    							HPE R/T3000 G2 UPS 
    User Guide  
    Abstract 
    This document includes installation, configuration, and operation information for the HPE R/T3000 G2 UPS. This document is for the person who installs and maintains power products. Hewlett Packard Enterprise assumes you are qualified in the servicing of high- voltage 
    equipment and trained in recognizing hazards in products with hazardous energy levels.   Part Number: 651176-00
    3R a 
    November 2015 
    Edition: 4  
    						
    							© Copyright 2011, 2015 Hewlett Packard Enterprise Development LP 
    The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services 
    are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting 
    an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.  
    Microsoft®, Windows®, and Windows Server® are either registered trademarks or trademar ks of Microsoft Corporation in the United States 
    and/or other countries.    
    						
    							C
    
    ontents   3 
    Contents  
    Component identification  ....................................................................................................................... 6  
    UPS R/T3000 G2 overview ......................................................................................................................................  6 
    UPS front panel ........................................................................................................................................................ 6 
    UPS front panel controls  .......................................................................................................................................... 7 
    UPS front panel LED indic ators ................................................................................................................................  7 
    UPS R/T3000 models ...............................................................................................................................................  8 
    R/T3000 NA and R/T3000j JPN rear panel .............................................................................................................. 8 
    R/T3000h NA and R/T3000h JPN rear panel  ...........................................................................................................  9 
    R/T3000 INT rear panel ..........................................................................................................................................  10 
    REPO port ..............................................................................................................................................................  10 
    ERM rear panel  ......................................................................................................................................................  11 
    Installation  ...........................................................................................................................................  12 
    Precautions ............................................................................................................................................................  12 
    Preparing to install the hardware  ............................................................................................................................  12 
    Tools and materials  .....................................................................................................................................  12 
    Selecting a site  ............................................................................................................................................  13 
    Readying the equipment..............................................................................................................................  13 
    Installing the mounting rails  ....................................................................................................................................  13 
    Installing the UPS in a rack ....................................................................................................................................  16 
    Connecting the battery leads .......................................................................................................................  17 
    Attaching the UPS front bezel  .....................................................................................................................  19 
    Connecting the host computer .....................................................................................................................  19 
    Connecting the REPO port  ..........................................................................................................................  20 
    Connecting the ground bonding cable .........................................................................................................  22 
    Connecting the UPS to utility power  ............................................................................................................  23 
    Connecting devices to the UPS ...................................................................................................................  23 
    Connecting the UPS cord retention clips  .....................................................................................................  24 
    Charging the UPS batteries  .........................................................................................................................  24 
    Starting power to the load............................................................................................................................  25 
    Installing the ERM in a rack  ....................................................................................................................................  25 
    Connecting the battery leads .......................................................................................................................  26 
    Attaching the ERM front bezel  .....................................................................................................................  27 
    Connecting the ERM to the UPS  .................................................................................................................  28 
    Switching on the ERM circuit breaker ..........................................................................................................  29 
    Charging the ERM batteries ........................................................................................................................  29 
    Installing the optional UPS Network Module ..........................................................................................................  30 
    Connecting the UPS Network Module .........................................................................................................  31 
    Installing the UPS as a tower  ................................................................................................................................ . 31 
    Connecting the battery leads  .......................................................................................................................  31 
    Rotating the logo badge  ..............................................................................................................................  32 
    Attaching the UPS front bezel  .....................................................................................................................  33 
    Attaching the tower conversion stands  ........................................................................................................  33 
    Continuing the installation ...........................................................................................................................  33 
    Installing the ERM as a tower  ................................................................................................................................ . 34 
    Rotating the logo badge  ..............................................................................................................................  34 
    Attaching the ERM front bezel  .....................................................................................................................  35 
    Attaching the tower conversion st ands ........................................................................................................  35 
    Continuing the ERM installation ..................................................................................................................  37 
    Installing the extension bars (if included) ...............................................................................................................  38 
    Connecting and securing the power cords  .............................................................................................................  39 
    UPS  operations ....................................................................................................................................  40 
    Modes of operation .................................................................................................................................................  40 
    Standby mode  .............................................................................................................................................  40  
    						
