Page 211
Diagnostic aids3-31 5060-4xx Disk Test/Clean Warning: This test destroys all data on the disk and should not be attempted on a good disk. This test may run approximately 1½ hours depending on the disk size. To run the Disk Test/Clean Test: 1.Select Disk Test/Clean from DEVICE TESTS in the Diagnostics mode. Files will be lost/Go or Stop? is displayed to warn the user. 2.To exit the test immediately and return to DEVICE TESTS, press Return or Stop . To continue with the test, press Go. If Go...
Page 212
3-32Service Manual 5060-4 xx PRINTER SETUP Defaults This setting is used by the printer to determine whether US or non-US factory defaults should be selected. The following printer settings have different US and non-US values: Warning: Modification of the printer setting Defaults causes the NVRAM space to be restored to the printer’s factory settings. PAGE COUNTS Color Page Count Mono Page Count Perm Page Count Setting the page counts The printer’s page count can be changed via the diagnostic...
Page 213
Diagnostic aids3-33 5060-4xx Viewing the permanent page count The permanent page count can only be viewed from the operator panel and cannot be changed. 1.Select Perm Page Count from PRINTER SETUP in the Diagnostics mode. 2.A screen similar to the following screen displays when permanent page count is selected: 3.Press Return to retur n to PRINTER SETUP in the Diagnostics mode. Serial Number You can view the serial number. Engine Setting x Warning: Should not be changed without specific...
Page 214
3-34Service Manual 5060-4 xx Reset Calibration The Reset Calibration resets the TPS NVRAM values when initiated. 1.Select Reset Calibration from PRINTER SETUP in the Diagnostics mode and the following screen displays: Then the following screen is displayed: 2.The printer returns to the previous screen when calibration is complete. Cal Ref Adj Warning: Should not be changed without specific instructions from the next level support. EP SETUP EP Defaults Fuser Temp DC Charge Adjustment Dev Bias Adj...
Page 215
Diagnostic aids3-35 5060-4xx ERROR LOG Display Log The error log provides a history of printer errors. The error log contains the 12 most recent errors. The most recent error appears in position 1 and the oldest error appears in position 12 (if 12 errors have occurred). If an error occurs after the log is full, the oldest error is discarded. Identical errors in consecutive positions in the log are entered. All 1 xx, 2xx and 9 xx error messages are stored in the error log. These errors are also...
Page 216
3-36Service Manual 5060-4 xx Clear Log To clear the Error Log: 1.Select Clear Log from ERROR LOG in the Diagnostics mode. 2.Select Ye s to clear the Error Log or No to exit the Clear Log menu. If Ye s is selected, the Empty Error Log displays on the screen. 3.Press Return or Stop to exit the Clear Log menu. EXIT DIAGNOSTICS Select EXIT DIAGNOSTICS to exit the Diagnostics mode and return to normal mode. HCIT standalone test mode This test lets you check out and test the HCIT (2000-Sheet High...
Page 217
Repair information4-1 5060-4xx 4. Repair information Warning: Read the following before handling electronic parts. Handling ESD-sensitive parts Many electronic products use parts that are known to be sensitive to electrostatic discharge (ESD). To prevent damage to ESD-sensitive parts, use the following instructions in addition to all the usual precautions, such as turning off power before removing logic boards: Keep the ESD-sensitive part in its original shipping container (a special “ESD bag”)...
Page 218
4-2Ser vice Manual 5060-4 xx Screw identification table The following table contains screw types, locations, and quantities necessary to service the printer. Pay careful attention to each screw type location when doing removals. You must install the correct screw type in each location during reassembly. Reference number Screw type Location Purpose Qty 002 4-40 Machine Parallel connector to shield Attach 2 102 M3.5x8 mm Thread Cutting Cartridge guides to upper frame Attach 8 Upper front cover to...
Page 219
Repair information4-3 5060-4xx 232 M3x6 mm Taptite Metal Thread Forming Ground cable to right front cover support and upper frame. Attach 2 Blank INA covers to system card shield Mounting 2 Rear V-block plate to upper frame Mounting 1 Transfer HVPS to card shield Attach 1 Media size card to support plate Attach 3 Black bellcrank studs Mounting 2 Ground cable to bottom support plate shield support assembly Attach 2 Rear cover to card shield Attach 6 Ground cable strap to system card shield...
Page 220
4-4Ser vice Manual 5060-4 xx 323 M3.5x8 mm Plastite Thread Forming (continued) Left lower cover to lower frame Attach 2 Left upper cover asm to lower frame Attach 2 Left upper cover asm to upper frame Attach 1 Left lower pivot to lower frame Attach 2 Left upper pivot lower frame Attach 1 Rear cover to lower frame, left cover Attach 6 Rear fan cover to lower frame and top cover Attach 4 RIP fan assembly to upper frame Attach 1 Cartridge contact caps to housing Attach 8 Rear cover to lower frame,...