    							Display Setup
    Back Color
    For setting the  color of the background  to “Blue” or “Black” when there is no input  signal.
    Menu Position
    For setting the  display position  of the menu.
    Menu Display
    Setting Description
    15sec The menu display disappears if it is not operated  for 15 seconds.
    On Displays the menu at  all times.
    Line  Display
    Setting Description
    5sec Shows the input terminal  for 5 seconds  when input is switched.
    Off Not displayed.
    Source Display
    Setting Description
    On Displays the signal  when input is switched.
    Off Not displayed.
    Logo
    Setting Description
    On Displays the “D­ILA” logo for 5 seconds during  startup.
    Off Not displayed.
    Language
    For setting the display language  to “ÔŠ ”, “English”, “Deutsch”, “Español”, “Italiano”,  “Français”, “Português”,
    “Nederlands”, “Svenska”,  “Norsk”, “Русский”, “¤”, or “
    _j¤”.
    61
    Adjust/Set 
    						
    							Function
    Trigger
    For configuring 12 V output to an external  screen equipped with a trigger function.
    Setting Description
    Off No output.
    On (Power) Outputs control signals  (12 V) from the  trigger terminal  when the power is turned
    on.
    After the  power is turned off, output  stops when the unit shifts to the Standby
    mode after cooling is complete.
    You  can also  output  signals  in  the  Standby  mode by pressing  the  [OK]  button.
    On (Anamo) Outputs control  signals  when  the “Anamorphic”  setting is  switched  from “Off” to  “A”
    or “B”.
    Off  Timer
    For setting the  timing to power off the unit automatically  (“1 Hour”, “2 Hours”,  “3 Hours”, or “4 Hours”)  when it is not
    operated  for a period of time.
    High Altitude  Mode
    Set  to “On” when using the  projector at a location of low atmospheric pressure  (higher than 900 m above sea level).
    ECO Mode
    Setting Description
    On Minimizes power consumption in the Standby mode.
    If there  is  no  signal  transmission  or operation  for  30 minutes  while an image  is
    projected,  the power is turned off automatically.
    Off Set to “Off”  if  RS­232C  /  LAN  communication  is performed  or the  HDMI  link function
    is used in the  Standby mode.
    Communication  Terminal
    For setting the  external control terminal  to be used to “RS­232C”  or “LAN”.
    Network
    Setting Description
    DHCP Client On Obtains the IP  address  automatically  from  the DHCP  server inside  the connected
    network.
    Off For configuring  the network settings manually.
    IP Address For configuring the IP address.
    Subnet Mask For configuring the subnet mask.
    Default  Gateway For configuring  the default  gateway.
    MAC Address Displays the MAC address of the unit.
    Set Applies the network  settings.
    62
    Adjust/Set 
    						
    							Remote Code
    For  changing  the remote control  code.
    You need to configure the  remote control according to the settings of this unit.
    On the  remote control  unit, press  the [MENU]  and [BACK] buttons  at the  same time for three seconds  or longer to
    switch  the code.
    The backlight of the remote control  blinks 3 times: change the remote control  code to “A”
    The backlight of the remote control  blinks 2 times: change the remote control  code to “B”
    Setting Description
    A Change the remote control  code from “B” to “A”.
    B Change the remote control  code from “A” to “B”.
    Lamp  Reset
    For resetting the  lamp time to “0”.
    ¨ “Resetting the  Lamp Time”  
    ¢p. 67£
    Glossary of Network Terminology
    DHCP : Abbreviation for  Dynamic  Host  Configuration  Protocol. This is  a protocol  for  the network
    to assign an  IP address automatically  to the connected device.
    IP Address : Numeric characters for identifying the device that is connected to the network.
    Subnet Mask : Numeric characters  that define the  bit count used for the network address that is a
    segment of the IP address.
    Default  Gateway :
    
    Server  for communicating beyond the  network that is divided by the subnet mask.
    MAC Address : Abbreviation for Media  Access  Control  address.  This is  a number  that is unique  to  each
    network  adapter.  Each of the  network  adapters  is assigned  with  a unique  MAC  address.
    63
    Adjust/Set 
    						
