bizhub 652/5522-6 2.1 Accessing the Administrator Settings2 0While you are logging onto the Admin Mode using PageScope Web Connection, any operations from the machines control panel are disabled. 0If you have already logged on to the Admin Mode from the control panel or using PageScope Web Con- nection, the machine displays a message that tells that another administrator has previously logged on and rejects any attempt to log on to the Admin Mode using the PageScope Web Connection. Click [OK] and wait for some while before attempting to access the Admin Mode once again. 0If [Export to the device] operation is being executed using the PageScope Data Administrator, the ma- chine displays a message that tells you cannot log on to the mode because of the remote operation being performed and rejects any attempts to the Admin Mode via the PageScope Web Connection. Click [OK] and wait for some while before attempting to access the Admin Mode once again. 0If an attempt is made to log on to the Admin Mode while a job is being executed, the machine gives a message that tells that it is now impossible to log on to the Admin Mode. Click [OK] and try logging on to the Admin Mode after the execution of the job is completed. 0Do not leave the machine with the Admin Mode setting screen left shown on the display. If it is abso- lutely necessary to leave the machine, be sure first to log off from the Admin Mode. 0If you have logged on to the Admin Mode using the PageScope Web Connection and if you close the web browser without clicking [Logout], the touch panel of the machine remains locked for 70 sec. 0The display modes of the PageScope Web Connection administrator modes are classified into two dis- play modes: [Tab Function Display] and [List Function Display]. This manual shows an example where the [List Function Display] is set as the display mode. In either display mode, the available items are the same. 1Start the Web browser. 2Enter the IP address of the machine in the address bar. 3Press the [Enter] key to start PageScope Web Connection. 4Click the Administrator radio button and [Login]. Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-7 2.1 Accessing the Administrator Settings2 5Select Administrator (Admin Mode) or Administrator (User Mode) and enter the 8-digit Administrator Password in the Password box. %If Administrator (Admin Mode) is selected, the settings for the machine system and network can be registered or changed. %If Administrator (User Mode) is selected, you can log on to the User Mode as an Administrator. In the User Mode, you can check or delete a job, which is disabled in Administrator Settings. Note, however, that the authority relating to box settings is the same as that of Administrator Settings. %When accessing the Admin Mode using the PageScope Web Connection, enter the same Adminis- trator Password as that for the machine. 6Click [OK]. %If a wrong Administrator Password is entered, a message that tells that the authentication has failed appears. Enter the correct Administrator Password. %If the Enhanced Security Mode is set to [ON], entry of a wrong password is counted as unauthorized access. If a wrong Administrator Password is entered a predetermined number of times (once to three times) or more set by the Administrator of the machine, a message appears saying that the machine accepts no more Administrator Passwords because of unauthorized access for any sub- sequent entry of the Administrator Password. The machine is then set into an access lock state. To cancel the access lock state, settings must be made by the Service Engineer; or, turn off, and then turn on, the main power switch of the machine. If the main power switch is turned off and on, the access lock state is canceled after the lapse of time set for [Release Time Settings]. When the main power switch is turned off, then on again, wait at least 10 seconds to turn it on after turning it off. If there is no wait period between turning the main power switch off, then on again, the machine may not function properly. Here is the sequence, through which the main power switch and sub power switch are turned on and off: Turn off the sub power switch ö Turn off the main power switch ö Turn on the main power switch ö Turn on the sub power switch 7Click [Logout]. 8Click [OK]. This allows you to log off from the Admin Mode. Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-8 2.2 Enhancing the Security Function2 2.2 Enhancing the Security Function When access to the machine by the Administrator of the machine through the Administrator Settings from the control panel is authenticated, the machine enables setting of the Enhanced Security Mode that allows settings for enhancing each of different security functions to be converted all at once. In the Enhanced Security Mode, the machine allows selection of whether to use the Enhanced Security Mode or not. If the Enhanced Security Mode is set to [ON], a count is taken of the number of unauthorized accesses to the Administrator Settings, User Authentication, Account Track, SNMP authentication, WebDAV authenti- cation, all Secure Print, and all User Boxes. A function is also set that determines whether each password meets predetermined requirements. The security function is thus enhanced in the Enhanced Security Mode. The following settings must first be made before the Enhanced Security Mode is set to [ON]. NOTICE First, set the Encryption Key. To set the Encryption Key, HDD Format must first be executed. Execution of the HDD Format clears various setting values. For details of items that are cleared by HDD Format, see page 2-10. If initialization is executed by the Service Engineer, set the Administrator Password and turn [ON] the En- hanced Security Mode again. Settings to be Made in AdvanceDescription Administrator Password An 8-digit password that meets the Password Rules. The factory setting is 12345678. User Authentication Set to either [ON (MFP)] or [ON (External Server)] (Active Directory). Encryption Key Set the 20-digit Encryption Key. Certificate for SSL Register the self-signed certificate for SSL communications. Service settings Calls for setting made by the Service Engineer. For details, contact your Service Representative. Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-9 2.2 Enhancing the Security Function2 Setting the Enhanced Security Mode to [ON] changes the setting values of the following functions. Function NameFactory SettingWhen Enhanced Security Mode is set to [ON] Password Rules Invalid Enable (not to be changed) Prohibited Functions When Authentication Er- rorMode 1 Mode 2 (not to be changed): Three times is set. * The number of times can be changed to once, twice, or three times (twice, four times, or six times for the WebDAV Server Password). Confidential Document Access MethodMode 1 Mode 2 (not to be changed) * In association with Prohibit Functions When Authenti- cation Error the method is changed from authentication using Secure Print ID and password (Mode 1) to that us- ing the password with the Secure Print Document first narrowed down by Secure Print ID (Mode 2). Public User Access Restrict Restrict (not to be changed) User List OFF OFF (not to be changed) Print Without Authentica- tionRestrict Restrict (not to be changed) User Box Admin. Setting Restrict Restrict (not to be changed) SSL OFF ON (not to be changed) SSL Encryption Strength AES-256, 3DES-168, RC4-128, DES-56, RC4-40AES/3DES (not to be changed to one containing strength lower than AES/3DES) Automatically Obtain Cer- tificates of S/MIMENo No (not to be changed) S/MIME Encryption Method3DES 3DES (not to be changed to DES or RC-2) FTP Server ON OFF (not to be changed) SNMPv1/v2c Read/Write en- abledOnly Read is enabled (not to be changed) SNMP v3 Security Level and auth-password/priv- passwordauth-password/ priv-passwordThe security level can be selected from among [auth- password] and [auth-password/priv-password]. An 8-digit-or-more auth-password and priv-password can both be set. Print Data Capture Allow Restrict (not to be changed) Network Setting Clear (Pagescope Web Con- nection)Enabled Restrict Administrator Password Change Via Network (Pagescope Web Con- nection)Enabled Restrict Release Time settings 5 min. The setting value should be 5 min. or more (no value less than 5 can be set) Change by the user of destination data previ- ously registered (Address Book and Program)Allow Restrict (not to be changed) Secure Print User Box PreviewThumbnail View, Detail View, and Document De- tails are enabledOnly Detail View is enabled before password authenti- cation (Mode 2) Initialize (Network Set- tings)Enabled Restrict (not to be changed) Image Log Transfer Set- tingsOFF OFF (not to be changed) Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-10 2.2 Enhancing the Security Function2 NOTICE When Password Rules is set to [ON] the characters and the number of digits used for each password are restricted. For details of the Password Rules, see page 1-8. 2.2.1 Items cleared by HDD Format Following are the items that are cleared by HDD Format. Whenever HDD Format is executed, be sure to set the Enhanced Security Mode to [ON] again. 2.2.2 Setting the Enhanced Security Mode 0For the procedure to call the Administrator Settings on the display, see page 2-2. 0Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings. 0The Enhanced Security Mode is factory-set to [OFF]. Be sure to turn [ON] the Enhanced Security Mode so as to enable the security function of the machine. 1Call the Administrator Settings on the display from the control panel. 2Touch [Security Settings]. CS Remote Care Usable Remote device setting disabled Function NameFactory SettingWhen Enhanced Security Mode is set to [ON] Items of Data ClearedDescription Enhanced Security Mode Set to [OFF] Device certificate (SSL certificate)Deletes the device certificate (SSL certificate) registered in the machine. User Authentication Set to [OFF] Account Track Authentica- tionSet to [OFF] Public User AccessSet to [Restrict] User List Set to [OFF] Print Without Authentica- tionSet to [Restrict] User registration data Deletes all user-related data that has been registered Account Track registration dataDeletes all account track-related data that has been registered Box registration data/fileDeletes all User Box-related information and files saved in User Box Secure Print ID/Pass- word/DocumentDeletes all Secure Print Document-related information and files saved Destination recipient data filesDeletes all destination recipient data including e-mail addresses and tele- phone numbers Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-11 2.2 Enhancing the Security Function2 3Touch [Enhanced Security Mode]. 4Select [ON] to enable the Enhanced Security Mode and touch [OK]. %The following screen appears if the previously required settings are yet to be made by the Admin- istrator of the machine. Make the necessary settings according to the corresponding set procedure. %The following screen appears if the previously required settings are yet to be made by the Service Engineer. Contact your Service Representative. Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-12 2.2 Enhancing the Security Function2 5Touch [OK]. 6Make sure that a message appears prompting you to turn OFF and then ON the main power switch. Now, turn OFF and then turn ON the main power switch. %When the main power switch is turned off, then on again, wait at least 10 seconds to turn it on after turning it off. if there is no wait period between turning the main power switch off, then on again, the machine may not function properly. Here is the sequence, through which the main power switch and sub power switch are turned on and off: Turn off the sub power switch ö Turn off the main power switch ö Turn on the main power switch ö Turn on the sub power switch %If the Enhanced Security Mode is properly set to [ON], the following icon appears at the center of the User Authentication screen, indicating that the machine is in the Enhanced Security Mode. Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-13 2.3 Preventing Unauthorized Access2 2.3 Preventing Unauthorized Access When access to the machine by the Administrator of the machine through the Administrator Settings from the control panel is authenticated, the machine enables setting of the operation of Prohibited Functions When Authentication Error. The machine then takes a count of the number of unsuccessful accesses to the Admin- istrator Settings, User Authentication, Account Track, SNMP authentication, WebDAV authentication, Secure Print authentication, and User Box authentication to prohibit the authentication operation. Either [Mode 1] or [Mode 2] can be selected for Prohibited Functions When Authentication Error. The factory setting is [Mode 1]. If the Enhanced Security Mode is set to [ON], it is prohibited to change the setting from [Mode 2] (check count: three times). It is nonetheless possible to change the check count to select from among once, twice, or three times (twice, four times, or six times for the WebDAV authentication). If [Mode 2] is selected, the Release Time Settings function is enabled. When the Administrator Settings is set into the access lock state, the main power switch is turned off and on and, after the lapse of a predetermined period of time after the machine is turned on again, the access lock state of the Administrator Settings is can- celed. The Release Time Settings function allows the period of time, after the lapse of which the access lock state of the Administrator Settings is canceled, to be set in the range between 1 and 60 min. The factory set- ting is 5 min. For details of each mode, see the table below. NOTICE If the access lock state of the Administrator Settings is canceled by the Service Engineer, the setting of the Release Time Settings function is not applied. Setting Prohibited Functions When Authentication Error 0For the procedure to call the Security Settings screen on the display, see steps 1 and 2 of page 2-10. 0Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings. 1Call the Security Settings screen on the display from the control panel. 2Touch [Security Details]. ModeDescription Mode 1 If authentication fails, the authentication operation (entry of the password) is prohibited for 5 sec. Mode 2 If authentication fails, the authentication operation (entry of the password) is prohibited for 5 sec. The number of times, in which authentication fails, is also counted and, when the failure count reaches a predetermined value, the authentication operation is prohibited and the machine is set into an access lock state. Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-14 2.3 Preventing Unauthorized Access2 3Touch [Prohibited Functions When Authentication Error]. 4Touch [Mode 2]. %To change the check count, touch [+] to increase the count or [-] to decrease it. 5Touch [Release Time Settings]. 6Press the [C] key and, from the keypad, enter the time, after the lapse of which the access lock state of the Administrator Settings is canceled. %Release Time can be set to any value between 1 min. and 60 min. in 1-min. increments. An input data error message appears when any value falling outside the range of 1 to 60 min. is set. Enter the correct Release Time. %In the Enhanced Security Mode, Release Time less than 5 min. cannot be set. 7Touch [OK]. Downloaded From ManualsPrinter.com Manuals
bizhub 652/5522-15 2.4 Canceling the Operation Prohibited State2 2.4 Canceling the Operation Prohibited State When access to the machine by the Administrator of the machine through the Administrator Settings from the control panel is authenticated, the machine enables the operation of Release Setting performed for can- celing the state of Prohibited Functions When Authentication Error (access lock state) as a result of unautho- rized access. Release Setting clears the unauthorized access check count for all User Authentication, Account Track, SNMP authentication, WebDAV authentication, all Secure Print authentication, and all User Box authentica- tion, resetting it to zero and canceling the operation prohibited state. Perform the following procedure to can- cel the operation prohibited state. Performing Release Setting 0For the procedure to call the Security Details screen on the display, see steps 1 and 2 of page 2-13. 0Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings. 0When the main power switch is turned off, then on again, wait at least 10 seconds to turn it on after turning it off. if there is no wait period between turning the main power switch off, then on again, the machine may not function properly. Here is the sequence, through which the main power switch and sub power switch are turned on and off: Turn off the sub power switch ö Turn off the main power switch ö Turn on the main power switch ö Turn on the sub power switch 1Call the Security Details screen on the display from the control panel. 2Touch [Prohibited Functions When Authentication Error]. Operation Prohibited StateCanceling procedure Administrator Settings • The Service Engineer presses the [Administrator unlocking] key to cancel the operation prohibited state. • The operation prohibited state is canceled after the main power switch is turned off and on and the period of time set in [Re- lease Time Settings] elapses. User/Account authentication The Administrator presses the [Release] key to cancel the opera- tion prohibited state. Secure Print authentication User Box authentication SNMP authentication WebDAV authentication Downloaded From ManualsPrinter.com Manuals