OPERATING INSTRUCTIONSB-8B-8 Wire Feed Motor AccelerationELECTRIC SHOCKcan kill. • Turn off input power to the welding power source using the disconnect switch before working on this equipment. The NA-5 has two different speeds of controlled wire feed motor acceleration. As shipped, the unit is connected for fast acceleration which is best for most applications. To change to the slower acceleration, turn off all input power to the NA-5 control box. Open the control box. Locate the Control PC Board...
Page 32
TABLE B.2 – STOPPING SEQUENCE SETTINGS. When “Stop” Button is Pressed Older Models Newer Models* Feed motor stops and Lead #693 to Pin 3 electrode burns back with Lead #690 to Pin 4 contactor delay (standard) Feed motor inches up and Lead #693 to Pin 1 electrode burns back with Lead #690 to Pin 4 contactor delay Feed motor inches up and Lead #693 to Pin 1 contactor opens Lead #690 to Pin 2 (no burnback) *NOTE: VOLTAGE CONTROL RESPONSE The NA-5 is provided with selectable voltage control response....
Page 33
AUTOMATIC SHUTDOWN If the NA-5 voltage control is unable to supply the “Set” value of the arc voltage while welding, the automatic shutdown circuit will activate. This protection circuit immediately returns the NA-5 control to idle state within a few seconds after the arc voltage discrepancy occurs. Typical causes that activate this protective shutdown circuit are as follows:1. “Set” value of arc voltage is outside the power source range. 2. Power source voltage control not set for “Remote”. 3....
Page 34
OPERATING INSTRUCTIONSB-11B-11 NA-5 In some cases, it is also possible to hold the “Actual” button pressed while starting the arc. Before the NA-5 shuts down, the actual arc voltage can be read on the digital meter. Comparing this reading to the “Set” reading will tell what change in the range controls of the power source are required so it can supply the desired voltage. Should the meter read zero, check the NA-5 sensing leads (#21 and #67) connections. Should the meter read negative (-) voltage,...
Page 35
OPERATING INSTRUCTIONSB-12B-12 NA-5 SECURITY OF WELD PROCEDURE SETTINGS There are two means provided to prevent or limit unauthorized readjustment of the NA-5 voltage and wire feed speed controls once set to the desired procedure.1. The security panel of the NA-5 can be locked to prevent access to the control knobs. 2. The control range of the procedure control knobs can be limited to either about 3% or about 15% of the full range control by installing a knob rotation stop screw to any or all of the...
Page 36
TABLE OF CONTENTS - ACCESSORIES SECTION - NA-5 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .\ . . . . . . . . . . . Section C General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .\ . . . . . . . . . C-2 Listing of Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 K29 Vertical Lift Adjuster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 K58 Magnetic Separator . . . . . . . . . . . ....
Page 37
C-2ACCESSORIESC-2 NA-5 Product NumberProduct Name K29 VERTICAL LIFT ADJUSTER K58 MAGNETIC SEPARATOR K96 HORIZONTAL ADJUSTER K129 SUBMERGED ARC SMALL WIRE TWINARC K148 CONTACT NOZZLE K149 LINC-FILL LONG STICKOUT EXTENSION K218 HORIZONTAL FILLET/LAP ATTACHMENT K219 FLUX HOPPER KIT K223 SOLENOID KIT K225 SUBMERGED ARC TWINARC KIT K238 HIGH FREQUENCY UNIT K239 TWINARC KIT FOR INNERSHIELD ELECTRODES K278 SPREADARC K281 SOLID WIRE STRAIGHTENER FOR TINY TWINARC K285 CONCENTRIC FLUX CONE K310 FLUX SCREEN K325...
Page 38
ACCESSORIESC-3C-3 NA-5 LISTING OF ACCESSORIES K29 VERTICAL LIFT ADJUSTER When mounted in the NA-5 head mounting system, the K29 Vertical Lift Adjuster provides quick hand crank adjustment of the vertical head position. It also has some horizontal adjustability as described in Sec. T3.2.3 of operator’s manual IM305. Installation instructions are shipped with each K29 Vertical Lift Adjuster kit, are contained in the IM305 manual, and can be ordered as Sec. T2.2.11. K58 MAGNETIC SEPARATOR Useful with any...
Page 39
ACCESSORIESC-4C-4 K225 SUBMERGED ARC TWINARC KIT The Twinarc kit provides for the feeding of two 5/64, 3/32, or 1/8 in. (1.98, 2.38, or 3.18 mm) solid wires through a single wire feeder. The electrode wire must be the same size. The assembly includes a wire reel, insulated reel mounting bracket, wire straightener, dual wire guides, nozzle, and contact block. Installation, operating, and maintenance instructions are shipped with each kit, are contained in the IM305 manual, and can be ordered as Sec....
Page 40
ACCESSORIESC-5C-5 NA-5 K334 START AND CRATER CONTROLS Easily installed procedure and timer boards to permit adjustment of wire speed and voltage. Can be installed to function at either the start of the weld or at the end for crater filling. Installation, operating, and maintenance instructions are shipped with each kit and can be ordered as Sec. T2.5.13 K334. K336 REMOTE INTERFACE MODULE Permits connection of customer-furnished remote start-stop and inch momentary contact closure or momentary 24...