Page 41
TK-860G/862G PARTS LIST 41 Ref. No.AddressParts No. Description Ref. No.AddressParts No. DescriptionNewDesti-partsnationNewDesti-partsnation TX-RX UNIT (X57-5960-XX) PLL/VCO (X58-4670-XX) Q19 DTC114EKA DIGITAL TRANSISTOR Q20 DTA114EKA DIGITAL TRANSISTOR Q21 DTC114EKA DIGITAL TRANSISTOR Q22 2SC4093 TRANSISTOR Q23 2SA1641(S,T) TRANSISTOR Q24 DTA114EKA DIGITAL TRANSISTOR Q25 2SC3357 TRANSISTOR Q26 DTA114EKA DIGITAL TRANSISTOR Q27 2SC2954 TRANSISTOR Q28 2SB1132(Q,R) TRANSISTOR Q29 DTC114EKA DIGITAL...
Page 42
42 TK-860G/862G EXPLODED VIEW (TK-860G) Parts with the exploded numbers larger than 700 are not supplied. 1 2 A BC 1 24 3 24 2 40377 116 17 18 22 22 23x2 27 249 25 14 12 21x2 44 26 IC400 16 701 Cx2 702 703 A A C Ax2C 703 TX-RX unit (X57-595) (B/2) TX-RX unit (X57-595) (A/2) Display unit (X54-327) 704 Dx11Cx2B B A M2.6 x 6 (OC) BLK : N33-2606-45 B M3 x 8 : N67-3008-46 C M2.6 x 6 (Br-Tap) : N87-2606-46 D M2.6 x 12 (Br-Tap) : N87-2612-46
Page 43
43 TK-860G/862G EXPLODED VIEW (TK-862G) 1 2 D EF 1 24 3 24 2 4037 116 728 17 18 22 22 23x2 27 249 25 14 12 21x2 44 26 IC400 16 701 702Cx2 A A Ax2C CB B Cx2 Dx11 703 703 TX-RX unit (X57-595) (B/2) TX-RX unit (X57-595) (A/2) Display unit (X54-328) 704 A M2.6 x 6 (OC) BLK : N33-2606-45 B M3 x 8 : N67-3008-46 C M2.6 x 6 (Br-Tap) : N87-2606-46 D M2.6 x 12 (Br-Tap) : N87-2612-46 Parts with the exploded numbers larger than 700 are not supplied.
Page 44
44 TK-860G/862G PACKING Parts with the exploded numbers larger than 700 are not supplied. G H 1 2 3 5 Cap (B09-0235-05) 8 Instruction manual (B62-1257-10) : M (B62-1258-00) : K,K3705 Warranty card 13 DC cord (E30-3339-05) 19 Fuse (10A) (F51-0016-05) x 2 30 Polystyrene foamed fixture (F) (H10-6618-12)31 Polystyrene foamed fixture (R) (H10-6619-12) 32 Inner packing case (H12-1391-03)33 Protection bag (H25-0720-04) 33 Protection bag...
Page 45
45 TK-860G/862G ADJUSTMENT Test Mode (TK-860G Only) Test Mode Operating Features This transceiver has a test mode. To enter test mode, press [SCN] key and turn power on. Hold [SCN] key un- til test channel No. and test signalling No. appears on LCD. Test mode can be inhibited by programming. To exit test mode, switch the power on again. The following func- tions are available in test mode. • Controls [PTT] Used when making a transmission. [MON] Monitor on and off. [SCN] Sets to the tuning mode....
Page 46
46 TK-860G/862G FREQ_ _XX Frequency adj. Display Function name HPOW_XXX RF high powerH.POW_XXX Hi power (L)H.P.OW_XXX Hi power (L) [A] [D/A] [D/A] [D/A] [D/A] [D/A] H.P.O.W_XXX Hi power (C)H.P.O.W._XXX Hi power (H)H.P.O.W._.XXX Hi power (H) LPOW_XXX RF low powerL.POW_XXX Low power (L)L.P.OW_XXX Low power (L) [A] L.P.O.W_XXX Low power (C)L.P.O.W._XXX Low power (H)L.P.O.W._.XXX Low power (H) _MAX_XXX Max deviation (Wide)_.MAX_XXX Max deviation (L)_MAX_ XXX. Max deviation (Narrow) [A] _.M.A.X_XXX Max...
Page 47
47 TK-860G/862G Test Equipment Required for Alignment Test Equipment Major Specifications 1. Standard Signal Generator Frequency Range 400 to 520MHz (SSG) Modulation Frequency modulation and external modulation Output –127dBm/0.1µV to greater than –7dBm/100mV 2. Power Meter Input Impedance 50Ω Operation Frequency 400 to 520MHz or more Measurement Capability Vicinity of 100W 3. Deviation Meter Frequency Range 400 to 520MHz 4. Digital Volt Meter Measuring Range 1 to 20V DC (DVM) Accuracy High input...
Page 48
48 TK-860G/862G ADJUSTMENT Adjustment Location Switch (TK-860G)Adjustment Point Note • Flash memory The firmware program (User mode, Test mode, Tuning mode, etc.) and the data programmed by the FPU (KPG-56D) for the flash memory, is stored in memory. When parts are changed, program the data again. • EEPROM The tuning data (Deviation, Squelch, etc.) for the EEPROM, is stored in memory. When parts are changed, readjust the transceiver. Repair Jig • Chassis Use jig (Part No. : A10-4010-02) for...
Page 49
49 ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item TK-860G/862G Receiver Section 1.Discriminator1) Set test mode SSG Rear ANT TX-RX L5AF output maximum.• Wide CH : CH1 - Sig1 panel (A/2) SSG output : –53dBm/501µV AF VTVM ACC SSG MOD : 3kHz Oscilloscope(EXT.SP) AF : 1.4V/4Ω 2) SSG MOD : OFF DVM TX-RX IC5 9pin 0.7V DC (A/2) 2. Sensitivity 1) Set test mode SSG Rear ANT TX-RX L13 RSSI voltage • Wide Select “SENS” in tuning mode.panel (A/2)...
Page 50
ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item 50 TK-860G/862G 3. Squelch 3 1) Set test mode SSG Rear ANT FrontCH/Adjust to the • WideSelect “SQL3” in tuning mode.panel panel squelch threshold “S.QL3” AF VTVM ACC point. Adjust [ ***] Distortion (EXT.SP) SSG freq' meter : 450.050MHzK,M Oscilloscope: 400.050MHzK3AGSSG output : –125dBm/0.12µVSSG MOD : 3kHz (Wide) 1.5kHz (Narrow) 2) “S.Q.L.3” Adjust [ ***] SSG freq' :...