Installation 31 4. If the UPS is powered up, you can be sure that the UPS Network Module is seated properly and communicating with the UPS by verifying that the UPS Data LED illuminates solid green, and then flashes regularly after 2 minutes. Connecting the UPS Network Module The UPS Network Module is provided to manage the attached servers. RJ 45 network patch panel cables are required to use this card. The RJ 45 network patch panel cables are not include d. Installing the UPS as a tower Before installing the unit, review and adhere to all warnings provided in " Precautions (on page 12)." Connecting the battery leads
Installation 32 WARNING: To prevent personal injury from electric shock or damage to the equipment, remove the battery lead labels, and verify that the ERM circuit breakers are in the Off position. Rotating the logo badge Gently pull out the logo badge, rotate it 90 degrees, and then replace it in the bezel.
Installation 33 Attaching the UPS front bezel Attaching the tower conversion stands WARNING: To reduce the risk of personal injury or damage to the equipment, the tower conversion stands must be properly attached when the unit is installed as a tower. Using the preinstalled screws, attach the tower conversion stands to the unit. Continuing the installation To continue the UPS installation, follow the instructions starting with " Connecting the serial communications port (on page 20)."
Installation 34 Installing the ERM as a tower Before installing the unit, review and adhere to all warnings provided in " Precautions (on page 12)." The tower stands and associated hardware ship with the UPS. Rotating the logo badge Gently pull out the logo badge, rotate it 90 degrees, and then replace it in the bezel.
Installation 35 Attaching the ERM front bezel Attaching the tower conversion stands WARNING: To reduce the risk of personal injury or damage to the equipment, the tower conversion stands must be properly attached when the unit is installed as a tower.
Installation 36 1. Using the preinstalled screws, attach the tower conversion stands to the unit. 2. Remove a screw from the inner -most, rear corner of the UPS and ERM. 3. To attach the tower brackets: o For the front bracket, use the mounting ear screws.
Installation 37 o For the rear bracket, use the screws removed from the chassis. Continuing the ERM installation To continue the ERM installation, follow the instructions starting with " Connecting the ERM to the UPS (on page 28)."
Installation 38 Installing the extension bars (if included)
Installation 39 Connecting and securing the power cords
UPS operations 40 UPS operations Modes of operation The UPS h as five modes of operation: • Standby mode (on page 40) • Operate mode (on page 40) • Configure mode (on page 41) • Battery mode (on page 41) • Auto -Bypass mode (on page 41) Standby mode In Standby mode: • No power is available at the UPS output receptacles. • The UPS charges the batteries as necessary. The UPS can be placed in Standby mode when the UPS is in Operate mode (on page 40). To place the UPS in Standby mode, press and hold the Off button until the audible alarm sounds and the Utility LED flashes. Power to the load ceases. When fault conditions occur in Standby mode, the UPS enters Converter Off mode ("UPS is in Converter Off mode" on page 55 ). IM PORT ANT : While in Standby mode, the UPS maintains the charge on the batteries, but no power is available at the output receptacles. The UPS remains in Standby mode until an alternate mode is selected or until utility power is removed. For the location of buttons, see " UPS front panel controls (on page 7)." For the location of LEDs, see " UPS front panel LED indicators (on page 7 )." Operate mode In Operate mode: • Power is available at the UPS receptacles. • The UPS charges the batteries as necessary. The UPS can be placed in Operate mode if the UPS is powered up and in Standby mode (on page 40). To place the UPS in Operate mode, press the On button. The Utility LED illuminates, indicating that power is available at the UPS output receptacles. The UPS acknowledges compliance with a short beep. If the UPS is off (no LEDs are illuminated), press the On and Battery Start buttons simultaneously to start the UPS on battery power. For the location of buttons, see " UPS front panel controls (on page 7)." For the location of LEDs, see " UPS front panel LED indicators (on page 7 )."