Page 291
Repair information4-75 5060-4xx Installation notes To identify the color coded cable bands to the connectors, see “Transfer high voltage power supply (HVPS)” on page 5-20 . When installing the transfer HVPS board, route the cable to the HVPS input connector at CN1 (C) over the cable to the yellow transfer contact (D), under the cable to the magenta transfer contact (E), and attached to the cable tie (F). This makes sure the toroid (G) does not come into contact with the motor when the card is...
Page 292
4-76Service Manual 5060-4 xx Transfer plate assembly Go to “Transfer plate assembly” on page 7-12 for part number. 1.Remove the S2/narrow media/transparency/multipurpose feeder cable. See “S2/narrow media/transparency/multipurpose feeder cable” on page 4-70 . 2.Remove the transfer plate. Lifting and rotating the right edge of the plate up to a 45° angle releases the transfer plate. Remove the grounding strap (A) attached to the bottom of the transfer plate. 3.Remove the transfer plate assembly. A
Page 293
Repair information4-77 5060-4xx Vacuum transport belt (VTB) Go to “Vacuum transport belt assembly” on page 7-11 for part number. 1.Remove the transfer plate assembly. See “Transfer plate assembly” on page 4-76 . 2.Remove the fuser bottom duct. See “Fuser bottom duct” on page 4-36 . 3.Remove the two front screws (A). 4.Loosen belt (B) on redrive assembly and remove from redrive gear. 5.Remove belt from gear on vacuum belt transfer unit.
Page 294
4-78Service Manual 5060-4 xx 6.Rotate release lever on gear until the gear can be removed. 7.Remove screw from ground wire. 8.Remove vacuum belt transfer belt unit far enough to release ground wire from restraint clips and remove completly.
Page 295
Repair information4-79 5060-4xx Vacuum transport belt (VTB) fan Go to “VTB fan, 60 mm” on page 7-35 for part number. 1.Disconnect VTB fan from the system board. 2.Remove VTB fan with a flatblade screwdriver. Waste container door Go to “Waste container door” on page 7-5 for part number. 1.Open the waste container door. 2.Flex the door and remove it from the hinges (A). A
Page 296
4-80Service Manual 5060-4 xx Waste container latch Go to “Waste container latch” on page 7-26 for part number. 1.Remove the paper size sensing assembly. See “Paper size sensing assembly” on page 4-55 . 2.Use a flatblade screwdriver to release the waste container latch from the paper size sensing assembly. Web oiler fuser kit installation 1.Enter Diagnostic mode. See “Entering Diagnostics mode” on page 3-13 . 2.Select PRINTER SETUP . 3.Select Configuration ID . 4.Increase the last two digits each by...
Page 297
Repair information4-81 5060-4xx 7.Unlatch the two fuser latches (A). 8.Remove the fuser assembly. 9.Open the front cover. 10.Remove the yellow print cartridge. 11.Remove the front right light shield screws (B) and (C) and remove the light shield. A C(324)B(323)
Page 298
4-82Service Manual 5060-4 xx 12.Carefully remove the paper path access door cover right mounting screw (D). 13.Tape front jam access door (E) if tape is available, to help hold the door in place. 14.Remove the front right handle cover assembly screws (F) and remove the assembly. 15.Open paper tray.
Page 299
Repair information4-83 5060-4xx 16.Remove screw (G) from the top front support bracket. Swing bracket to the right. 17.Use the alignment pins (H) on the web oiler fuser motor assembly to position the assembly in holes (J) and install the assembly.
Page 300