    							Information
    During video  signal  input
    Setting Description
    Input Displays video input terminal.
    Source Displays the input source.
    Deep  Color Displays the color bit depth of the input  video signal.
    Not displayed when YCbCr(4:2:2) is input.
    Displayed when Deep  Color information is received  from the source device.
    Lamp  Time Displays the lamp  time.
    Soft Ver. Displays the firmware version.
    During PC  signal  input
    Setting Description
    Input Displays video input terminal.
    Resolution Displays the image  resolution.
    H Frequency Displays the horizontal frequency.
    V Frequency Displays the vertical frequency.
    Deep  Color Displays the color bit depth of the input  video signal.
    Not displayed when YCbCr(4:2:2) is input.
    Displayed when Deep  Color information is received  from the source device.
    Lamp  Time Displays the lamp  time.
    Soft Ver. Displays the firmware version.
    64
    Adjust/Set 
    						
    							Replacing the Lamp
    The lamp is a consumable item. If the  image appears  dark or the  lamp goes out, replace the  lamp unit.
    When the lamp  replacement time approaches, the user is notified  with a message displayed on the screen and by
    the  indicator.  (p. 81)
    Lamp  Replacement  Procedure
    CAUTION
    Do  not  insert  your  hands  into  the opening  of the  lamp.
    This  could  cause  significant deterioration in the
    performance  of the equipment, or lead  to injury and
    electric shock.
    Do  not  replace  the lamp  immediately  after  the unit  has
    been  used.  Allow  a cooling  period of at least  one hour
    before  replacement. The temperature of the lamp  is
    still high, and may  cause burn injuries.
    Do not subject the  lamp unit to shock.  Doing so may
    cause  lamp blowout.
    Do not  use  a flammable  air  duster  to  clean  the internal
    parts  of the unit.  Doing so may  cause fire.
    Use only  genuine  replacement  parts for  the  lamp  unit.
    Also, never  attempt to reuse  an old  lamp  unit. This
    may  cause the  unit to malfunction.
    Do not  touch  the  surface  of  a new  lamp.  Doing  so may
    shorten  the lamp  life and cause lamp  blowout.
    When replacing the lamp, be careful not to injure
    yourself as the lamp  may be broken.
    When replacing the lamp  of a projector suspended
    from the  ceiling, work at  height is required.  This is a
    dangerous operation. Please  consult our service
    center.
     Pull
     out  the power  plug from  the power
    outlet
     Remove  the lamp  cover
    Remove  the screws  with a t screwdriver.
    .
    
    Loosen  the screws  of the lamp  unit
    Loosen the screws with a  t screwdriver.
    .
    
    Pull  out the  lamp unit
    Grasp the  handle and pull out the  lamp unit.
    .
    Handle
    65
    Maintenance 
    						
    							Install the  new lamp  unit
    .
    Handle
    Tighten
     the screws of the new lamp
    unit
    Tighten  the screws with a  t screwdriver.
    .
    
    Attach  the lamp  cover
    Insert  the two tabs at  the top and bottom of the
    lamp  cover into the  unit.
    Tighten the screws with a t screwdriver.
    .
    MEMO
    Usable  lamp  life
    When  the lamp  is  used  with “Lamp  Power”  set  to “Low”
    ,  the  lamp  life  on this  unit  is approximately  4000  hours.
    This  is  the  average  usable  time  and not a guaranteed
    value.
    The  lamp  life  may  not  reach  4000 hours  depending  on
    the  operating conditions.
    When  the lamp  has  reached  the end  of its  usable  life,
    deterioration progresses rapidly.
    When the video image  appears dark, when the color
    tone looks unnatural, or when the image  flickers,
    replace the  lamp unit with a new one promptly.
    Purchasing  a lamp  unit
    Please  consult  your authorized  dealer or nearby service
    center.
    Lamp  unit
    Product  no.: PK ­L2312U
    *
    Lamps  with a different  product  number  or those  for  other
    projector models  cannot be used.
    Information  about  the  lamp
    An ultra ­high pressure  mercury lamp with a high internal
    pressure  is used in the  projector.
    Due to the  characteristics  of this lamp, it may blow out
    with a loud noise or go out when it is subject to shock or
    after  using  for  a prolonged  period of time  (the time  before
    the  lamp  blows out or goes out varies  considerably with
    each lamp  as well  as the  operating conditions).
    After  replacing  the  lamp
    Do not place the  removed lamp unit at a place that is
    within  reach by children  or anywhere near
    inflammable  items.
    Dispose used lamp  units in the same way  as
    fluorescent  lamps. Follow  the  regulations  of your  local
    community  for disposal.
    66
    Maintenance 
    						
