Home > Husqvarna > Sewing Machine > Husqvarna Designer 1 Service Manual

Husqvarna Designer 1 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Husqvarna Designer 1 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Husqvarna manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							              21 104 72 47-26
    Adjustment
    Get into the service program of the machine.
    The needle should be in its highest position.
    Touch Needle - 
    , row 1.
    Loosen screw (E) in the cog wheel (D) on the step motor shaft.
    Turn the cog wheel until the needle is in the centre of
    the presser foot.
    Touch Needle - 
    , row 1 .
    Loosen screw (F) in the calibration stop (G) and
    turn it until the gap is correct  (0mm).
    Note! The position of the eccentric.
    Touch Needle - 
    , row 1 .
    Turn the screw (H) until the gap is correct (0 mm).
    This setting is only a sideways limitation.
    Touch Needle -
     , row 1
    The needle should now take its centre position into the needle
    hole of the presser foot.
    Settings 
    						
    							22104 72 47-26
    21
    7.  Setting of the needle in relation to the presser foot
    Check
     Insert a new needle 90 in the machine.
    When the machine is set at straight stitching centre position, the needle bar shall be set in
     such a way that a needle 90 passes through the centre of the needle hole in
    the presser foot.
     1 = seen from the front
     2 = seen from the side
    Adjustment
    1. Turn on the main switch
    Keep the machine set at straight stitching centre position
     (alt. service menu 1, touch Needle- 
    , row1 ).
    2. Loosen  the two screws (A) and (B).
       Move  the needle bar with the two eccentric screws (C)  or (D) until
       the requirement is obtained.
    - The lenght movement is adjusted by moving the eccentric screw (C)
    - The side movement is adjusted by moving the eccentric screw (D)
    3. Tighten the screws (A) and (B).
    4. Check the setting by turning the main switch on and off a couple of times.
    NOTE! The Setting of the needle in relation to the presser foot affects the function
       of 6. Basic setting - the step motor of the needle.
    Needle point
    Settings 
    						
    							              23 104 72 47-26
    8. The gap between the needle and the hook
    Check
    1. Set the machine on straight stitching.
    2. Insert a new needle 90 in the machine.
    3. Rotate hand wheel until the tip of the hook arrives behind the needle.
    Check the gap by pressing a small screw driver against the needle.
    The gap should be as small as possible, but max 0.15 mm.
    Adjustment
    If the gap is too large:
    1. Loosen the screw (A).
    2. Turn screw (B) clockwise until the needle
        touches the tip of the hook
    3. Turn screw (A) until the gap is correct
    If the gap is too small:
    1. Loosen the screw (B)
    2. Turn screw (A) to make the gap larger
        and then loosen the screw (A).
    3. Turn screw (B) clockwise until the needle
        touches the tip of the hook
    4. Turn screw (A) until the gap is correct
    NOTE! Always tighten screw (A).
    Check!
    Settings 
    						
    							24104 72 47-26
    9. The timing of the hook in relation to the needle
    Check
    - Set a new needle 90 into the machine
    - Dismount the stitch plate, bobbin case holder and the bobbin case.
    - Set machine on straight stitching.
    - As the needle is moving upwards, the tip of the hook should pass
       behind the centre of the needle, when the needle is 2.5 mm above
       its lower turning position.
    NOTE! Before any adjustment is done check that the setting
     2. Setting the hook in relation to the feeding eccentric is correct (see page 17).
    Check with setting gauge 411 17 52-01.
    1. Turn the handwheel until the needle is at its lower turning position.
    2. Place the setting gauge on the needle bar so that the springloaded
         stud (A) just touches the needle bar frame and tighten the screw.
    3. Move the needle upwards with the handwheel until the springloaded
        stud (A) rests against its stop in the setting gauge.
    4. The tip of the hook should now be behind the centre line of the needle.
    Adjustment
    1. Remove the blank pointed screw (B) and loosen the other 2 screws
        in the belt wheel of the arm shaft.
    2. Repeat checking points 1, 2 and 3 with setting gauge 411 17 52-01 .
    3. Hold the arm shaft and turn the hook until its tip arrives behind
        the centre line of the needle.
    4. Tighten one of the black screws.
    5. Make sure the screw descends into the groove of the shaft so that the
        belt wheel is placed correctly sideways.
    6. Check.
    7. Tighten all the screws.
    Settings 
    						
    							              25 104 72 47-26
    10. The needle height
    Check
    1. Bring the needle into its lower turning position.
    2. The gap between the upper end of the needle and the surface (B)
         of the hook ring should be 29.15 ± 0.2 mm.
    The check is executed with a polished needle 90 which is 29.15 mm long.
    Order nr. 412 35 29 - 01
    Adjustment
    1. Bring the needle to its lower turning position.
    2. Loosen screw (A) and move the needle bar until the correct
        measure is obtained.
    3. Tighten the screw.
    NOTE! Check by means of a twin needle that the needle bar is not
       twisted. May cause jump stitches when sewing with a twin needle.
    Settings 
    						
