Honeywell Yth8320zw1007u Manual
Have a look at the manual Honeywell Yth8320zw1007u Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ELAN Home Systems ● 1690 Corporate Circle ● Petaluma, CA 94954 USA tech support: 800.622.3526 • main: 760.710.0990 • sales: 877.289.3526 • email: [email protected] ©2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners. Integration Note Manufacturer: Honeywell Model Number(s): YTH8320ZW1007/U Thermostats / Leviton VRC0P-1LW (+3) RS-232 Adapter Minimum Core Module Version: g! 5.8 Document Revision Date: 2/15/2013 OVERVIEW AND SUPPORTED FEATURES The Honeywell YTH8320ZW1007/U thermostats are wireless Z-Wave thermostats capable of controlling gas, oil, electric heat with air conditioning, warm air, hot water, high efficiency furnaces, heat pumps, steam , gravity, heat only, heat only with fan, cool only and 750mV heating systems. The YTH8320ZW1007/U thermostats are remote controllable over Z-Wave 900mhz wireless mesh networks via the use of a Z-Wave RS-232 adapter, enabling 2-way control and feedback from g!. The g! system supports up to 16 wireless thermostats. Note: Z-Wave RF operates at 900MHz. Any other devices operating on the same frequency may cause interference and need to be removed. Leviton recommends the system in installations of 7500 square feet or less and installing devices typically no more than 30 feet apart. Please refer to the Leviton Vizia RF Systems Guide (www.ViziaRF.com) for other installation considerations and details on proper setup of the Z-Wave networks. Additional information can be found at www.z-wave.com. THE YTH8320ZW1007/U DRIVER SUPPORTS THE FOLLOWING FEATURES: Auto Discovery: Thermostats may be auto-detected and added into g! Decimal Temperature Control: g! Core module 5.5 added support for decimal temperature display. Honeywell’s YTH8320ZW1007/U thermostat set points can be set to .5 degree increments in Celsius mode only. Feedback on the g! UI’s is in .5 degree increments for Celsius mode. History View: The history view shows the inside temperature, outside temperature, unit run times, and cooling and heating set points. Mode Control: The climate system can be set to run in the following heating and cooling modes: Heat only, Cool only, Auto, Off or EHeat (Heat Pump Only). Fan Modes: On, Auto, Circulate Schedule Control: Scheduling is supported from the Viewer. The YTH8320ZW1007/U Built-in Schedule must be disabled to use g! scheduling. Shared Z-Wave Network: A single Leviton Vizia RF Z-Wave network may contain Door Locks, Thermostats, and Lights. All three may be controlled over a single RS-232 Z-Wave adapter. See the appropriate Z-Wave Door Lock and Z-Wave Lighting Integration Notes for details. Temperature Control: Temperature control can be managed by schedules tied to house modes or by manual control based on time (Timed Temporary Hold, Temporary Hold and Permanent Hold). T HE YTH8320ZW1007/U DRIVER DOES NOT SUPPORT THE FOLLOWING FEATURES: Any feature not specifically noted as “supported” is not supported. Name Detection: All thermostats will populate during auto-discovery with their Z-Wave node number as their name. Thermostat names do not read into g! at this time. Remote Sensors: The YTH8320ZW1007/U thermostat does not support remote sensors.
2 of 13 INSTALLATION OVERVIEW 1. Install the YTH8320ZW1007/U thermostats and wire HVAC according to standard Honeywell YTH8320ZW1007/U documentation. 2. Test the thermostat and climate system to ensure that the thermostats correctly turn on the appropriate heating or cooling equipment, and open or close the appropriate valves / dampers. 3. Install a Leviton VRC0P-1LW (+3) RS-232 Z-Wave adapter in a location convenient for both a serial run to the g! Controller and within range of other Z-Wave devices. Note: Be sure that the “+3” notation is present on the back of the VRC0P-1LW. (See the Leviton application note for additional information: http://communities.leviton.com/docs/DOC-2392). 4. Run a Cat-5 or serial cable to the location of the Z-Wave RS-232 location. 5. Using a Primary Controller, such as a programming remote (ex. Leviton VRCPG), ControlThink’s ThinkEssentials or Leviton’s Vizia RF+ Installer Tool (v1.1.0.0) create a Z-Wave network and add thermostats and the RS-232 adapter according to standard procedures. Important! Disconnect the g! system from the VRC0P controller when any Z-Wave network configuration is occurring. 6. Connect the Serial Cabling to the Z-Wave RS-232 adapter electrically. See the wiring diagrams. 7. Configure g! for the thermostats and confirm communication between the thermostats and the g! controller. 8. Test the system by changing the set points, modes and schedules on the viewer and various thermostats, confirming that the various components in the system respond as expected. Z-W AVE REPEATERS Many Z-Wave devices function as repeaters, meaning an incoming signal can be passed to another Z- Wave device within range. The maximum distance a signal can be sent from one Z-Wave device to another varies depending on the brand/model of the device used. See the manufacturer’s documentation for the devices you intend to use for specifics. The signal can be extended from the controller to the device being controlled by a maximum of four passes, known as “hops.” (From the controller to the first device, the first device to the second, the second device to the third and from the third device to the one actually being sent the signal.) Depending on the network configuration, occasionally it may be necessary to manually program the “hops” to optimize reliability. Refer to the documentation that came with your specific programming tool for details. Note: Because Z-Wave door locks require repeaters that are “beaming-compatible” and that support beaming of encrypted signals we recommend using only repeaters (lamp modules, switches, etc.) that support these features if door locks will be a part of the installation. See the manufacturer’s documentation for the devices you intend to use for specifics. NOTES REGARDING THE TRACKING OF Z-WAVE DEVICES: In general g! keeps track of the states of all of the Z-Wave Network Devices; however there is latency in the reporting back of the devices from the Z-Wave network. The result is that g! updates its states as the devices report back. This is evident when watching the viewer interface after a change is made at the device. The viewer controls will update sequentially over a few seconds (or more on larger systems) as the devices report their states.
