Cleaning the Printer 6-4 Cleaning the Printer CAUTION Be sure to turn off the printer and unplug the power cord before cleaning. However, be sure to turn on the printer when cleaning the print head window. Exterior YMCK Ready Rotate TonerError Clear Control Panel Ventilation Grille Printer Exterior Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer6-5 Interior Cleaning the Media Feed Roller 1Open the top cover. If there is paper in the output tray, remove it, and then fold up the out - put tray before opening the top cover. 2Grab the handle and lift it up slightly to the back, and then slowly pull the imaging cartridge out vertically. Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer 6-6 Note Do not touch the PC drum on the imaging cartridge. Position the removed imaging cartridge horizontally as shows in the illustration at the right. Be sure to keep the imaging cartridge horizontal and place it where it will not become dirty. Do not leave the imaging cartridge removed for more than 15 minutes, and do not place the removed imaging cartridge in a location where it would be exposed to direct light (such as sunlight). 3Clean the media feed rollers by wiping them with a soft, dry cloth. BOTTOM VIEW Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer6-7 CAUTION The area around the fuser unit is extremely hot. Touching anything other than the indicated levers may result in burns. If you get burned, immediately cool the skin under cold water, and then seek professional medical attention. Note Decreased print quality may result if the surface of the transfer roller is touched. Be careful not to touch the surface of the transfer roller. BOTTOM VIEW Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer 6-8 4Slowly insert the imaging car- tridge vertically, and then push it slightly down toward you to fin - ish reinstalling the imaging car- tridge. 5Carefully close the top cover. Cleaning the Print Head Window 1Use either operation described below to switch the printer to Print Head Cleanup mode. zHold down the Rotate Toner key for 5 to 10 seconds. zOn the Panel tab of the Remote Panel Utility, click the P/H Clean Up button. The printer enters Print Head Cleanup mode, and the magenta toner indicator lights up. It is not possible to exit Print Head Cleanup mode before the oper- ation is finished (even if the Clear key is pressed). If the printer has incorrectly been switched to Print Head Cleanup mode, perform steps 2 through 4, then steps 10 through 14 (skip - ping steps 5 through 9) to exit Print Head Cleanup mode. Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer6-9 2Open the front cover. Before opening the front cover, open Tray 1 if it is not already open. 3The magenta toner cartridge has been moved to the position from where it can be replaced. Pull down the handle on the toner cartridge until the toner cartridge is unlocked and moves out slightly toward you. Remove the toner cartridge. When the magenta toner cartridge is removed, a gap is created within the printer so that the print head window can easily be cleaned. Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer 6-10 Note Do not touch the contact indicated in the illustration. 4Close the front cover. The toner cartridge rotate within the printer. 5After the toner cartridges have finished rotating and all indica - tors on the control panel begin blinking, open the top cover. Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer6-11 6Grab the handle and lift it up slightly to the back, and then slowly pull the imaging cartridge out vertically. Note Do not touch the PC drum on the imaging cartridge. Position the removed imaging cartridge horizontally as shows in the illustration at the right. Be sure to keep the imaging cartridge horizontal and place it where it will not become dirty. Do not leave the imaging cartridge removed for more than 15 minutes, and do not place the removed imaging cartridge in a location where it would be exposed to direct light (such as sunlight). Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer 6-12 7Clean the print head window by wiping it with a soft, dry cloth. CAUTION The area around the fuser unit is extremely hot. Touching anything other than the indicated levers may result in burns. If you get burned, immediately cool the skin under cold water, and then seek professional medical attention. BOTTOM VIEW Downloaded From ManualsPrinter.com Manuals
Cleaning the Printer6-13 Note Decreased print quality may result if the surface of the transfer roller is touched. Be careful not to touch the surface of the transfer roller. 8Slowly insert the imaging car- tridge vertically, and then push it slightly down toward you to fin - ish reinstalling the imaging car- tridge. BOTTOM VIEW Downloaded From ManualsPrinter.com Manuals