30 12.16 MENU Auto OFF :’U10’(55H 31H 30H) Definition :Controls the display menu auto-off function Command :’U10’(55H 31H 30H) Parameter type :Special parameter (Refer to 7.3.1 Menu Display Auto OFF Parameter.) Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Communication Examples ◇ When specifying that the menu display is turned off automatically CTLR ‘!’ ‘1’ SP ‘U10’ SP ‘1’ CR DLA ‘@’ ‘1’ SP ‘0’ CR ◇ When requesting the current menu display auto-off setting (if menu display does not turn off automatically) CTLR ‘?’ ‘1’ SP ‘U10’ CR DLA ‘@’ ‘1’ SP ‘0’ SP ‘0’ CR
31 12.17 Line Display :’U11’(55H 31H 31H) Definition :Sets the line source (area) display after changing input terminals Command :’U11’(55H 31H 31H) Parameter type :ON/OFF Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Communication Examples ◇ When setting the line display to OFF CTLR ‘!’ ‘1’ SP ‘U11’ SP ‘0’ CR DLA ‘@’ ‘1’ SP ‘0’ CR ◇ When requesting the current line display setting (if the line display is set to ON) CTLR ‘?’ ‘1’ SP ‘U11’ CR DLA ‘@’ ‘1’ SP ‘0’ SP ‘1’ CR
32 12.18 Sleep Time :’U12’(55H 31H 32H) Definition :Sets the sleep time Command :’U12’(55H 31H 32H) Parameter type :(*) Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X The Sleep time function automatically turns off the projector power if the no-signal status continues for a specified time. *Available parameters Sleep time can be set to any of the following: 15 min., 30 min., 60 min., and 0 min. When the above times are represented as numerical parameters: Character HEX 15min. ‘000F’ 30H 30H 30H 46H 30min. ‘001E’ 30H 30H 31H 45H 60min. ‘003C’ 30H 30H 33H 43H 0min. ‘0000’ 30H 30H 30H 30H The sleep time function is disabled when the time is set to “0 min”. #Tally (Response) data format to current sleep time query ‘ @’ ‘1’ SP Normal Termination Status SP Parameter 1 SP Parameter 2 CR Parameter 1:Indicates the sleep time specified (Refer to Available parameters) Parameter 2 :Indicates the remaining sleep time. Parameter type is numeric. # Communication Examples ◇ When specifying 30 min. as the sleep time CTLR ‘!’ ‘1’ SP ‘U12’ SP ‘001E’ CR DLA ‘@’ ‘1’ SP ‘0’ CR ◇ When requesting the current sleep time setting (if the sleep time is set to 15 min. and the remaining time is 3 min.) CTLR ‘?’ ‘1’ SP ‘U12’ CR DLA ‘@’ ‘1’ SP ‘0’ SP ‘000F’ SP ‘0003’ CR
33 12.19 Right/Left Reverse :’U17’(55H 31H 37H) Definition :Reverses the image horizontally Command :’U17’(55H 31H 37H) Parameter type :ON/OFF Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Communication Examples ◇ When reversing the image horizontally (Right /Left reverse) CTLR ‘!’ ‘1’ SP ‘U17’ SP ‘1’ CR DLA ‘@’ ‘1’ SP ‘0’ CR ◇ When requesting the current R/L reverse setting (if the image is not reversed horizontally) CTLR ‘?’ ‘1’ SP ‘U17’ CR DLA ‘@’ ‘1’ SP ‘0’ SP ‘0’ CR
34 12.20 Top/Bottom Invert :’U18’(55H 31H 38H) Definition :Inverts the image vertically Command :’U18’(55H 31H 38H) Parameter type :ON/OFF Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Communication Examples ◇ When inverting the image vertically (Top/Bottom invert) CTLR ‘!’ ‘1’ SP ‘U18’ SP ‘1’ CR DLA ‘@’ ‘1’ SP ‘0’ CR ◇ When requesting the current Top/Bottom invert setting (if the image is not inverted vertically) CTLR ‘?’ ‘1’ SP ‘U18’ CR DLA ‘@’ ‘1’ SP ‘0’ SP ‘0’ CR