    							Resetting the  Lamp  Time
    Resetting  the  lamp  time  from  the menu
    screen
     Press the [MENU]
     button to display
    the  menu
     Select
     “Function” “Lamp Reset”
    from the  menu
    .MENU BACK
    RS-232C
    A
    Back
    Operate
    Select
    Exit
    Function
    Lamp Reset Remote Code
    Communication TerminalOn
    ECO Mode Off
    Off
    Off
    High Altitude Mode
    Network Off Timer Trigger
     On the
     Reset Lamp  Time? screen,
    select  Yes and press the  OK button
    The lamp time is reset to zero.
    .No
    Ye s Reset Lamp Time?
    Resetting
     the  lamp  time  using  the remote
    control
     Insert
     the power plug into the  power
    outlet
     Make sure that you operate the
    remote control
     in the Standby mode
    (the  power plug is inserted into the
    outlet, but the  power is not turned on)
    Press in the order as shown.
    Make sure that you press a button  within two
    seconds  after the last button is pressed.
    Press the last button for at  least two seconds.
    .
    Press for 2 
    seconds or longer
    The “LAMP” indicator and “STANDBY/ON”
    indicator blink alternately  for three seconds.
    After that, the  unit switches to the  Standby
    mode.
    MEMO
    Reset  the lamp  time  only when  you have  replaced  the
    lamp.
    If  the  lamp  time  is reset  while  a lamp  is  in  use,  you may
    lose track of the timing for replacing the  lamp. Doing
    so  may  result  in using  the  lamp  beyond  the estimated
    limit,  thereby  causing lamp  blowout.
    Maintaining the  Cabinet  and  Remote  Control
    Gently wipe off dirt  on the cabinet with a soft cloth.
    If it is extremely  dirty, wet a cloth in water, wring dry  and use it to wipe off the dirt,  followed by wiping again  with a
    dry  cloth.
    Pay  attention to the  following as the cabinet may  deteriorate in condition or the paint may  come off.
    Do not wipe with thinner or benzine
    Do not allow prolonged contact  with rubber or plastic products
    Do not spray volatile  chemicals such as insecticide
    67
    Maintenance 
    						
    							Cleaning and Replacing the Filter
    Clean the filter  regularly Otherwise, the  air intake
    efficiency  may deteriorate, and malfunction may  occur.
    CAUTION
    Make sure that you pull out the power plug from the
    outlet before  cleaning or replacing the filter.
    Before turning  this  unit  upside  down and placing  it on
    the  floor or a table,  make sure that you lay  a soft rag
    in advance to prevent the projector from being
    scratched.
     Remove  the inner filter
    .
    Pull out while 
    pushing down the 
    tab
    
    Clean  the filter
    .
    Wash the filter  with water and dry it in a shaded
    area.
    If the  filter is extremely  dirty, clean it with a
    neutral detergent. Put  on rubber gloves when
    using  a neutral  detergent.
    After washing the  filter with water, make sure
    that it is completely  dry before  reinstalling.
    Otherwise, electric shock  or malfunction may
    occur.
    Do not clean the filter  with a vacuum cleaner or
    air  duster.  The filter  is soft and may  be easily
    damaged.
     Reinstall  the inner filter
    .
    Check that the left 
    and right tabs are 
    locked onto the unit
    If the  filter  is  damaged  or  too  dirty  to  be
    cleaned
    Replace with a new filter. A dirty filter will  dirty the
    internal  parts of  the  unit  and  cause  shadows  to appear
    on the video image.
    To  purchase  a new filter  or when there is dirt in the
    internal parts  of the unit, consult your authorized
    dealer  or nearby service center.
    Inner filter (exchangeable filter)
    Product  no.: PC010661199
    68
    Maintenance 
    						
