Home > HP > Notebook > HP 6730b Service Manual

HP 6730b Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual HP 6730b Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1114 HP manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							S-Video-out
    PinSignal
    1Ground (Y)
    2Ground (C)
    3Y intensity (luminance)
    4 C color (Chrominance
    S-Video-out 151 
    						
    							Serial port
    PinSignal
    1Data carrier detect
    2Received data
    3Transmitted data
    4Data terminal ready
    5Signal ground
    6Data set ready
    7Request to send
    8Clear to send
    9 Ring indicator
    Universal Serial Bus
    PinSignal
    1+5 VDC
    2Data -
    3Data +
    4 Ground
    152 Chapter 9   Connector pin assignments 
    						
    							10 Power cord set requirements
    The wide range input feature of the computer permits it to operate from any line voltage from 100 to 120
    volts AC or from 220 to 240 volts AC.
    The 3-conductor power cord set included with the computer meets the requirements for use in the
    country or region where the equipment is purchased.
    Power cord sets for use in other countries and regions must meet the requirements of the country or
    region where the computer is used.
    Requirements for all countries and regions
    The requirements listed below are applicable to all countries and regions:
    ●The length of the power cord set must be at least 1.5 m (5.0 ft) and no more than 2.0 m (6.5 ft).
    ●All power cord sets must be approved by an acceptable accredited agency responsible for
    evaluation in the country or region  where the power cord set will be used.
    ●The power cord sets must have a minimum current capacity of 10 amps and a nominal voltage
    rating of 125 or 250 V AC, as required by the power system of each country or region.
    ●The appliance coupler must meet the mechanical configuration of an EN 60 320/IEC 320 Standard
    Sheet C13 connector for mating with the appliance inlet on the back of the computer.
    Requirements for all countries and regions 153 
    						
    							Requirements for specific countries and regions
    Country/regionAccredited agencyApplicable note number
    AustraliaEANSW1
    AustriaOVE1
    BelgiumCEBC1
    CanadaCSA2
    DenmarkDEMKO1
    FinlandFIMKO1
    FranceUTE1
    GermanyVDE1
    ItalyIMQ1
    JapanMETI3
    The NetherlandsKEMA1
    NorwayNEMKO1
    The Peoples Republic of ChinaCCC5
    SwedenSEMKO1
    South KoreaEK1
    SwitzerlandSEV1
    TaiwanBSMI4
    The United KingdomBSI1
    The United StatesUL2
    1.The flexible cord must be Type HO5VV-F, 3-conductor, 1.0-mm² conductor size. Power cord set fittings (appliance coupler
    and wall plug) must bear the certification mark of the agency responsible for evaluation in the country or region where it
    will be used.
    2.The flexible cord must be Type SPT-3 or equivalent, No. 18 AWG, 3-conductor. The wall plug must be a two-pole grounding
    type with a NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.
    3.The appliance coupler, flexible cord, and wall plug must bear a “T” mark and registration number in accordance with the
    Japanese Dentori Law. The flexible cord must be Type VCT or VCTF, 3-conductor, 1.00-mm² conductor size. The wall
    plug must be a two-pole grounding type with a Japanese Industrial Standard C8303 (7 A, 125 V) configuration.
    4.The flexible cord must be Type RVV, 3-conductor, 0.75-mm² conductor size. Power cord set fittings (appliance coupler
    and wall plug) must bear the certification mark of the agency responsible for evaluation in the country or region where it
    will be used.
    5.The flexible cord must be Type VCTF, 3-conductor, 0.75-mm² conductor size. Power cord set fittings (appliance coupler
    and wall plug) must bear the certification mark of the agency responsible for evaluation in the country or region where it
    will be used.
    154 Chapter 10   Power cord set requirements 
    						
    							11 Recycling
    Battery
    When a battery has reached the end of its useful life, do not dispose of the battery in general household
    waste. Follow the local laws and regulations in your area for computer battery disposal.
    Display
    WARNING!The backlight contains mercury. Exercise caution when removing and handling the
    backlight to avoid damaging this component and causing exposure to the mercury.
    CAUTION:The procedures in this appendix can result in damage to display components. The only
    components intended for recycling purposes are the liquid crystal display (LCD) panel and the backlight.
    Careful handling must be exercised when removing these components. When you remove these
    components, handle them carefully.
    NOTE:Materials Disposal. This HP product contains mercury in the backlight in the display assembly
    that might require special handling at end-of-life. Disposal of mercury may be regulated because of
    environmental considerations. For disposal or recycling information, contact your local authorities, or
    see the Electronic Industries Alliance (EIA) Web site at 
    http://www.eiae.org.
    This section provides disassembly instructions for the display assembly. The display assembly must be
    disassembled to gain access to the backlight (1) and the liquid crystal display (LCD) panel (2).
    NOTE:The procedures provided in this appendix are general disassembly instructions. Specific
    details, such as screw sizes, quantities, and locations, and component shapes and sizes, can vary from
    one computer model to another.
    Battery 155 
    						
    							Perform the following steps to disassemble the display assembly:
    1.Remove all screw covers (1) and screws (2) that secure the display bezel to the display assembly.
    2.Lift up and out on the left and right inside edges (1) and the top and bottom inside edges (2) of the
    display bezel until the bezel disengages from the display assembly.
    3.Remove the display bezel (3).
    156 Chapter 11   Recycling 
    						
    							4.Disconnect all display panel cables (1) from the display inverter and remove the inverter (2).
    5.Remove all screws (1) that secure the display panel assembly to the display enclosure.
    6.Remove the display panel assembly (2) from the display enclosure.
    7.Turn the display panel assembly upside down.
    8.Remove all screws that secure the display panel frame to the display panel.
    9.Use a sharp-edged tool to cut the tape (1) that secures the sides of the display panel to the display
    panel frame.
    Display 157 
    						
    							10.Remove the display panel frame (2) from the display panel.
    11.Remove the screws (1) that secure the backlight cover to the display panel.
    12.Lift the top edge of the backlight cover (2) and swing it outward.
    13.Remove the backlight cover.
    14.Turn the display panel right-side up.
    158 Chapter 11   Recycling 
    						
    							15.Remove the backlight cables (1) from the clip (2) in the display panel.
    16.Turn the display panel upside down.
    WARNING!The backlight contains mercury. Exercise caution when removing and handling the
    backlight to avoid damaging this component and causing exposure to the mercury.
    17.Remove the backlight frame from the display panel.
    Display 159 
    						
    							18.Remove the backlight from the backlight frame.
    19.Disconnect the display panel cable (1) from the LCD panel.
    20.Remove the screws (2) that secure the LCD panel to the display rear panel.
    21.Release the LCD panel (3) from the display rear panel.
    22.Release the tape (4) that secures the LCD panel to the display rear panel.
    23.Remove the LCD panel.
    24.Recycle the LCD panel and backlight.
    160 Chapter 11   Recycling 
    						
    All HP manuals Comments (0)