3 of 13 CONNECTION DIAGRAMS HC ControllerRS-232 Port 65Cat5 Cable 4DB9M to RJ45 Adapter 3DB9 to RJ11 Cable 2Leviton Z-Wave RS-232 Adapter 1Thermostats Z-Wave Signals 7Z-Wave Repeating Module B ILL OF MATERIALS Device Manufacturer Part Number Protocol Connector Type N otes1 Th e rmostat Hone yw e l l YTH8320ZW1007U Z‐Wave RF 2 Z‐Wave RS‐232A dapte r Le vi ton V RC0P‐1LW (+3) RS‐232/ Z‐Wave RJ‐11 Female 3RJ‐11 to DB9 Cable Leviton N/A RS‐232 RJ‐11 Ma l e / DB9 Female Included w/ VRC0P+3 4DB9 to RJ‐45 Adapter ELAN HA‐CB‐307 RJ‐45 Female x DB9 Ma l e 5Cat5 Cable Assembly Installer N/A RS‐232 RJ‐45Mal e x RJ‐45 Ma l e Mu s t terminate al l 8 conductors 6 Controller ELAN HCxx RS‐ 232 RJ‐45 Female Use Comm port 1, 2, 3, etc. 7Z‐Wave Re peating Module Various Various Z‐Wave RF Be ami ng and Encrypte d Signal Support Recommended Programming Remote Leviton VRCPG‐BSG Z‐Wave RF Not Shown ‐ Needed to set up Z‐Wave Network OR ControlThinks ThinkEssentials Leviton CTZUS‐1US Z‐Wave RF Not Shown ‐ Needed to set up Z‐Wave Network OR Vizia RF+ Installer Tool Le vi ton V RUSB‐1US Z‐Wave RF Not Shown ‐ Needed to set up Z‐Wave Network 8 Note: Update the VRC0P-1LW (+3) to the latest firmware prior to creating the Z-Wave network. Updates are found on the Leviton web site. http://www.leviton.com/OA_HTML/SectionDisplay.jsp?section=42159&minisite=10251 Minimum Version: $Leviton(C) 2008 V2.33S/Z-Wave 3.11
4 of 13 Z-WAVE NETWORK PROGRAMMING Program the Z-Wave according to standard procedures. Regardless of device function, the basic setup of Z-Wave networks is the same. Various limitations may be imposed based on the programming tool used. Refer to the documentation that came with your specific programming tool for details. Typically a Z-Wave network is programmed using its Programmer/Remote Control (such as the Leviton VRCPG-BSG remote, ThinkEssentials Software or Vizia RF+ Installer Tool) to enroll / include devices in the Z-Wave Network. The methods for using the VRCPG, ThinkEssentials and Vizia RF+ Installer Tool are detailed below. Note that these instructions assume you are familiar with Z-Wave programming concepts. If you require further detail or clarification, you may wish to see Leviton Vizia RF (www.ViziaRF.com), or Honeywell YTH8320ZW1007/U documentation / technical support for assistance. Important! Programming using the Leviton VRCPG-BSG Remote is NOT supported for thermostats when Z-Wave locks are to be included in the system. While the VRCPG-BSG does allow you to enroll locks in a Z-Wave network it does not allow you to associate the locks with the VRC0P module. P ROGRAMMING USING THE LEVITON VRCPG-BSG REMOTE: Setup steps below are created using a VRCPG-BSG remote. Your steps may vary somewhat if your remote model differs, but the basic process should be the same. 1. Confirm all devices are at factory default and have not been setup in any Z-Wave Network. 2. To include the YTH8320ZW1007/U thermostats in the network: a. Start up the Leviton Remote and begin the Installation Checklist. i. Perform Step 1 of the Installation Checklist, Include Dimmers/Switches, and include the first thermostat in the network. ii. When prompted by the remote, on the YTH8320ZW1007/U thermostat: 1. Press the System button. 2. Press and hold the two buttons indicated below until the display changes. 3. Use the center up and down arrows to navigate to setup function rf10. 4. Use the right up and down arrows to change the setting to 1. 5. Wait until the thermostat confirms its inclusion into the Z-Wave network. 6. Select “Done” to exit the set up menu. Note: It is best practice to give the thermostat a descriptive name when prompted, like Master Bedroom, for future reference. Note that this name is not saved in the thermostat and will not be automatically read
