Page 71
60 11 FREQUENCY TABLE New2001 11 Other communications— other countries CH Frequency 1 446.00625 2 446.01875 3 446.03125 4 446.04375 5 446.05625 6 446.06875 7 446.08125 8 446.09375D D PMR446 channels (unit: MHz) CH Frequency 59 434.525 60 434.550 61 434.575 62 434.600 63 434.625 64 434.650 65 434.675 66 434.700 67 434.725 68 434.750 69 434.775 CH Frequency 1 433.075 2 433.100 3 433.125 4 433.150 5 433.175 6 433.200 7 433.225 8 433.250 9 433.275 10 433.300 11 433.325 12 433.350 13 433.375 14 433.400 15...
Page 72
61 11 FREQUENCY TABLE New2001 CH Frequency 1 476.425 MHz 2 476.450 MHz 3 476.475 MHz 4 476.500 MHz 5 476.525 MHz 6 476.550 MHz 7 476.575 MHz 8 476.600 MHz 9 476.625 MHz 10 476.650 MHz 11 476.675 MHz 12 476.700 MHz 13 476.725 MHz 14 476.750 MHz 15 476.775 MHz 16 476.800 MHz 17 476.825 MHz 18 476.850 MHz 19 476.875 MHz 20 476.900 MHzD D UHF C.R.S (Citizen Radio Service) channels CH Frequency 21 476.925 MHz 22 476.950 MHz 23 476.975 MHz 24 477.000 MHz 25 477.025 MHz 26 477.050 MHz 27 477.075 MHz 28...
Page 73
62 12 MAINTENANCE 1112 PROBLEM POSSIBLE CAUSE SOLUTION REF. Troubleshooting If your receiver seems to be malfunctioning, please check the following points before sending it to a service center. No power comes on. No sound comes from the speaker. Sensitivity is low and only strong signals are audible. Frequency cannot be set. No beep sound. Receive audio is distorted. Desired set mode item cannot be selected. Programmed scan does not start. Memory or bank scan does not start. Installed batteries cannot...
Page 74
63 12 MAINTENANCE New2001 CP-18A/E fuse replacementIf the fuse blows or the receiver stops functioning while oper- ating with the optional CP-18A/E, find the source of the prob- lem if possible, and replace the damaged fuse with a new, rated one (FGB 5 A) as shown below. Fuse 5 A IC-R5_1.qxd 02.10.23 11:29 Page 63 (1,1)
Page 75
64 13 SPECIFICATIONS 1213 D D GENERAL•Frequency coverage : (Unit: MHz) USA 0.150–823.995, 849.000–868.995, 894.000–1309.995 France 0.150–29.995, 50.200–51.200, 87.500–108.000, 144.000–146.000, 430.000–440.000, 1240.000–1300.000 Other than above 0.150–1309.995 MHz •Number of memory channels : 1250 (incl. 50 scan edges and 200 auto write channels) •Frequency resolution : 5, 6.25, 8.33,* 9*, 10, 12.5, 15, 20, 25, 30, 50, 100 kHz *selectable depending on the operating frequency band. •Operating temperature...
Page 76
65 OPTIONS New2001 New2001 14OptionsBC-149 A/D AC ADAPTER Regularly charges the installed batteries. 6 V DC/1 A output. CP-18A/E CIGARETTE LIGHTER CABLE WITH DC -DC CONVERTER Allows you to operate the re- ceiver through a 12 V cigarette lighter socket, and also charges the installed rechargeable bat- teries regularly. A DC-DC con- verter is built-in. AD-92SMA ANTENNA CONNECTOR ADAPTER Allows you to connect an exter- nal antenna with a BNC con- nector. SP-13 EARPHONE Provides clear receive audio in...
Page 77
New2001 q w iR5 VFO and memory mode selection POCKET GUIDE Push [V/M•S.MW•~] to toggle between VFO and memory mode.➥ Receive mode selection Push [MODE•SCAN] several times to select the desired mode➥ Audio level setting Push [Y] to increase, push [Z] to decrease the audio level. ➥ Squelch level setting While pushing [SQL], rotate [DIAL] to set the squelch level. ➥ Frequency band selection Push [BAND• ] several times, or while pushing [BAND• ], rotate [DIAL] to select the...
Page 78
New2001 q w e r Memory channel programming Set the desired frequency and other functions in VFO mode. Push [V/M•S.MW•~] for 1 sec. to enter select memory write condition. • 1 short and 1 long beeps sound.Rotate [DIAL] to select the desired memory channel number. Push [V/M•S.MW•~] for 1 sec. again to program the contents into the selected channel. • 3 beeps sound. q w e Scan skip setting Push [V/M•S.MW•~] to select memory mode. Rotate [DIAL] to select the desired memory channel. While pushing...
Page 79
DECLARATION OF CONFORMITY 68 16 CE 16 New2001 We Icom Inc. Japan 1-1-32, Kamiminami, Hirano-ku Osaka 547-0003, Japan Declare on our sole responsibility that this equipment complies with the essential requirements of the Radio and Telecommunications Terminal Equipment Directive, 1999/5/EC, and that any applicable Essential Test Suite measurements have been performed.Kind of equipment: COMMUNICATIONS RECEIVERType-designation: iR5 Version (where applicable): This compliance is based on conformity with the...
Page 80
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan A-6198H-1EX-q Printed in Japan©2002 Icom Inc. New2001 IC-R5_1.qxd 02.10.23 11:29 Page 69 (1,1)