Honeywell Yth8320zw1007u Manual
Here you can view all the pages of manual Honeywell Yth8320zw1007u Manual. The Honeywell manuals for Thermostat are available online for free. You can easily download all the documents as PDF.
Page 1
ELAN Home Systems ● 1690 Corporate Circle ● Petaluma, CA 94954 USA tech support: 800.622.3526 • main: 760.710.0990 • sales: 877.289.3526 • email: [email protected] ©2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners. Integration Note Manufacturer: Honeywell Model Number(s): YTH8320ZW1007/U Thermostats / Leviton VRC0P-1LW (+3) RS-232 Adapter Minimum Core Module Version: g! 5.8 Document...
Page 2
2 of 13 INSTALLATION OVERVIEW 1. Install the YTH8320ZW1007/U thermostats and wire HVAC according to standard Honeywell YTH8320ZW1007/U documentation. 2. Test the thermostat and climate system to ensure that the thermostats correctly turn on the appropriate heating or cooling equipment, and open or close the appropriate valves / dampers. 3. Install a Leviton VRC0P-1LW (+3) RS-232 Z-Wave adapter in a location convenient for both a serial run to the g! Controller and within range of other Z-Wave...
Page 3
3 of 13 CONNECTION DIAGRAMS HC ControllerRS-232 Port 65Cat5 Cable 4DB9M to RJ45 Adapter 3DB9 to RJ11 Cable 2Leviton Z-Wave RS-232 Adapter 1Thermostats Z-Wave Signals 7Z-Wave Repeating Module B ILL OF MATERIALS Device Manufacturer Part Number Protocol Connector Type N otes1 Th e rmostat Hone yw e l l YTH8320ZW1007U Z‐Wave RF 2 Z‐Wave RS‐232A dapte r Le vi ton V RC0P‐1LW (+3) RS‐232/ Z‐Wave RJ‐11 Female 3RJ‐11 to DB9 Cable Leviton N/A RS‐232 RJ‐11 Ma l e / DB9 Female Included w/ VRC0P+3 4DB9 to RJ‐45...
Page 4
4 of 13 Z-WAVE NETWORK PROGRAMMING Program the Z-Wave according to standard procedures. Regardless of device function, the basic setup of Z-Wave networks is the same. Various limitations may be imposed based on the programming tool used. Refer to the documentation that came with your specific programming tool for details. Typically a Z-Wave network is programmed using its Programmer/Remote Control (such as the Leviton VRCPG-BSG remote, ThinkEssentials Software or Vizia RF+ Installer Tool) to...
Page 5
5 of 13 into g! You should keep notes of the location of each thermostat and their Node IDs, as the only identification available to g! is the Node ID. 3. Repeat Step 2 for each additional YTH8320ZW1007/U to be added to the network. 4. To include the VRC0P-1LW (+3) in the network: a. Set the VRC0P-1LW to programming mode by pressing and holding the button (clear tab on face of unit) until the light blinks amber. b. Perform Step 2 of the Installation Checklist, Include Controller, to include...
Page 6
6 of 13 iv. Use the right up and down arrows to change the setting to 1. v. Wait until the thermostat confirms its inclusion into the Z-Wave network. vi. Select “Done” to exit the set up menu. 4. Repeat Step 3 for each additional YTH8320ZW1007/U to be added to the network. 5. To include the VRC0P-1LW in the network: a. Set the VRC0P-1LW (+3) to programming mode by pressing and holding the button (clear tab on face of unit) until the light blinks amber. b. In the ThinkEssentials software,...
Page 7
7 of 13 3. To include the YTH8320ZW1007/U thermostats in the network: a. In the Vizia RF+ software select the Include Device button. b. On the YTH8320ZW1007/U thermostat: i. Press the System button. ii. Press and hold the two buttons indicated below until the display changes.
Page 8
8 of 13 iii. Use the center up and down arrows to navigate to setup function rf10. iv. Use the right up and down arrows to change the setting to 1. v. Wait until the thermostat confirms its inclusion into the Z-Wave network. vi. Select “Done” to exit the set up menu. 4. Repeat Step 3 for each additional YTH8320ZW1007/U to be added to the network. 5. To include the VRC0P-1LW (+3) in the network: a. Set the VRC0P-1LW to programming mode by pressing and holding the button (clear tab on face...
Page 9
9 of 13 g! C ONFIGURATION D ETAILS The following table provides settings used in the g! Configurator when connecting to a Z-Wave thermostat network. Please refer to the Configurator Reference Guide for more details. In the table below: o “” Select the appropriate item from the list (or drop-down) in the Configurator. o “”, etc. Type in the desired name for the item. o “”, etc. The system will auto detect this variable. Devices Variable Name Setting Communication De vi ce...
Page 10
10 of 13 TESTING THE Z-WAVE SYSTEM On occasion it may be necessary to test the Z-Wave system “outside” of the g! interface to verify communication between the thermostats and the controller (the VRC0P-1LW). The following steps are intended to provide a method to test the basic communication status of the Z-Wave network. 1. Complete your Z-Wave network set-up as described above, ensuring all thermostats and controllers have been added to the network. 2. Connect a serial cable from your computer...