    							Troubleshooting
    Before sending  the unit to your authorized dealer  for repair, please check the following points.
    The following  symptoms are not malfunctions.
    You  do  not  need  to  worry  about  the  following  symptoms  if  there  is no  abnormality  on the  screen.
    A part of the  top or front surface  of the unit is hot.
    A creaking sound is heard from  the unit
    An operating sound  is heard from the inside of the unit.
    Color smear occurs on some screens
    This  unit  is a digital  device.  This  unit may  become  unable to  operate  normally  due to external  static  or  noise.
    Perform  the  following  operations  when  such malfunctions  occur.
    A If the  unit is in the Standby mode, pull out the  power plug, followed by inserting it again
    B Press the A[STANDBY/ON] button  on the main unit to turn on the power again
    When  “High  Altitude  Mode”  is set  to “On”,  and  “Lamp  Power”  is  set  to “High”  during  3D mode,  the  fan will
    make  louder  noise  than usual  since  it is  designed  to run  at high  speed  in 3D  mode.
    Power  is  not  supplied
    Check ActionRefer to
    Is the  power cord disconnected? Insert  the power cord (plug) firmly. p. 25
    Is the  lamp  cover properly shut? If  the unit is in the Standby  mode, remove the power plug
    and  close  the lamp  cover  properly.  After that, insert  the  plug
    again. p. 66
    Is the  lamp  in the Cool­down mode? After  exiting the  Cool­down  mode, turn on  the  power  again. p. 
     27
    The unit  works  when  power  is turned  on,  but  stops  abruptly  after a few  minutes
    Check ActionRefer to
    Are  the  air inlets and exhaust vent
    blocked? Leave
     proper clearance when installing  the unit p. 14, 15
    p. 19
    Is the  filter dirty? Clean the filter. p. 68
    Video image does  not appear
    Check ActionRefer to
    Is the  correct  external  input selected? Select the  correct external  input terminal. p. 26
    Is  the  power  of the  AV  device  turned  on? Turn on the  power of the AV device  and play the video. p. 22
    Is the  AV device  properly connected? Connect  the AV device  properly. p. 22
    Are  the  correct  signals  being  output  from
    the  AV device? Set
     the  AV device  properly. p.
      22
    Is the  cable in use an  HDMI­certified
    cable? Use an HDMI­certified high­speed
     cable. Also, use as
    short  a cable as  possible. p. 22
    Is “Control with HDMI” set to “On”? If  the video image  does not appear  when “Control with
    HDMI”  is set  to “On”,  change  the setting  to  “Off”  and  power
    on this unit and the external  device again. p. 53
    Is the  video image  temporarily hidden? Press
    
     the  [HIDE]  button p. 26
    69
    Troubleshooting 
    						
    							Remote control  does  not work
    Check ActionRefer to
    Are  the  batteries  correctly loaded? Match the  polarities (ts) correctly  when loading the
    batteries. p. 18
    Are  the  batteries  exhausted? Replace with new batteries. p. 18
    Is there  an obstructing  object between
    the  remote control  and remote sensor? Remove
     any obstructing  object. p. 18
    Is the  remote control  held too far away
    from the  unit? Hold the
     remote control  closer to the sensor during  use.p.
      18
    Are  the  IR (infrared)  3D GLASSES  and
    3D SYNCHRO EMITTER  in use?As 
    there  is  a possibility  of  signal  interference,  when you are
    using  the IR (infrared)  3D GLASSES  together with the 3D
    SYNCHRO EMITTER, try  adjusting the orientation of the
    3D SYNCHRO EMITTER. p. 34
    Unable 
    to view  3D images
    Check ActionRefer to
    Is  the  power  of the  3D  GLASSES  turned
    on? If 
    you  are using  the  PK ­AG2  or PK ­AG33D  GLASSES,  turn
    on the power manually.
    Check  the
    instruction
    manual  of  the  3D
    GLASSES and
    3D SYNCHRO
    EMITTER.
    Are
     the  3D GLASSES charged? Check  the battery  (charge) of the 3D GLASSES.
    Are  the  3D GLASSES and 3D
    SYNCHRO EMITTER  too far away from
    each other? Position
     them at an appropriate distance.
    Is the  correct  3D format  selected? If the  format does not switch  automatically, configure 3D
    Format in the setting menu. p. 
    35
    Color  does  not appear  or  looks  unnatural
    Check ActionRefer to
    Is the  AV device  properly connected? Connect  the AV device  properly. p. 22
    Is the  image  correctly  adjusted? Adjust “Color” and “Tint” accordingly. p. 50
    Is the  color space  of the input signal
    correctly  set? Set
     “Color  Space”  properly. p. 53
    Video image is  fuzzy
    Check ActionRefer to
    Is the  focus  correctly  adjusted? Adjust the  focus. p. 28
    Is  the  unit  placed  too  near  or  too  far away
    from the  screen? Set
     the  unit at  a correct  distance from the screen. p.  77
    Video images  are missing
    Check ActionRefer to
    Has  screen mask been configured? Set “Mask”  to “Off”.p. 54
    Is the  display  position  misaligned? Alter  the “Picture  Position”  value so that the entire  image
    appears  on the screen. p. 54
    70
    Troubleshooting 
    						
    All JVC manuals Comments (0)