    							6.ClickOK.
    TheBackupManagerpagedisplaysthefollowingstatusmessage:
    7.ClickBacktore-displaytheBackupManagerpage.
    NOTE:Torestoreabacked-upcodeorconfigurationfile,useUpdateManager.
    UpdateManager
    TheUpdateManagerpageenablesanewimageorconfigurationfiletobeuploadedfromthe
    localsystemornetworktotheswitch.
    UpdateManagerdisplaysdifferentoptionsdependingonthetransferprotocol,fileorimagetype
    selectedforanupdate.IntheexampleinFigure47,theinactive(or“Backup”)imageontheswitch
    isbeingupdatedfromaTFTPserver.Forexample,iftheimage1fileisbeingusedasthecurrently
    activeimagerunningontheswitch,thentheimage2fileisthebackupfiletobeupdated.
    TodisplaytheUpdateManagerpage,clickMaintenance>UpdateManagerinthenavigation
    pane.
    Figure47UpdateManagerPage
    Table36UpdateManagerFields
    DescriptionField
    Selecttheprotocoltouse:UpdateMethod
    •HTTP—ThefileisdownloadedusingHTTPfromalocalorremotedrive.
    •TFTP—ThefileisdownloadedusingTFTPfromaTFTPserveroperatingon
    thesystem/network.
    IfHTTPisusedforthesoftwareupdate,clickBrowsetoselectthedesignated
    file.
    Browseforfile(HTTPuploadonly)
    UpdateManager61 
    						
    							Table36UpdateManagerFields(continued)
    DescriptionField
    NOTE:Ifthefilenamediffersfromthedefaultnameontheswitch,thefile
    willberenamedtothedefaultnamewhenuploaded(seetheUpdateType
    fielddescription).
    IfaTFTPdownloadisperformed,entertheIPaddressoftheTFTPserver.ServerIP(TFTPuploadonly)
    IfaTFTPdownloadisperformed,enterthename,andfilepathasneeded,
    ofthesoftwareupdatefileontheTFTPserver.
    FileName(TFTPuploadonly)
    Selectthefiletypetobeupdated:UpdateType
    •Code—Updatethesoftwareimagefilespecified.
    •Configuration—Updateuptheconfigurationfile.
    •ToupdateanSSLcertificateorkeyencryptionfile,selectthecertificate
    type(foradescriptionofthesefiles,see“SecureConnection”(page39):
    •SSLTrustedRootCertificatePEMFile—SSLTrustedRootCertificateFile
    whichisencodedusingthePrivacyEnhancedMail(PEM)protocol.
    •SSLServerCertificatePEMFile—SSLServerCertificateFile(PEM-encoded).
    •SSLDHWeakEncryptionParameterPEMFile—SSLDiffie-HellmanWeak
    EncryptionParameterFile(PEMencoded).
    •SSLDHStrongEncryptionParameterPEMFile—SSLDiffie-HellmanStrong
    EncryptionParameterFile(PEMencoded).
    IfCodeisselectedastheupdatetype,selectwhichofthetwoimagesstored
    ontheswitchistobeupdated:
    Image(forCodeupdatesonly)
    •Active—Theuploadedimagewillreplacethecurrentlyactiveimage.
    •Backup—Theuploadedimagewillreplacethebackupimage.
    Example—UpdatingtheSwitchSoftware
    CAUTION:Itisrecommendedthatyoubackuptheimagefilebeforeupdatingit.See“Backup
    Manager”(page59)forinstructions.
    Followtheseinstructionstoupdatetheswitchsoftware(thatis,afirmwarecodeimage):
    1.IntheUpdateMethodfield,selecttheprotocoltousetouploadthefiletothesystem.Ifthe
    fileislocatedonalocalornetworkdrive,selectHTTP.IfthefileislocatedonaTFTPserver,
    selectTFTP.
    2.IfTFTPisselected,specifytheIPaddressoftheTFTPserver,thepathtothefile,andthename
    ofthefileasitappearsontheserver.
    IfHTTPisselected,browsetolocatethefileonyournetworkorlocaldrive.
    3.IntheUpdateTypefield,selectCode.
    4.IntheImagefield,chooseBackuporActive.
    IfyouchooseBackup,theinactive(backup)imagefilewillbeupdated.Intheexamplein
    Figure10-2onpage10-4,theBackupimagefileisselectedforupdate.
    IfyouchooseActive,theactiveimagefilewillbeupdated.
    5.ClickDownload.
    Awarningpagelikethefollowingdisplays(thetextmaydifferdependingontheprotocol
    selected):
    62MaintenancePages  
    						