    							 
    Contents  4 
    Operate mode ................................ .............................................................................................................. 40 
    Configure mode  ................................ ........................................................................................................... 41 
    Battery mode  ................................ ............................................................................................................... 41 
    Auto- Bypass mode  ................................ ...................................................................................................... 41 
    Operating the UPS front panel controls  ................................ .................................................................................. 41 
    Configuring the UPS  ................................ ............................................................................................................... 42 
    Initiating a self -test  ................................ ................................................................................................................. 43 
    Silencing an audible alarm  ................................ ..................................................................................................... 43 
    Verifying the REPO port connection  ................................ ....................................................................................... 44 
    Powering down the UPS  ................................ ........................................................................................................ 44 
    Maintenance  ........................................................................................................................................  45 
    Removing the UPS front bezel ................................ ............................................................................................... 45 
    Removing the ERM front bezel  ................................ .............................................................................................. 45 
    Replacing the batteries  ................................ ........................................................................................................... 45 
    Important battery safety information  ................................ ............................................................................ 46 
    Battery care and storage guidelines  ................................ ............................................................................ 46 
    Determining when to replace batteries  ................................ ........................................................................ 46 
    Obtaining new batteries  ................................ ............................................................................................... 47 
    UPS battery replacement procedure  ........................................................................................................... 47 
    Testing the new battery module  .................................................................................................................. 48 
    Replacing the UPS  ................................ ................................................................................................................. 48 
    Replacing the ERM  ................................ ................................................................................................................ 49 
    Replacing the UPS option card  .............................................................................................................................. 49 
    Updating the UPS firmware  ................................ .................................................................................................... 50 
    Configuring a USB to serial converter  ................................ ......................................................................... 50 
    Reassigning the USB COM ports  ................................ ................................................................................ 51 
    Power management  .............................................................................................................................  53 
    Power Protector software ....................................................................................................................................... 53 
    Troubleshooting  ...................................................................................................................................  54 
    LED troubleshooting ................................ ............................................................................................................... 54 
    UPS is in Auto- Bypass mode ................................ ................................................................................................. 55 
    UPS is in Converter Off mode  ................................................................................................................................ 55 
    General alarm condition  ......................................................................................................................................... 56 
    Bypass is out of range  ................................ ............................................................................................................ 56 
    Battery condition  ................................ ..................................................................................................................... 57 
    UPS is on battery  ................................ ................................................................................................................... 57 
    Input voltage is out of range  ................................ ................................................................................................... 57 
    Overtemperature condition  ..................................................................................................................................... 57 
    Internal UPS fault condition  ................................ .................................................................................................... 57 
    REPO condition  ................................ ...................................................................................................................... 57 
    Site wiring condition  ................................ ............................................................................................................... 58 
    Overload condition  ................................ ................................................................................................................. 58 
    Checksum failure error  ................................ ........................................................................................................... 58 
    UPS does not start  ................................ ................................................................................................................. 58 
    Low battery shutdowns  ................................ ........................................................................................................... 58 
    UPS does not provide the expected backup time  .................................................................................................. 59 
    UPS frequently switches between utility and battery power  ................................ ................................................... 59 
    Specifications  ......................................................................................................................................  60 
    UPS physical specifications ................................ ................................................................................................... 60 
    ERM physical specifications  ................................ ................................................................................................... 60 
    UPS input specifications  ................................ ......................................................................................................... 60 
    UPS output specifications  ................................ ...................................................................................................... 60 
    Power protection specifications  ................................ ................................................................................... 61 
    Output tolerance specifications  ................................ ................................................................................... 61 
    Output feature specifications  ................................ ....................................................................................... 61 
    Battery specifications  ................................ ............................................................................................................. 61 
    High -voltage UPS battery runtimes  ................................ ........................................................................................ 62 
    Low -voltage UPS battery runtimes  ................................ ......................................................................................... 62  
    						
    							 
    Contents  5 
    Environmental specifications  ................................ .................................................................................................. 62 
    REPO port specifications  ................................ ....................................................................................................... 62 
    Spares  .................................................................................................................................................  63 
    Ordering spares ................................ ...................................................................................................................... 63 
    UPS spare parts list  ................................ ................................................................................................................ 63 
    ERM spare parts list  ................................ ............................................................................................................... 64 
    Hardware options  ................................ ................................................................................................................... 64 
    Support and other resources ................................................................................................................  65 
    Accessing Hewlett Packard Enterprise Support ................................ ..................................................................... 65 
    Information to collect  ................................ ................................................................................................... 65 
    Accessing updates  ................................ ................................................................................................................. 65 
    Websites  ................................ ................................................................................................................................. 65 
    Customer Self Repair  ................................ ............................................................................................................. 66 
    Remote support  ................................ ...................................................................................................................... 73 
    Warranty and regulatory information  ....................................................................................................  74 
    Warranty information .............................................................................................................................................. 74 
    Regulatory information  ................................ ........................................................................................................... 74 
    Safety and regulatory compliance  ............................................................................................................... 74 
    Turkey RoHS material content declaration  ................................ .................................................................. 74 
    Ukraine RoHS material content declaration  ................................ ................................................................ 74 
    Acronyms and abbreviations  ................................................................................................................  75 
    Documentation feedback  .....................................................................................................................  76 
    Index  ....................................................................................................................................................  77 
      
