InFocus Projector IN5316HDa User Manual
Have a look at the manual InFocus Projector IN5316HDa User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 493 InFocus manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
— 54 — Timing Mode Table The projector can display multiple resolutions. The following table outlines the resolutions that can be displayed by the projector. SIGNAL RESOLUTION H-SYNC (KHZ) V-SYNC (HZ) COMPOSITE / S-VIDEO VGA 1/2 /RGBHV (ANALOG) HDMI (DIGITAL) DP (DIGITAL) NTSC — 15.734 60.0 O — — — PAL/SECAM — 15.625 50.0 O — — — VESA 720 x 400 37.9 85.0 — O O O 640 x 480 31.5 60.0 — O O O 640 x 480 37.9 72.8 — O O O 640 x 480 37.5 75.0 — O O O 640 x 480 43.3 85.0 — O O O 800 x 600 35.2 56.3 — O O O 800 x 600 37.9 60.3 — O O O 800 x 600 46.9 75.0 — O O O 800 x 600 48.1 72.2 — O O O 800 x 600 53.7 85.1 — O O O 1024 x 768 48.4 60.0 — O O O 1024 x 768 56.5 70.1 — O O O 1024 x 768 60.0 75.0 — O O O 1024 x 768 68.7 85.0 — O O O 1280 x 800 49.7 59.8 — O O O 1280 x 800 62.8 74.9 — O O O 1280 x 800 71.6 84.8 — O O O 1280 x 1024 64.0 60.0 — O O O 1280 x 1024 80.0 75.0 — O O O 1280 x 1024 91.1 85.0 — O O O 1400 x 1050 65.3 60.0 — O O O 1440 x 900 55.9 60.0 — O O O 1600 x1200 75.0 60 — O O O 1920 x1080 67.2 60 — O O O 1920 x1200[RB] 74.0 60 — O O O Apple Macintosh 640 x 480 35.0 66.7 — O O O 832 x 624 49.7 74.5 — O O O 1024 x 768 60.2 74.9 — O O O 1152 x 870 68.7 75.1 — O O O SDTV 480i 15.734 60.0 — O O O 576i 15.625 50.0 — O O O EDTV 576p 31.3 50.0 — O O O 480p 31.5 60.0 — O O O
– 55 – SIGNAL RESOLUTION H-SYNC (KHZ) V-SYNC (HZ) COMPOSITE / S-VIDEO VGA 1/2 /RGBHV (ANALOG) HDMI (DIGITAL) DP (DIGITAL) HDTV 720p 37.5 50.0 — O O O 720p 45.0 60.0 — O O O 1080i 33.8 60.0 — O O O 1080i 28.1 50.0 — O O O 1080p 27 24.0 — O O O 1080p 28.13 25.0 — O O O 1080p 33.75 30.0 — O O O 1080p 67.5 60.0 — O O O 1080p 56.3 50.0 — O O O O: Frequency supported —: Frequency not supported (*) VGA supports EDTV/SDTV/HDTV component with an adapter.
– 57 – REGULATORY COMPLIANCE FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. Changes or modifications not expressly approved by the parties responsible for compliance could void the user’s authority to operate the equipment. Canada This class B digital apparatus complies with Canadian ICES-003. WEEE NOTE: This product is covered electrical and electronic equipment under the European Union’s Waste from Electrical and electronic Equipment (“WEEE”) Directive (2002/96/EC). The WEEE Directive requires that covered equipment be collected and managed separately from typical household waste in all EU member states. Please follow the guidance of your local environmental authority or ask the shop where you purchased the product for collection or recycling options. Safety Certifications FCC, UL, CUL, CB/CE, KC, CCC, EAC, PSB, NOM., CECP/ECO, SASO TUV-safety, UL-S(Argentina), C-Tick/RCM
— 58 — APPENDIX I Serial Communication The following table describes the serial communication configuration that should be used when interfacing to CLI via the serial port. Windows HyperTerminal or ProComm are two tools that can be used to send CLI commands across the serial port. Setting Value Bits per second 19200 Data bits 8 Parity None Stop bits 1 Flow control None Emulation VT100 No Function Command RW Min Max Default Step Parameter 1 AC Power On (Auto power on) APO RW 0 1 0 1 0:Disable; 1:Enable 2 Aspect Ratio ARZ RW 0 5 0 1 0:Fill 1:4:3 2:16:9 3:Letterbox 4:Native 5:2.35:1 3 Auto Image AIM W n/a 1 1 1 1: Enable 4 Auto Off Time No signal power off AOT RW 0 36 6 1 0:Never 1:5 minutes 2:10 minutes 3:15 minutes … 35:175 minutes 36:180 minutes 5 Auto Source ASC RW 0 1 1 1 0:Disable; 1:Enable 6 Blank Screen BLK RW 0 1 0 1 0:Disable; 1 Enable 7 Brightness BRT RW 0 100 50 1 Display Mode=User1 only 8 Ceiling (Projection mode) CEL RW 0 3 0 1 0:Front 1:Rear 2:Ceiling 3:Ceiling+Rear 9 Closed Captions: Non- Muted CLC RW 0 1 0 1 Off On (CC1) 10 Color CLR RW 0 100 50 1 Video SVideo only 11 Color Temp TMP RW 0 2 Source Specific 1 Display Mode=User only 0:Warm 1:Normal 2:Cold 12 Contrast CON RW 0 100 50 1 Display Mode=User1 only
