    Have a look at the manual Honeywell Sundial RF Pack 5 Wireless Enabled 2 Zone Programmer and Thermostats User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							31 
    						
    							33 
    						
    							34
    CONFIGURATION & SERVICE DATA
    Configuration Data (to be completed by Installer)
    The tables below are for the Installer to complete to indicate how your ST9520C and 
    DT92E have been configured.
    Application
    Insert application number as per Installation wiring diagrams:
    Configurable FeaturesOptionsFactory 
    settingInstaller configured 
    (tick box or note value)
    ST9520C Configuration - standard
    24hr or am/pm clock 
    display. am/pm display
    24hr display
    Display backlight operation. Off
    on if button pressed
    on continuously
    Automatic time change.disabled,
    enabled
    1-day or 5/2-day or 7-day 
    operation.1-day operation
    5/2-day operation
    7-day operation
    Number of ON/OFFs per 
    day.2 on/offs per day,
    3 on/offs per day
    Default time programme.
    A = standardb = at home
    C = economy
    Hot water set temperature From 40 to 85°C60°CNot used in this system
    Optimum start no optimum start
    delayed start
    optimum start on
    Optimum start limit 1 hour
    2 hours
    3 hours
    Optimum stop disabled
    enabled
    Frost protection temperature From 5 to 16°C5°C
    Minimum ON/OFF time 1, 2, 3, 4, 5 minutes1 minute
    Cycle rate 3, 6, 9, 12 cycles 
    per hour6 cycles
    Proportional band width From 1.5 to 3.0°C1.5°C
    Failsafe mode (loss of RF 
    communications) off
    on 20%
    ST9520C Configuration - OpenTherm
    OpenTherm disabled
    enabled
    Heating Limit temperature 90°C
    Low load operation disabled
    enabled
    50047645-006 A 
    						