1 Boot from SAN Thischapterdescribesbootsetupproceduresfromastorageareanetwork(SAN)withtherequired softwareandhardwareusingHPEmulexHBAsorHPQLogicHBAsrunningonItaniumorProliant Windowssystems.Forthelatestversionofthisdocument,seetheHPstoragewebsite: http://h18006.www1.hp.com/storage/networking/index.html Traditionally,HPserversbootoperatingsystemsfrominternalSCSIorIDEstoragedevices.Withthe supportofexternalbootingfromHPStorageWorksHBAsandRAIDarrays,youhavetheoptionto eliminateserver-basedinternalbootdevices.Bootingfromanexternaldevicedecreasesdowntime throughfasterserverreplacementintheeventofaserverorHBAfailure. IMPORTANT: For important troubleshooting information, see 3 Troubleshooting. BFS Rules and Assumptions Makesurethatthefollowingrulesandassumptionsaremetbeforeyoubegin. •AllrulesandassumptionsintheAboutthisguidechapter,aswellasthischapter,havebeensat- isfied. •OneavailablepathfromHBAtostorageLUN. •Inadditiontothisguide,seethefollowingdocumentation: •ReleasenotesforHPStorageWorksEmulexhostbusadaptersforWindows. •ReleasenotesforHPStorageWorksQLogichostbusadaptersforWindows. •Whitepapersandbest-practicesdocuments. ToinstallWindowsonaBootfromSANLUNwithdriverversionsthatarenotsupportedbytheinitial operatingsystemrelease,thenewdrivermustbeintegratedaspartoftheinstallationprocessusing aBFSkit. Why boot from SAN? BootingfromSANprovides: •Improveddisasterrecovery •ReducedbackuptimewhenthebootpathisthroughaSAN •AdditionalSAN-managedfeatures FibreChannelhostbusadapterssoftwareguideforWindows11
Required hardware and software ThefollowingtableliststhehardwareandsoftwarerequiredtobootfromaSAN. Table 3 Required hardware and software RequirementSupported feature DatacenterEnterpriseandStandardeditionsof: •WindowsServer2003forItanium-basedsystems. •WindowsServer2003withSP1forItanium-basedsystems. •WindowsServer2003x86/x64. •WindowsServer2008x86/x64 NOTE: All operating systems requires the latest supported Microsoft Service Pack. Operatingsystems EVA MSA XP RAIDarrays AllHPsupportedFibreChannelswitches,runningthelatestreleasedswitchfirmware aresupportedinaBootFromSANconfiguration.Formoreinformation,seethewebsite http://h18006.www1.hp.com/storage/networking/index.html FibreChannel switches AllHPProLiantservers,includingHPProLiantbladeservers,aresupportedunless otherwisenoted.Formoreinformation,seethewebsite http://h18004.www1.hp.com/products/servers/platforms/storage.html IfyouareusingtheRapidDeploymentPack,seethesupportmatrixforthesupported serversonthewebsite http://www.hp.com/servers/rdp NOTE: Boot from SAN does not support the DL140 and DL145 line of servers. Servers BootfromSAN12
RequirementSupported feature HPEmulex8GbPCI-Expresssingleporthostbusadapter,partnumberAJ762A HPEmulex8GbPCI-Expressdualporthostbusadapter,partnumberAJ763A HPEmulexFibreChannelmezzanineHBAforHPp-classsystemsforBL30pG1,BL25p, BL35p,andBL45p,partnumber394588-B21 HPEmulexFibreChannelmezzanineHBAforHPp-classsystemsforBL20pG3,part number394757-B21 HPEmulexLPe1105-HP4GbFCHBAforHPc-ClassBladeSystem,partnumber 403621-B21 HPQLogic8GbPCI-Expresssingleporthostbusadapter,partnumberA334A HPQLogic8GbPCI-Expressdualporthostbusadapter,partnumberAJ764A HPQLogicQMH24624GbFCHBAforHPc-ClassBladeSystem,partnumber 403619-B21 HPQLogicDualPortFibreChannelMezzanineHBA2-GbforBL20Gp2G2,part number300874-B21 1050EXPCI-Expresshostbusadapter,partnumberA7650A 64-bitPCItoFibreChannel1-GBhostbusadapterDS-KGPSA-CB,partnumber 176479-B21 A7387Adual-channelPCI-X2-GBhostbusadapter,partnumberA7650A A7388APCI-X2-GBhostbusadapter,partnumberA7388A FCA21012-GB,hostbusadapter,partnumber245299-B21 FCA2355DC2-GBPCI-Xhostbusadapter,partnumber308540-B21 FCA22142-GBPCI-Xhostbusadapter,partnumber281541-B21 FCA2214DC2-GBPCI-Xhostbusadapter,partnumber321835-B21 FCA24042-GBPCI-Xhostbusadapter,partnumber305573-B21 FCA2404DC2-GBPCI-Xhostbusadapter,partnumber323264-B21 FCA24082-GBPCI-Xhostbusadapter,partnumber343073-B21 