    							6.ClickOK.
    Thefollowingpagedisplays:
    7.ClickOK.
    ThefollowingmessagedisplaysontheUpdateManagerpage:
    Code (Configuration) download through HTTP (TFTP) is in Progress.
    Please wait...
    Whenthetransferiscomplete,awindowlikethefollowingdisplays:
    8.ClickOK.
    UpdateManagerdisplaysthefollowingstatusmessage:
    UpdateManager63 
    						
    							9.ClickBacktore-displaytheUpdateManagerpage.
    Notethat,inthisexample,theimagewasdownloadedastheinactive(backup)image.To
    completetheupdateprocessandtoactivatethebackupimageastheoperatingsoftware,
    usetheDualImageConfigurationpage.
    Inthefollowingexample,Image1istheactiveimage,andImage2isthenewlyupdated
    backupimage.ByclickingActivate,Image2willbeactivatedonthenextreboot(andImage1
    willbecometheinactivebackupimage).
    10.(Optional)Addadescriptionfortheselectedimage(Image2)andclickApply.
    11.ClickActivatetoactivatetheselectedimageonthenextreboot.
    NOTE:YoucanverifythenextactiveimagebyviewingtheStatus>DualImagescreen.
    12.ClickDiagnostics>RebootSwitch,andthenclickRebootSwitchtocompletetheupdate.
    Waitfortheswitchtorebootanddisplaytheloginpage.
    PasswordManager
    UsethePasswordManagertochangethepasswordusedtoaccesstheWebinterface.
    TodisplaythePasswordManagerpage,clicktheMaintenance>PasswordManager.
    64MaintenancePages 
    						
    							Figure48PasswordManagerPage
    NOTE:Thereisnodefaultpassword.Passwordsmustbeatleast8charactersbutnomorethan
    64characterslong.Passwordsarecasesensitive.Thereisnodefaultpassword.Passwordsare
    upto64alpha-numericandspecialcharacters
    (~,`,!,@,#,$,%,^,&,*,(,),-,_,+,=,{,[,},],|,\,,.,?,/",'andspace)inlength,andarecasesensitive.
    Thepasswordneedstobeenteredagaintoconfirmnewpassword.Incaseofaforgottenpassword,
    manuallyresettheswitchtoitsfactorydefaults.
    Entertheoldpasswordandthenewpasswordtwice,andclickApply.Atthenextlogon,usethe
    newpassword.
    DualImageConfiguration
    UsetheDualImageConfigurationpagetonameandchangethenextbootupimage.TheDual
    ImageConfigurationallowsactivatingeitherofthestoredimages:Image1orImage2.Whenone
    imageisactivated,theotherimageservesasabackup;ifImage1eitherfailsordoesnotboot,
    thentheotherimagecanbeactivated.
    TodisplaytheDualImageConfigurationpage,clickMaintenance>DualImageConfiguration.
    Figure49DualImageConfigurationPage
    Table37DualImageConfigurationFields
    DescriptionField
    Selecttheimageyouwanttoperformanactionon.Youcanactivatetheselectedimage,
    deleteit,orconfigureadescriptionofit.OptionsareImage1andImage2.
    ImageName
    Thecurrentlyactiveimage.ActiveImage
    SpecifyadescriptionoftheimageselectedintheImageNamefield.ImageDescription
    Thesoftwareversionassociatedwiththeactiveimage.ImageVersion
    •ClickActivatetoactivatetheselectedimageselectedintheImageNamefield.Besureto
    configuretheImageDescriptionfieldtotheversionoftheimageloadedsothatuserscan
    easilydistinguishbetweentheimages.
    •ClickApplytoapplyadescriptiontotheimageselectedintheImageNamefield.
    •ClickDeletetodeletetheimageselectedintheImageNamefield.
    DualImageConfiguration65 
    						
    							Toviewdualimagestatusinformation,clickStatus>DualImageStatusinthenavigationpane.
    66MaintenancePages 
    						