– 59 – No Function Command RW Min Max Default Step Parameter 13 Current Source SRC RW 0 20 0 1 0 = Computer1 1 = Computer 2 3 = RGBHV 4 = HDMI1 7 = DisplayPort1 9 = Component1 11 = Composite 12 = S-Video 20 = DVI 14 Digital Zoom DZM RW -10 10 0 1 Digital Zoom 15 Error Condition ERR R 0 9 0 1 0:No error 1:Lamp not lit after 5 Attempts 3:Lamp went out unexpectedly 4:Fan failure 5:Over-temperature 8:DMD error 9:Color wheel 16 Factory Reset RST W n/a 1 1 1 1:reset 17 Freeze Screen FRZ RW 0 1 0 1 0:Disable; 1:Enable 18 Gamma GTB RW 0 5 Source Specific 1 Display Mode=User1 only 0:1.8 1:2.0 2:2.2 3:2.4 4:B&W 5:Linear 19 Horz. Position HPS RW -5 5 Source Specific 1 RGB source only (HPS?) to get range 20 Vert. Position VPS RW -5 5 source Specific 1 RGB source only (VPS?) to get range (VPS+) (VPS-) 21 Current Lamp Hours in Boost mode (370W) LMO R 0 9999 0 1 Displays the total lamp hours the current lamp has operated in Boost mode. 22 Current Lamp Hours in Normal mode (330W) LME R 0 9999 0 1 Displays the total lamp hours the current lamp has operated in Normal mode. 23 Current Lamp Hours in Eco mode (280W) LML R 0 9999 0 1 Displays the total lamp hours the current lamp has operated in Eco mode. 24 Current Lamp Hours (All modes) LMP R 0 9999 0 1 Displays the total lamp hours the current lamp has operated in all modes. 25 Reset Lamp Hours LRT W n/a 1 1 1 Resets the lamp counter (all modes) to zero. 26 Lamp hours reset counter LMR R 0 9999 0 1 Displays the number of times the lamp counter has been reset
— 60 — No Function Command RW Min Max Default Step Parameter 27 Total Projection Hours (lamp1+lamp2+…) LMT R 0 9999 0 1 Displays the total number of hours the projector has been in operation (all lamps). 28 Lamp Life LIF R n/a 1500 1500 n/a Lamp life 1500 29 Lamp Power Select High power (Boost) / Low power (Normal) / Eco power (Eco) IPM RW 0 2 1 1 This Read/Write command sets the lamp mode 0 = Eco 1 = Normal 2 = Boost 33 Language LAN RW 0 26 0 1 0:English 1:French 2:German 3:Spanish 4:Portuguese 5:Simplified Chinese 6:Traditional Chinese 7:Italian 8:Norwegian 9:Swedish 10:Dutch 11:Russian 12:Polish 13:Finnish 14:Greek 15:Korean 16:Hungarian 17:Czech 18:Arabic 19:Turkish 20:Vietnamese 21:Japanese 22:Thai 23:Farsi 24:Hebrew 25:Bahasa 26:Danish 34 Menu MNU RW 0 1 0 1 0:Clear; 1:Display 35 Menu Navigation NAV W 0 5 n/a 1 0:Menu Key 1:Up Key 2:Down Key 3:Select Key 4:Left Key 5:Right Key 36 Menu Transparency TOE RW 0 4 0 5 0:0% 1:25% 2:50% 3:75% 4:100% 37 Mute MTE RW 0 1 0 1 0:Disable; 1:Enable 38 Overscan OVS RW 0 1 0 1 0:Disable; 1:Enable 39 Phase(Frequency) MSS RW 0 31 source Specific 1 RGB source only 40 Power PWR RW 0 1 0 1 0:Turn Off 1:Turn On
– 61 – No Function Command RW Min Max Default Step Parameter 41 Presets PST RW 0 8 source Specific 1 Display mode 0:Presentation 1:Bright 2:Game 3:Movie 4:TV 5:sRGB 6:Blackboard 7:User1 8:User2 42 Projector Firmware Ver. FVS R string LX737-692IF-DPEXX 43 Projector Info menu PRI W 1 1 1:Display Status Menu 44 Projector Model MDL R string XGA: IN5312a 1080P: IN5316HDa 45 Projector Resolution NRS R string XGA 46 Search Screen DSU RW 0 4 0 1 0:Blue 1:Black 2:White 3:Red 4:Green 47 Sharpness SHP RW 0 31 16 1 Display mode User 1 only same as OSD range 48 System State SYS R 0 18 0 1 0:Standby 2:Start Up 12:Cooling 18:Error 49 Tint TNT RW 0 100 50 1 Tint 50 Tracking MTS RW -5 5 0 1 RGB source only 51 Vert. Keystone DKV RW -40 40 0 1 Vertical keystone 52 Volume VOL RW 0 10 5 1 Volume