5 of 13 into g! You should keep notes of the location of each thermostat and their Node IDs, as the only identification available to g! is the Node ID. 3. Repeat Step 2 for each additional YTH8320ZW1007/U to be added to the network. 4. To include the VRC0P-1LW (+3) in the network: a. Set the VRC0P-1LW to programming mode by pressing and holding the button (clear tab on face of unit) until the light blinks amber. b. Perform Step 2 of the Installation Checklist, Include Controller, to include all Controllers into the network. Controllers include the RS-232 interface module (VRC0P-1LW (+3)). 5. Perform Step 3 of the Installation Checklist, Update Controller, to update all of the controllers following the inclusion of all devices. This will create the proper mapping between devices. 6. In a thermostat only network, you may skip Step 4 (Create Areas) and go to Step 5 (Set Associations) of the Installation Checklist. 7. Perform Step 5 of the Install Checklist, Set Associations, to associate each thermostat with the controller. 8. You may complete or skip Step 6 (Security) of the Installation Checklist as desired. 9. Choose Step 7 of the Installation Checklist, Install Complete. 10. Test all devices for proper operation. From the Main Menu of the VRCPG remote you should be able to select Thermostats and get current temperature data and change modes (heat, cool etc.) for each thermostat on your network. P ROGRAMMING USING THINKESSENTIALS AND USB Z-WAVE ADAPTER: Setup steps below are created from version 2.5 of ThinkEssentials. If you are running a different version, your steps may be somewhat different than below, but the basic process is the same. 1. Confirm all devices are at factory default and have not been setup in any Z-Wave Network. 2. Either create a New Network or Open an Existing Network file. 3. To include the YTH8320ZW1007/U thermostats in the network: a. In the ThinkEssentials software, from the Design Tab select the Add Device button. b. On the YTH8320ZW1007/U thermostat: i. Press the System button. ii. Press and hold the two buttons indicated below until the display changes. iii. Use the center up and down arrows to navigate to setup function rf10.
6 of 13 iv. Use the right up and down arrows to change the setting to 1. v. Wait until the thermostat confirms its inclusion into the Z-Wave network. vi. Select “Done” to exit the set up menu. 4. Repeat Step 3 for each additional YTH8320ZW1007/U to be added to the network. 5. To include the VRC0P-1LW in the network: a. Set the VRC0P-1LW (+3) to programming mode by pressing and holding the button (clear tab on face of unit) until the light blinks amber. b. In the ThinkEssentials software, from the Design Tab select the Add Device button. The software will confirm the VRC0P-1LW has been included in the network and its icon will be displayed in the Design Tab. The software will automatically assign a Node ID during this process. Note: It is best practice to give the thermostat a descriptive name when prompted, like Master Bedroom, for future reference. Note that this name is not saved in the thermostat and will not be automatically read into g! You should keep notes of the location of each thermostat and their Node IDs, as the only identification available to g! is the Node ID. 6. Associate each thermostat to the Controller. a. Move to within three feet of the thermostat. b. Right-click on the Thermostat icon and select “Properties”; in the lower right-hand corner of the display, the status message “Loading status from the device” appears; wait until the status message changes to “Done loading status.” c. Switch to the “Device Associations” tab. d. Select “Button #1” in the drop down menu. e. Press the “Edit” button – a pop up appears. f. Left-click on the Controller icon to make the association, then click on “Done” in the pop up. 7. Test all devices for proper operation. From the Design Tab you should be able to right-click on each thermostat and choose Advanced Thermostat Options to see current temperature data and change modes (heat, cool, etc.) for each thermostat on your network. P ROGRAMMING USING LEVITON’S VIZIA RF+ INSTALLER TOOL (V1.1.0.0) AND USB Z-WAVE ADAPTER: Setup steps below are created from version 1.1.0.0 of the Vizia RF+ Installer Tool. If you are running a different version, your steps may be somewhat different than below, but the basic process is the same. 1. Confirm all devices to be added are at factory default and have not been setup in any Z- Wave Network. 2. Either create a New Network or Open an Existing Network file.