    							11Supportandotherresources
    ContactingHP
    Forworldwidetechnicalsupportinformation,seetheHPSupportCenter:
    http://www.hp.com/go/hpsc
    BeforecontactingHP,collectthefollowinginformation:
    •Productmodelnamesandnumbers
    •Technicalsupportregistrationnumber(ifapplicable)
    •Productserialnumbers
    •Errormessages
    •Operatingsystemtypeandrevisionlevel
    •Detailedquestions
    SubscriptionService
    HPstronglyrecommendsthatcustomersregisteronlineusingtheSubscriber'schoicewebsite:
    http://www.hp.com/go/e-updates.
    Subscribingtothisserviceprovidesyouwithe-mailupdatesonthelatestproductenhancements,
    newestdriverversions,andfirmwaredocumentationupdatesaswellasinstantaccesstonumerous
    otherproductresources.
    Aftersubscribing,locateyourproductsbyselectingBusinesssupportandthenStorageunder
    ProductCategory.
    Typographicconventions
    Table38Documentconventions
    ElementConvention
    Bluetext:Table38(page67)•Cross-referencelinksande-mailaddresses
    •Acrossreferencetotheglossarydefinitionoftheterm
    inbluetext
    emailaddressesBlue,bold,underlinedtext
    WebsiteaddressesBlue,underlinedtext:http://www.hp.com
    Boldtext•Keysthatarepressed
    •TexttypedintoaGUIelement,suchasabox
    •GUIelementsthatareclickedorselected,suchasmenu
    andlistitems,buttons,tabs,andcheckboxes
    TextemphasisItalictext
    ContactingHP67 
    						
    							Table38Documentconventions(continued)
    ElementConvention
    Monospace text•Fileanddirectorynames
    •Systemoutput
    •Code
    •Commands,theirarguments,andargumentvalues
    Monospace, italic text•Codevariables
    •Commandvariables
    EmphasizedmonospacetextMonospace, bold text
    WARNING!Indicatesthatfailuretofollowdirectionscouldresultinbodilyharmordeath.
    CAUTION:Indicatesthatfailuretofollowdirectionscouldresultindamagetoequipmentordata.
    IMPORTANT:Providesclarifyinginformationorspecificinstructions.
    NOTE:Providesadditionalinformation.
    TIP:Provideshelpfulhintsandshortcuts.
    68Supportandotherresources     
    						
    							12Documentationfeedback
    HPiscommittedtoprovidingdocumentationthatmeetsyourneeds.Tohelpusimprovethe
    documentation,sendanyerrors,suggestions,orcommentstoDocumentationFeedback
    ([email protected]).Includethedocumenttitleandpartnumber,versionnumber,ortheURL
    whensubmittingyourfeedback.
    69 
    						
    							Index
    B
    BackupManagerpage,59
    browsersupport,7
    C
    ClockStatusfields,24
    ClockStatuspage,23
    contactingHP,67
    conventions
    document,67
    textsymbols,68
    D
    DaylightSavingTime,28
    diagnostics,54
    Diffie-Hellman,41
    document
    conventions,67
    documentation
    providingfeedbackon,69
    DualImageConfigurationpage,65
    DualImageStatusfields,23
    DualImageStatuspage,22
    E
    EEE,52
    seealsoEnergyEfficientEthernet
    EnergyEfficientEthernet,52
    seealsoEEE
    F
    factorydefaults,56
    features
    supported,5
    flowcontrol,33
    G
    Greenfeatures,34
    GreenFeaturesStatusfields,22
    GreenFeaturesStatuspage,21
    H
    help
    obtaining,67
    HP
    Subscriber'schoicewebsite,67
    technicalsupport,67
    J
    jumboframes,32
    L
    LinkLayerDiscoveryProtocol,50
    seealsoLLDP
    LLDP,50
    seealsoLinkLayerDiscoveryProtocol
    configuration,50
    localdevice,51
    remotedevice,52
    LLDPStatisticspage,15
    LocatorLED,57
    log
    configuration,54
    LogStatuspage,13
    loopprotection,35
    LoopProtectionStatuspage,18
    M
    MACTablepage,17
    maintenancepages,59
    N
    networkconnection,7
    O
    operatingsystem,7
    P
    PasswordManager,64
    PingTest,54
    Portconfiguration,31
    PortLEDs,11
    portmirroring,32
    PortSummarypage,14
    R
    reboot,55
    S
    secureconnection,39
    security,39
    SimpleNetworkTimeProtocol,27
    seealsoSNTP
    SNTP,27
    seealsoSimpleNetworkTimeProtocol
    SNTPfields,27
    SpanningTreefields,21
    SpanningTreeStatuspage,19
    SSLcertificates,41
    statistics
    viewing,12
    Statuspages,12
    Subscriber'schoice,HP,67
    supportfile,56
    symbolsintext,68
    systeminformation
    viewing,12
    SystemLEDs,11
    T
    technicalsupport
    70Index 
    						
    All HP manuals Comments (0)