    							26104 72 47-26
    13 mm
    11.   Presser foot parallelism to the feed dog
    Check
    The presser foot (A)  should be parallel to the feed dog (B) .
    Adjustment
    1. Loosen screw (C) and turn the presser foot until
        it is parallel to the feed dog.
    2. Tighten the screw (C).
    12.Presser foot height to the stitch plate
    Check
    When the pressar foot is in its highest lifting position it shall be
    approx. 13 mm above the stitch plate.
    Adjustment
    1. Get into the service program
    2. Touch Servo -
    , row 3.
    The pressar bar now takes its highest lifting position.
    3. Loosen screw (C) and move the presser bar until
        the pressar foot is approx. 13 mm above the stitch plate.
    4. Tighten the screw (C).
    Note! This setting affects:
     11.   Presser foot  parallelism  to the feed dog
    Settings 
    						
    							              27 104 72 47-26
    13. Setting the stitch plate (the hook cover) in relation to the
        needle in the feeding direction.
    Check
    1.  Insert a new needle 90 in the machine.
    2. In the feeding direction the needle should descend right into the
    middle of the needle hole of the stitch plate.
    14. The sideways setting of the stitch plate (the hook cover) in
        relation to the presserfoot.
    Check
    The presser foot (A) should be centred and parallel to the feed dog groove (B).
    Adjustment
       Loosen the 4 screws of the hook cover and move it so that:
       - the needle in feeding direction decends in the middle of the stitch plate.
       - the presser foot is centered and parallel to the feed dog groove .
    Settings 
    						
    							28104 72 47-26
    A C B
    0,5 mm
    Fig 1
    15. The height of the hook
    Is checked between the bobbin case and the case holder
    Check
    The distance between the bobbin case and the case holder  should
    be 0.5 
    + 0.1
    -0,05 mm.
    The check is carried out at the tightest spot between the bobbin case and the case
    holder. Check at the two marked positions according to fig. 1.
    Adjustment
    1. Loosen screw (A).
    2. The gap between the hook and its cover can now be adjusted by turning the stud (C)
        right or left.
    - To the right, the gap becomes larger.
    - To the left, the gap becomes smaller..
    3. When the adjustment is done. Remove stitch plate, bobbin case holder and bobbin case.
    4. Push the hook shaft (B)downwards and tighten the screw (A).
    5. Re-check.
    Note! This  setting  affects: 1.   The play of the hook gear.
    9. The timing of the hook and the needle
    10. The needle height
    Check with distance gauge 412 38 85-01.
    Settings 
    						
    							              29 104 72 47-26
    16.Pre-setting of the step motor for the side feeding
    Check
    1.Dismount the circuit board.
    2. Dismount the side feeding unit.
    3. Mount the circuit board.
    4.Connect the side feeding unit. Hold the side feeding unit in your hand.
    5.Touch Side-M - 
     ,row 2. Turn the handwheel in such a way that the cog
    segment changes between its 2 positions.
      Touch Side-M - 
     ,row 2. Turn the handwheel in such a way that the
    step motor changes between its 2 positions.
    The distance between the pins (A) and the side of the segment shall be equally large
    in both positions.
    Note ! The movement of the segment is different from left position to the right position.
    Adjustment
    1. Loosen screw (B).
    2. Adjust the cog segment in such way that the distance (A) between the pins and the side
    of the segment is equally large in both positions.
    NOTE! The adjustment must  be done in  both Side-M - 
     and Side-M -  postitions.
    3.Tighten screw (B).
    4. Re-check .
    Settings 
    						
    							30104 72 47-26
    17.Setting the feeding mechanism sideways
    Check
    1. Get into the service program
    2. Touch Side-M 
    ,row 2. Turn the handwheel in such a way that the step motor
        changes between its 2 positions. The feed dog should not at any point touch the
    stitchplate.
    3. Touch Side-M
    ,row 2. Turn the handwheel in such a way that the step motor
        changes between its 2 positions. The feed dog should not at any point touch the
    stitchplate.
    Adjusment
    1. Loosen the 3 screws (A), located behind the circuit board .
    2. Move the feeding device sideways until a correct position of the feed dog is
        accomplished by turning adjustment screw (B),located behind the circuit board .
    3. Tighten the 3 screws (A).
    4. Re-check the positions of the feed dog.
    Settings 
    						
    All Husqvarna manuals Comments (0)

    Related Manuals for Husqvarna Designer 1 Service Manual