Security Sy stem Operat ion (Contd) 21 SCREEN ACTION 3. The User Authorization screen is displayed with the instructions To Clear Bypasses, Enter Code. Note: A zone cannot be unbypassed while the system is armed. Enter your 4-digit user code. The More Choices screen is displayed showing the system as Ready to Arm . Note: This will not occur if any zone(s) is open (not ready).
Security Sy stem Operat ion (contd) 22 How to Disarm the System IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the 6270 will beep rapidly upon entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. Disarm the system as follows: SCREEN ACTION 1. Press the DISARM button on any Armed screen. The User Authorization screen is displayed with the instructions “ To Disarm, Enter Code ” . 2. Enter your 4-digit user code. The system will disarm. If you have access to multiple partitions, the Partition No. & Description screen is displayed.
Security Sy stem Operat ion (Contd) 23 SCREEN ACTION 3. Press the DISARM ALL button if you wish to disarm the system. The 6270 beeps once and the Arming screen is displayed showing the system as Ready to Arm or not ready if any zone is faulted (open). Note: If you wish to disarm only selected partitions, you must first highlight the partition(s) to be disarmed, then press the DISARM SELECTED button. The 6270 beeps once and the Arming screen is displayed showing the system as Ready to Arm or not ready if any zone is faulted (open). Note: Once the system is disarmed, the 6270 will return to the Home screen after the selected “To Home Page After ” time has expired. This time is selected on the “Setup ” screen.
Security Sy stem Operat ion (contd) 24 How to Check the Status of Other Partitions This system supports between one and eight Partitions (as configured by your installer.) Partitioning enables a single physical alarm system to control up to eight areas of protection (partitions) depending on the system you have purchased. Each 6270 and other keypad is assigned a default partition for display purposes, and will show only that partitions information. For example, if your physical site is a four-apartment housing unit, your alarm system may be configured with four partitions. Each apartment ’s zones (door, windows, smoke detectors, etc.) are assigned to separate partitions, giving each apartment independent arming/disarming control of its own partition (area). A landlord or manager may be granted access to all partitions, so he/she can control the entire system. If a user is so authorized, a 6270 or other keypad in one partition can be used to perform system functions in another partition. (Note that only those partitions authorized and programmed by the installer can be accessed in this manner.) To check the status of other partitions perform the following: SCREEN ACTION 1. From the Home screen press the SECURITY button to display the Arming screen.
Security Sy stem Operat ion (Contd) 25 SCREEN ACTION 2. Press the Current Partition tab (lower edge of the screen; in this case it displays P1 ). The User Authorization screen is displayed with the instructions “ For Authorized Partitions, Enter Code ” . 3. Enter the code authorized to access other partition(s). If the code is accepted, the system displays the partitions that user has access to. Note: A code may have access to some (but not all) of the available partitions. This screen displays the available partitions (in this case, Partitions 1, 2, and 3), and their current status. The current partition is shown at the top of the display (in this example, the device is attached to Partition 1 ( P1)). To change this assignment, select the appropriate button (e.g. press P2 to switch control to Partition 2).
Security Sy stem Operat ion (contd) 26 How to Send Emergency Messages x Emergency messages are optional and may not be available on your system. Ask your system installer if emergency messages are available on your system. x The Emergency screen cannot be accessed while running a diagnostic test. An emergency message for panic or fire can be sent to the central monitoring station from the Emergency screen. The Emergency screen can be accessed by activating the PANIC button located below the screen. Once the Emergency screen is accessed, perform the following to send an emergency message. SCREEN ACTION On the Emergency screen press and hold (for at least 2 seconds) the associated alarm button for the type of emergency message you want to send ( FIRE, PANIC, or MEDICAL ). When the message is sent, the associated Message Sent statement is displayed in the text box to the right of the buttons. You are immediately returned to the screen from which you pressed the “PANIC ” button.
Security Sy stem Operat ion (Contd) 27 How to View the Event Log Your system has the ability to record various events in a history log wherein each event is recorded with the time and date of its occurrence. The control panel must be programmed to record various system events in installer programming mode. To view the Event Log, perform the following: SCREEN ACTION 1. From the Home screen, press the SECURITY button. The Arming screen is displayed. 2. From the Arming screen press the MORE CHOICES button. The More Choices screen is displayed.
Security Sy stem Operat ion (contd) 28 SCREEN ACTION 3. Press the EVENT LOGS button on the More Choices screen. The Event Log screen is displayed. Note: While 6270 is requesting and receiving the event log data from the control panel, the Event Log screen displays Please Wait! . To view additional events, press the up/down arrows to scroll through the event log. To view all items, press the Show More button. Note: When All Partitions or All Events button is pressed, and more than 100 events exist, the Show More button text will change to read Next 100.
29 Fire Alarm System Operatio n Introduction to Fire Alarm System Operation Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency, the installed smoke and heat detectors will automatically send signals to your Control/Communicator, triggering a loud interrupting sound from the keypad. An interrupted sound will also be produced by optional exterior sounders. A FIRE message will appear at your keypad and remain on until you silence the alarm. In Case of Fire Alarm 1. Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest keypad and manually initiate an alarm by pressing the panic key assigned as FIRE emergency (if programmed by the installer) and hold down for at least 2 seconds. 2. Evacuate all occupants from the premises. 3. If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately. Silencing a Fire Alarm 1. Silence the alarm by entering your code and pressing the OFF key. To clear the alarm from the display, enter your code and press the OFF key again. 2. If the keypad does not indicate a READY condition after the second OFF sequence, press the READY key to display the zone(s) that are faulted. Be sure to check that smoke detectors are not responding to smoke or heat producing objects in their vicinity. In this case, eliminate the source of heat or smoke. 3. If this does not remedy the problem, there may still be smoke in the detector. Clear it by fanning the detector for about 30 seconds. 4. When the problem has been corrected, clear the display by entering your code and pressing the OFF key.
Fire Al arm System Oper ation (cont d) 30 Fire Display Lock If several zones produce an alarm before any are silenced, all zones in alarm will scroll. The system can be programmed to lock the keypad display with the first zone that produced an alarm. Ask your installer if your system has been activated with this feature. To display the other zone(s), press the [ ✴ ] key for each zone. Also the “ A”, “ B” , or “ C” key may be programmed to scroll the keypad display to view the previous or subsequent fire alarms.