Page 31
30 12.16 MENU Auto OFF :’U10’(55H 31H 30H) Definition :Controls the display menu auto-off function Command :’U10’(55H 31H 30H) Parameter type :Special parameter (Refer to 7.3.1 Menu Display Auto OFF Parameter.) Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Communication Examples ◇ When specifying that the menu display is turned off automatically CTLR...
Page 32
31 12.17 Line Display :’U11’(55H 31H 31H) Definition :Sets the line source (area) display after changing input terminals Command :’U11’(55H 31H 31H) Parameter type :ON/OFF Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Communication Examples ◇ When setting the line display to OFF CTLR ‘!’ ‘1’ SP ‘U11’ SP ‘0’ CR DLA...
Page 33
32 12.18 Sleep Time :’U12’(55H 31H 32H) Definition :Sets the sleep time Command :’U12’(55H 31H 32H) Parameter type :(*) Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X The Sleep time function automatically turns off the projector power if the no-signal status continues for a specified time. *Available parameters Sleep time can be set to any of the following:...
Page 34
33 12.19 Right/Left Reverse :’U17’(55H 31H 37H) Definition :Reverses the image horizontally Command :’U17’(55H 31H 37H) Parameter type :ON/OFF Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Communication Examples ◇ When reversing the image horizontally (Right /Left reverse) CTLR ‘!’ ‘1’ SP ‘U17’ SP ‘1’ CR DLA...
Page 35
34 12.20 Top/Bottom Invert :’U18’(55H 31H 38H) Definition :Inverts the image vertically Command :’U18’(55H 31H 38H) Parameter type :ON/OFF Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Communication Examples ◇ When inverting the image vertically (Top/Bottom invert) CTLR ‘!’ ‘1’ SP ‘U18’ SP ‘1’ CR DLA ‘@’ ‘1’...
Page 36
35 12.21 Decoder :’U19’(55H 31H 39H) Definition :Selects the color TV broadcast system Command :’U19’(55H 31H 39H) Parameter type :Special parameter (Refer to 7.3.3 Decoder Parameter.) Reply time :3seconds Conditions :Except when there is no Source (Area) signal Operation mode Standby mode Power ON mode Cool-down mode Emergency mode X O X X # Communication Examples ◇ When selecting NTSC as the broadcast system CTLR ‘!’ ‘1’...
Page 37
36 12.22 Input Select :’U1A’(55H 31H 41H) Definition :Selects the video input terminals Command :’U1A’(55H 31H 41H) Parameter type :Special parameter (Refer to 7.3.5 Input Select Parameter.) Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode X O X X # Communication Examples ◇ When selecting D-SUB as the video input CTLR ‘!’ ‘1’ SP ‘U1A’ SP ‘3’ CR DLA...
Page 38
37 12.23 Transfer Rate :’U1B’(55H 31H 42H) Definition :Controls the transfer rate for RS-232C Command :’U1B’(55H 31H 42H) Parameter type :Special parameter(Refer to 7.3.2 Transfer Rate Parameter.) Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X * After this command has been received and processed correctly, the Tally (Response) Data is returned at the new transfer rate....
Page 39
38 12.24 Lamp Time :’U1C’(55H 31H 43H) Definition :Reset/check the lamp operation Command :’U1C’(55H 31H 43H) Parameter type :(*) Reply time :3seconds Conditions : Operation mode △ When resetting Standby mode Power ON mode Cool-down mode Emergency mode O X X X △ When requesting current time Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Data Format △ Reset data format ‘!’...
Page 40
39 (*)Parameter2 Parameter 2 shows whether the lamp replacement time is close or not, based on the following calculation: (Lamp service life-100 hours )≦ Lamp operating time < Lamp service life Character HEX Lamp replacement time not close ‘0’ 30H Lamp replacement time close ‘1’ 31H Lamp life exceeded ‘2’ 32H # Communication Examples ◇ When requesting the current lamp operating time (if the lamp operating time is 150 hours)...