7 of 13 3. To include the YTH8320ZW1007/U thermostats in the network: a. In the Vizia RF+ software select the Include Device button. b. On the YTH8320ZW1007/U thermostat: i. Press the System button. ii. Press and hold the two buttons indicated below until the display changes.
8 of 13 iii. Use the center up and down arrows to navigate to setup function rf10. iv. Use the right up and down arrows to change the setting to 1. v. Wait until the thermostat confirms its inclusion into the Z-Wave network. vi. Select “Done” to exit the set up menu. 4. Repeat Step 3 for each additional YTH8320ZW1007/U to be added to the network. 5. To include the VRC0P-1LW (+3) in the network: a. Set the VRC0P-1LW to programming mode by pressing and holding the button (clear tab on face of unit) until the light blinks amber. b. In the Vizia RF+ software select the Include Device button. The software will confirm the VRC0P-1LW has been included in the network and it will be displayed in the All Devices node of the programming tree. The software will automatically assign a Node ID during this process. Note: It is best practice to assign the thermostat a descriptive name, like Master Bedroom, for future reference. Note that this name is not saved in the thermostat and will not be automatically read into g! You should keep notes of the location of each thermostat and their Node IDs, as the only identification available to g! is the Node ID. 6. Associate each thermostat to the Controller. a. In the Vizia RF+ software right click on the VRC0P module under All Devices in the programming tree. b. Select RS-232 Setup from the menu. c. In the LevSerialInterfaceConfig dialog box: i. Verify that the RS-232 Module drop down shows that the VRC0P module is selected. ii. Check the box for each thermostat Node ID to be associated to the VRC0P module. iii. Click the Set Association button. iv. Close the dialog box. 7. Test all devices for proper operation. Select each thermostat from the All Devices node of the programming tree and change modes (heat, cool, fan, etc.) for each thermostat on your network.
9 of 13 g! C ONFIGURATION D ETAILS The following table provides settings used in the g! Configurator when connecting to a Z-Wave thermostat network. Please refer to the Configurator Reference Guide for more details. In the table below: o “” Select the appropriate item from the list (or drop-down) in the Configurator. o “”, etc. Type in the desired name for the item. o “”, etc. The system will auto detect this variable. Devices Variable Name Setting Communication De vi ce Name (Default: New Device) Type Se ri al Port Communication Type Le viton Z‐Wave RS‐232 Network Location (Not Required) Comm Port HVAC Units Name Model Generic HVAC Unit Controls He at Controls Cooling Controls Fan Thermostats Name Editable Location (Not Required) Comm De vice The rmostat # He ati ng Unit Cooling Unit Schedules Global Options Units Te mporary Hol d Mode Te mporay Hol d De faul t Time Outside Te mpe rature Sensor Outside Humidi ty Sensor Set up HVAC Schedules Under Each T‐StatClick the Di scove r De vi ce sbutton on the Communication Devi ce Set to YES if controlling Fan Di scove r Devices will set a Defaul t name of Z‐Wave The rmostat #1, #2, etc. Set to YES if controlling He at Com 1, 2, 3 etc. Choose Optional sensor if installed or choose internet Fahrenheit or Celsius Choose Optional sensor if installed or choose internet Ti me d Hol d or Hol d until next schedule period Set to YES if controlling Cooling Comments
10 of 13 TESTING THE Z-WAVE SYSTEM On occasion it may be necessary to test the Z-Wave system “outside” of the g! interface to verify communication between the thermostats and the controller (the VRC0P-1LW). The following steps are intended to provide a method to test the basic communication status of the Z-Wave network. 1. Complete your Z-Wave network set-up as described above, ensuring all thermostats and controllers have been added to the network. 2. Connect a serial cable from your computer to the VRC0P-1LW’s RJ-11 to DB9 cable. Use a USB to Serial adapter if required. 3. Set up a terminal program (ex: HyperTerminal) with the following settings: a. 9600 baud; 8 data bits; No parity; 1 stop bit; Flow Control – None b. ASCII Sending Set Up i. Send line ends with line feeds ii. Echo typed characters locally 4. Send test commands to verify correct operation: Note: Terminal programs other than HyperTerminal may display differently. The important thing is that the “