    						
    							C
    
    omponent identification  6 
    C omponent identification 
    UPS R/T3000 G2 overview  
    The UPS R/T3000 G2 features a 2U rack -mount with convertible tower design and offers power protection 
    for loads up to a maximum of 3300 VA/3000 W (these numbers might vary by model).  
    To benefit from the latest product enhancements, update to the latest versions of UPS firmware and 
    software.  
    N
     OTE:
      To download the latest versions of UPS firmware and software, see the Hewlett 
    Packard Enterprise website  (http://www.hpe.com/info/rackandpower ). 
    U PS front panel  
    Item Description 
    1 Battery compartment 
    2 Front panel display  
    						
    							 
    Component identification  7 
    U PS front panel controls  
            
    Item Description   Function 
    1 Test/Alarm Reset button Silences UPS alarms ("Silencing an audible 
    alarm " on page 43 ) 
    2  Off button Places the UPS in Standby mode (on page 
    40)  
    3 On button Powers up the UPS ("Starting power to the 
    load " on page  25) 
    4 Battery Start button Starts the UPS on battery power when 
    pressed with the On button    
    UPS front panel LED indicators  
     
    The front panel is sho wn with the bezel removed.   
    						
    							C
    
    omponent identification  8 
    Item  LED 
    description  Load level
     
    1 Self Test On—The load level is greater than 10%. 
    2 Battery Fault On—The load level is greater than 25%. 
    3 Site W iring Fault On—The load level is greater than 50%. 
    4 Overtemperature On—The load level is greater than 75%. 
    5 Overload On—The load level is greater than 100%. 
    6 On Bypass 
    7 On Battery 
    8 Utility 
    For more information, see "LED troubleshooting (on page 54 )" . 
    UPS R/T3000 models         
    UPS model  Description 
    R/T3000 NA and R/T3000j JPN  • Domestic/Japanese 
    •Low-voltage
    •Nondetachable NEMA L5-30 plug
    R/T3000h NA and R/T3000h 
    JPN •Domestic
    •High -voltage
    •Nondetachable NEMA L6-20 plug
    R/T3000 INT  •International
    •High-voltage
    •Detachable country -specific plug
    R/T3000 NA and R/T3000j JPN rear panel  
    Item Description 
    1 UPS option card 
    2 USB communications port 
    3 Serial communications port 
    4 Load segment circuit breaker  
    						
    							 
    Component identification  9 
    Item Description 
    5  Load segment 1 (two NEMA 5-20R T-Slot receptacles) 
    6 Load segment circuit breaker  
    7 Load segment 2 (two NEMA 5-20R T-Slot receptacles) 
    8 PDU output (NEMA L5-30R) receptacle (load segment 1)  
    9 Cord retention clip attachment location 
    10 Cord retention clip attachment location 
    11 Ground bonding screw  
    12 Power cord with L5-30 plug   
    R/T3000h NA and R/T3000h JPN rear panel  
         
    Item   Description  
    1 UPS option card 
    2 USB communications port 
    3 Serial communications port 
    4 Ground bonding screw  
    5 Load segment 1 and 2 (one IEC-320-C19 receptacle) 
    6 Load segment 1 (three IEC-320-C13 receptacles) 
    7 Load segment 2 (three IEC-320-C13 receptacles) 
    8 PDU output (L6-20) receptacle (load segment 1) 
    9 Cord retention clip attachment location 
    10 Cord retention clip attachment location 
    11 Cord retention clip attachment location 
    12 Ground bonding screw  
    13 REPO port  
    14 Power cord with L6-20 plug    
    						
    							C
    
    omponent identification  10 
    R/T3000 INT rear panel  
    Item Description 
    1 UPS option card 
    2 USB communications port 
    3 Serial communications port 
    4 Ground bonding screw 
    5 Load segment 1 and 2 (one IEC-320-C19 receptacle) 
    6 Load segment 1 (three IEC-320-C13 receptacles) 
    7 Load segment 2 (three IEC-320-C13 receptacles) 
    8 Cord retention clip attachment location 
    9 Cord retention clip attachment location 
    10 Cord retention clip attachment location 
    11 Ground bonding screw 
    12 REPO port 
    13 Input power receptacle (IEC-320-C20) for country-specific plug 
    attachment  
    REPO port 
    The UPS includes an isolated REPO port. When properly wired, the REPO feature enables the power at 
    the UPS output receptacles to be switched off from a remote location. To use this feature, the REPO port 
    must be connected to a remote, normally -open switch (not supplied). The REPO switch is used in 
    conjunction with a main disconnect device that removes the AC source from the input of the UPS. When 
    the switch is closed:  
    •The REPO feature immediately powers down protected devices and does not utilize the orderly
    s
    
    hutdown procedure initiated by power management software.
    •The REPO feature shuts down UPS units operating under either utility or battery power.
    N
     OTE:
      If the UPS was operating on battery power when the remote switch was closed, no 
    power is available  to the load devices until utility power is restored and the UPS has been 
    manually powered up.   
    						