35 12.21 Decoder :’U19’(55H 31H 39H) Definition :Selects the color TV broadcast system Command :’U19’(55H 31H 39H) Parameter type :Special parameter (Refer to 7.3.3 Decoder Parameter.) Reply time :3seconds Conditions :Except when there is no Source (Area) signal Operation mode Standby mode Power ON mode Cool-down mode Emergency mode X O X X # Communication Examples ◇ When selecting NTSC as the broadcast system CTLR ‘!’ ‘1’ SP ‘U19’ SP ‘0’ CR DLA ‘@’ ‘1’ SP ‘0’ CR ◇ When requesting the current broadcast system setting (if the broadcast system is set to PAL) CTLR ‘?’ ‘1’ SP ‘U19’ CR DLA ‘@’ ‘1’ SP ‘0’ SP ‘2’ CR
36 12.22 Input Select :’U1A’(55H 31H 41H) Definition :Selects the video input terminals Command :’U1A’(55H 31H 41H) Parameter type :Special parameter (Refer to 7.3.5 Input Select Parameter.) Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode X O X X # Communication Examples ◇ When selecting D-SUB as the video input CTLR ‘!’ ‘1’ SP ‘U1A’ SP ‘3’ CR DLA ‘@’ ‘1’ SP ‘0’ CR ◇ When requesting the current video input setting (if the video input is selected) CTLR ‘?’ ‘1’ SP ‘U1A’ CR DLA ‘@’ ‘1’ SP ‘0’ SP ‘1’ CR
37 12.23 Transfer Rate :’U1B’(55H 31H 42H) Definition :Controls the transfer rate for RS-232C Command :’U1B’(55H 31H 42H) Parameter type :Special parameter(Refer to 7.3.2 Transfer Rate Parameter.) Reply time :3seconds Conditions : Operation mode Standby mode Power ON mode Cool-down mode Emergency mode O O O X * After this command has been received and processed correctly, the Tally (Response) Data is returned at the new transfer rate. # Communication Examples ◇ When changing the transfer rate to 9600 bps from the current setting of 19200 bps CTLR ‘!’ ‘1’ SP ‘U1B’ SP ‘0’ CR DLA ‘@’ ‘1’ SP ‘0’ CR 19200bps until this point 9600bps from here on * The default transfer rate setting is 19200bps.
38 12.24 Lamp Time :’U1C’(55H 31H 43H) Definition :Reset/check the lamp operation Command :’U1C’(55H 31H 43H) Parameter type :(*) Reply time :3seconds Conditions : Operation mode △ When resetting Standby mode Power ON mode Cool-down mode Emergency mode O X X X △ When requesting current time Standby mode Power ON mode Cool-down mode Emergency mode O O O X # Data Format △ Reset data format ‘!’ ‘1’ SP ‘U1C’ SP Reset Parameter CR (*)Reset parameter Character HEX ‘[()]’ 5BH 28H 29H 5DH * Never issue the Reset command unless the lamp has been replaced with a new one. △ Tally (Response) data format when requesting current time ‘@’ ‘1’ SP Normal Termination Status SP Parameter 1 SP Parameter 2 CR (*)Parameter1 The Projector has an incremental counter which counts Lamp Operation Time at 1 time in every 4 minutes. Parameter 1 shows this counter value. The parameter type is numeric. Actual lamp operating time is obtained by converting the Parameter 1 value into signed 2-byte binary hexadecimal and dividing it by 15.
39 (*)Parameter2 Parameter 2 shows whether the lamp replacement time is close or not, based on the following calculation: (Lamp service life-100 hours )≦ Lamp operating time < Lamp service life Character HEX Lamp replacement time not close ‘0’ 30H Lamp replacement time close ‘1’ 31H Lamp life exceeded ‘2’ 32H # Communication Examples ◇ When requesting the current lamp operating time (if the lamp operating time is 150 hours) CTLR ‘?’ ‘1’ SP ‘U1C’ CR DLA ‘@’ ‘1’ SP ‘0’ SP ‘08CA’ SP ‘0’ CR