Lexmark C 950 Service Manual
Here you can view all the pages of manual Lexmark C 950 Service Manual. The Lexmark manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 481
Repair information 4-47 5058-030 Go Back Previous Next Replacement warning: If reusing an existing developer unit assembly, ensure that all traces of old carrier (B) are removed from the developer unit assembly, or print quality issues may occur. B
Page 482
4-48 Service Manual 5058-030 Go Back Previous Next To install the new carrier (B): Warning: Ensure that the carrier is installed evenly and uniformly in the assembly, or spillage may occur. 1.Open the appropriate bag, and dump the appropriate carrier into the appropriate assembly. 2.Rotate the gears in the assembly to evenly distribute the carrier (B). Warning: Ensure that the two seals are properly positioned in the assembly before replacing the top cover (A), or spillage may occur which may lead...
Page 483
Repair information 4-49 5058-030 Go Back Previous Next 12.Lift the appropriate plastic gate, and push it in to reduce toner spillage. 13.Detach the lower portion (A) of the auger from the appropriate developer housing. 12 A
Page 484
4-50 Service Manual 5058-030 Go Back Previous Next 14.Swing away the lower portion of the auger to enable access to the two screws. 15.Remove the two screws (B) from the bracket. B
Page 485
Repair information 4-51 5058-030 Go Back Previous Next 16.Move the lever counterclockwise. 17.Remove the bracket mounted over the developer housing.
Page 486
4-52 Service Manual 5058-030 Go Back Previous Next 18.Remove the developer housing. Reinstallation warning: When reinstalling the developer housing, ensure that the printhead retract levers are in their uppermost position, or damage will occur to the machine. If the developer housing is installed correctly, the bracket (C) can be mounted over the developer housing without difficulty. Re-installation notes: C
Page 487
Repair information 4-53 5058-030 Go Back Previous Next •To complete the re-installation, do the following: a.Be sure to attach the lower part of the auger properly to reduce toner spillage. b.Move the lever clockwise. c.Pull the plastic gate (D), and move it to its lowest position. D
Page 488
4-54 Service Manual 5058-030 Go Back Previous Next •Move the appropriate wiper in and out to clean the printhead. Developer housing (K) removal 1.Remove the printer front door. See “Printer front door removal” on page 4-10. 2.Remove the transfer belt cleaner. See “Transfer belt cleaner removal” on page 4-175. 3.Remove the waste toner box. 4.Remove the four photoconductor units. 5.Remove the four toner supplies. 6.Remove the operator panel front cover. 7.Remove the printhead retract door. See...
Page 489
Repair information 4-55 5058-030 Go Back Previous Next 13.Detach the lower portion (A) of the auger from the appropriate developer housing. 14.Swing away the lower portion of the auger to enable access to the two screws. A
Page 490
4-56 Service Manual 5058-030 Go Back Previous Next 15.Remove the two screws (B) from the bracket. 16.Move the lever counterclockwise. B