FC2142SR4GbPCI-Expresshostbusadapter,partnumberA8002A FC2242SR4GbPCI-Expresshostbusadapter,partnumberA8003A FC21434GbPCI-X2.0hostbusadapter,partnumberAD167A FC22434GbPCI-X2.0hostbusadapter,partnumberAD168A FC11434GbPCI-Expresshostbusadapter,partnumberAE311A FC12434GbPCI-Expresshostbusadapter,partnumberAE312A HPBL20pG2FibreChannelMezzAdapter,productnumber300874-B21 HPBL20pG3FibreChanneladapter,productnumber361426-B21 HPBL30p/BL35pDual-PortFibreChanneladapter,productnumber354054-B21 HPBL25p/BL45pFibreChanneladapter,productnumber381881-B21 Forthelatestinformationonfirmware,driverandBIOSversions,aswellasLUN limitations,seethewebsite •http://h18006.www1.hp.com/storage/networking/index.html. HBAs Seethewebsitehttp://h18006.www1.hp.com/storage/networking/index.htmlfor thelatestinformationonthefollowing: •EmulexEFI-basedSetupUtility(ESBU) •EmulexEFIfirmware •HPSmartSetupMedia ExtensibleFirmware Interface(EFI) FibreChannelhostbusadapterssoftwareguideforWindows13
Restrictions ThefollowingsectionsdescriberestrictionsforbootingfromaSAN. Operating system restrictions Thefollowingoperatingsystemrestrictionsapply: MicrosoftWindowsoperatingsystemsrequireaunique,dedicateddiskforbooting.Therefore,each serverconnectedtoaRAIDarraymusthaveitsowndisk,orlogicalunitnumber(LUN),dedicatedfor bootingandoperatingsystemfiles.Datacanbeallocatedacrossboththebootdiskandtheremaining disks.Bootingfromarray-baseddiskpartitionsispossible. NOTE: For Windows Server 2003, a crash dump file will not be generated if the path to the system drive is different from the active path established if the system was booted at the time of a system crash. To ensure that a crash dump is created, move the system disk back to the active boot time path as soon as possible, after any failure. For detailed information a file creation, see the website http://download.microsoft.com/download/f/9/7/f9775acc-baa6-45cc-9dec-b82983705620/ Boot%20from%20SAN%20in%20Windows.doc Clustered server restrictions ThissectiondescribesclusteredserverrestrictionsforStorportminiportdrivers. Storport miniport driver restrictions •ForStorportminiportdriverrestrictions,seethefollowingMicrosoftarticles: •TosetupMSCSproperly,seeClusterisformedbyusingalocalquorumresourceafteracluster setupfailureinWindowsServer2003,availableatthewebsite http://support.microsoft.com/?kbid=888160 •ForbootfromSANandMSCSconfigurationsonWindowsServer2003systems,seetheup- datedStorportstoragedriver,version5.2.3790.2494thatisavailableforWindowsServer 2003availableatthewebsite http://support.microsoft.com/kb/912944/en-us AlsoseeHowtoaddaregistryvaluetoaWindowsServer2003-basedcomputerthatyou startfromaSANsothatthestartupdisk,thepagefiledisks,andtheclusterdisksareallon thesameSANfabric,availableonthewebsite http://support.microsoft.com/kb/886569/en-us •Toavoidimpropermodificationoftheregistry,usetheBootfromSANClusterRegistryUpdate utilitytoaddtheManageDisksOnSystemBuseskey.Downloadtheutility(BFSCLRegUp.exe) fromthewebsite http://h18006.www1.hp.com/storage/saninfrastructure.html •AminimumoftwoHBAportsperhostisrequiredforaHighAvailability(HA)configuration. Fordetailedinformation,seetheProLiantHighAvailabilitywebsite http://h18004.www1.hp.com/solutions/enterprise/highavailability/index.html BootfromSAN14
Reconfiguring HBA zoning to avoid time-out conditions InbootfromSANconfigurationswheretherearemorethantwoEmulexHBAsinthesamezoneas thebootHBA,atime-outconditionmayoccurwhenthebootHBAinteractswiththenon-bootHBAs, causingacrash-dumptonotbegenerated.Toavoidtime-outconditions,reconfigurethezoningso thatthebootinstanceforeachpathisinitsownzone,separatefromtheothernon-bootHBAs.This mayalsoresultinfasterboot-uptimes. Server replacement in the event of a server failure IfyouretainingtheoriginalHBAs,placethemintheircorrespondingPCIslotsonthereplacement server.IfyouarenotretainingtheoriginalHBAs,makesureto: •RebuildtheboottablewiththenewHBAIDinformation. •RemovetheoriginalHBAsfromtheirzones,andreplacethemwiththenewHBAs. •RemovetheoriginalHBAsfromtheirarraystoragepresentationandreplacethemwiththenew HBAs. Prerequisites TosetupbootingfromaSAN,youshouldbefamiliarwith: •EVA,MSA,orXPFibreChannelRAIDarrays.ThisinformationisintheRAIDarray. •Familiaritywithswitch-basedzoning.Forinformationaboutzoningforyourenvironment,seeyour switch’sinstallationguidedocumentation. Thefollowingproceduresarenotfullydescribedinthisdocument.However,inordertoperformboot fromSANsetupprocedures,youwillneedtocompletethem. •MSA,EVAandXP •HPhighlyrecommendscreatinganewbootLUNsothatyouwillbeginwithacleanandun- partitionedvirtualdisk. •Verifyingthatthestorageunitshavetheproperaccess. •Switchconfigurationsandzoning—Checktheswitchtoensuretherearenozoningconflicts.You mustsetupswitchzoningaspartofyourconfiguration. •IfyouareusingtheRapidDeploymentPack,seetheRDPdocumentation. Supported configurations Thisdocumentdescribessingle-server,cluster,multipathconfigurationsusing: •EVA •MSA •XP RAID arrays PerformthefollowingforEVA,MSA,andXParrays: •Verifythatallexistingstorageunits(virtualdisks)havetheproperaccesssettings. •Withswitch-basedconfigurations,ifzoningisenabled,checktheswitchtoensurethereareno zoningconflicts. FibreChannelhostbusadapterssoftwareguideforWindows15
Working with boot disk partitions •Beforecreatingabootdisk,youmuststartwithaclean,unpartitionedvirtualdisk. •CreateaLUNthatisatleast32GBforW2K3and46GbforW2K8. •WhenbootingfromaRAIDarraythathasothervirtualdisksattachedtootherservers,beaware thatwhensettingupbootingforthenewserver,theinstallationprogrammaydisplayalistof partitionsvisibleforloadingtheoperatingsystem.Thedisplaycontainsadiskforeverycontroller portaccessiblebytheHBA. •HPrecommendsthatonlyoneinstanceofthebootLUNbevisibletotheserverduringtheinitial installation.TheinstallationmayfailifmultipleinstancesofthebootLUNareavailabletothe server. Switch-based zoning Youmustbefamiliarwithswitch-basedzoning.Forspecificinformationaboutzoningforyour environment,seeyourswitch'sinstallationguide. Cabling options for single-channel HBAs SANbootissupportedinthezonedsingle-channelHBAconfigurations,asshowninFigure1through Figure6. Figure 1 Single server, two single-channel HBAs, one switch, straight-cable storage configuration . BootfromSAN16
Figure 2 Single server, two single-channel HBAs, one switch, cross-cable storage configuration . Figure 3 Single server, one HBA, one switch configuration . ThefollowingconfigurationsshowninFigure4andFigure5supportSCSIPORTorStorportminiport drivers. Figure 4 Single server, two single-channel HBAs, two switches, straight-cable HA storage configuration . FibreChannelhostbusadapterssoftwareguideforWindows17
Figure 5 Single server, two single-channel HBAs, two switches, straight-cable HA storage configuration . TheconfigurationshowninFigure6supportsSCSIPORTorStorportminiportdrivers. Figure 6 Clustered servers, four single-channel HBAs per server, two switches, cross-cable HA storage configuration . Cabling options for dual-channel HBAs Dual-channelHBAsaretypicallyusedwhenthenumberofserverPCIslotsislimited.Figure7through Figure12showthecablingoptionsfordual-channelHBAs. BootfromSAN18
Figure 7 Single server, one dual-channel HBA, one switch, straight-cable storage configuration . Figure 8 Single server, one dual-channel HBA, one switch, straight-cable storage configuration . Figure 9 Single server, one dual-channel HBA, two switches, cross-cable storage configuration . TheconfigurationshowninFigure10requiresaStorportminiportdriver. FibreChannelhostbusadapterssoftwareguideforWindows19
Figure 10 Single server, one dual-channel HBA, two switches, straight-cable HA storage configuration . Figure 11 Single server, one dual-channel HBA, two switches, cross-cable HA storage configuration . TheconfigurationshowninFigure12supportsStorportminiportdrivers. BootfromSAN20