p arameters for eac h system. 
1. At the DOS p romp...

Page 47

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Using PC2AUDIX Application Programs 
3-5 Setting Up PC2AUDIX Interface in a New Work Area 
3
  
Field Name Description Valid Entries
Ty p e  o f  
c onnec tionConnec tion typ e.
Default: d irec tatt4000 (ATT4000 mod em) 
d irec t (hard wired c onnec tion using NULL 
modem) 
hayes (Hayes-c omp atible mod em) 
pdm (Modular Proc essor Data Module 
(MPDM) in c onjunc tion with your Luc ent 
Tec hnolog ies switc h)...

Page 48

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Using PC2AUDIX Application Programs 
3-6 Setting Up PC2AUDIX Interface in a New Work Area 
3
5. Press   (CHANGE/RUN) to save the c hang es you have mad e to pag e 1 
of the PC2AUDIX Setup  Parameters. (You c an also wait until you have 
mad e all c hanges to p ag e 1 and  p ag e 2 of this sc reen b efore saving .) 
ADAP log s into the voic e mail system to verify the switc h c onnec tion typ e 
and  log s out ag ain.
If you...

Page 49

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Using PC2AUDIX Application Programs 
3-7 Setting Up PC2AUDIX Interface in a New Work Area 
3
 
Field Name Description Valid Entries
Printer Port  The p ort on the PC 
whic h c onnec ts the 
local p rinter.
Default: lp t1lp t1, lp t2, lp t3, c om2
none (no p rinter c onnec ted ; outp ut is 
d isp layed  automatically on the PC screen).
You may red irec t the p rinted  outp ut from lp t1 
to a serial p ort, COM
n, using  the...

Page 50

AUDIX Administration and Data Acquisition Package  585-302-502  Issue 14
May 1999
Using PC2AUDIX Application Programs 
3-8 Setting Up PC2AUDIX Interface in a New Work Area 
3
AUDIX name for 
this siteName of the voic e 
mail system, your 
c omp any, or other 
id entifier whic h 
ap p ears in the 
head er information 
of rep orts 
generated by 
PC 2 A U D I X.  d isp lay-only field
Sw it c h  
c onnec tion typ eId entifies the type 
of c onnec tion 
b etween the switc h 
and  the voic e mail 
system.
A d...