Page 81
5 - 9 Network Configuration There are several networking options available for the Thor VX9. 802.11 Wireless Radios Please refer to the instructions for configuring the 802.11 radio. Different utilities are used depending on the tyep of radio car installed: Laird Connection Manager (page 6-1) uses an 802.11 a/b/g/n radio Summit Client Utility (page 6-35) uses an 802.11 a/b/g/n radio Atheros Client Utility (page 6-72) uses an 802.11 a/b/g radio Broadcom Wireless Utility (page 6-83) uses an 802.11 b/g...
Page 82
5 - 10 VMT Manager The VMT Manager is used to configure many of the Thor VX9 options. If using Classic view for the control panel, click on the VMT Manager icon. If using Category view for the control panel, click on Other Control Panel Options and then the VMT Manager icon to launch the VMT Manager application. Main Tab The Main tab shows the embedded controller’s firmware version and build date as well as the Thor VX9 computer manager application version and build date. There are no user configurable...
Page 83
5 - 11 General Settings Tab The General Settings tab provides configuration options for the COM1, COM2 and Multipurpose Connector ports, Startup and Shutdown options and configuration of the optional defroster. After making any desired changes, click Apply to apply the new changes or OK to apply the changes and dismiss the VMT Manager screen. COM1 Power Enable 5VDC power on COM1 pin 9 to power external 5V devices with a maximum power consumption of 2.5W, 500mA. If you want the external device to be...
Page 84
5 - 12 COM2 Power Enable 12VDC power on COM2 pin 9 to power external 12V devices with a maximum power consumption of 6W, 500mA. Options are the same as for COM1. Only COM1 should be used for connecting serial bar code scanners. Multi Purpose Connector Enable 12VDC power on Multi Purpose Connector COM4 pin 9 to power external 12V devices. Same power consump- tion and options as COM2. Only COM1 should be used for connecting serial bar code scanners. COM4 is enabled by default but can be de-selected if...
Page 85
5 - 13 UPS Tab The UPS tab contains options for the UPS battery in the Thor VX9. After making any desired changes, click Apply to apply the new changes or OK to apply the changes and dismiss the VMT Manager screen. If prompted, click Yes to confirm your changes. UPS Battery Enable/disable the internal UPS battery. The UPS battery protects the Thor VX9 from being shutdown if there’s a loss of input power. Configuration Configure how the Thor VX9 should react when/if the input power is lost by enabling...
Page 87
5 - 15 Display Backlight Tab The Display Backlight tab contains options and status for the display backlight. After making any desired changes, click Apply to apply the new changes or OK to apply the changes and dismiss the VMT Manager screen. If prompted, click Yes to confirm your changes. Blackout-screen Input Signal Enable Blackout (Screen Blanking) screen functionality. When enabled, the backlight will turn off if there’s a connection between pin 5 and 6 in the input power connector (yellow and...
Page 88
5 - 16 Light Sensor Enable the light sensor on the front panel, which will automatically increase or reduce the display backlight when nec- essary. Enable lower sensitivity if a smoother behavior is needed. Backlight Intensity Monitor backlight intensity 0-100%.
Page 89
5 - 17 Advanced Tab The Advanced tab provides monitoring for several advanced functions. There are no user configurable options on this tab. On the Advanced tab you can: Monitor the latest POST code sent from the CPU Module BIOS. Monitor driver independent touch panel functionality Monitor the internal temperature at carrier board level. Monitor input and battery power.
Page 90
5 - 18 Freefloat Access*One TE (Optional) Access*One terminal emulation software is available on the Thor VX9. A pdf User’s Manual for Access*One is included as part of the installation at C:\Program Files\Freefloat\Freefloat Access One. Refer to this manual or to Freefloat.com for infor mation on configuring and using Access*One.. Freefloat WLinq Wedge WLinq bar code decoder configuration software is installed on the Thor VX9. Freefloat WLinq includes Help available by select- ing Start > All...