Home > Honeywell > Thermostat > Honeywell Sundial RF Pack 5 Wireless Enabled 2 Zone Programmer and Thermostats User Manual

Honeywell Sundial RF Pack 5 Wireless Enabled 2 Zone Programmer and Thermostats User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell Sundial RF Pack 5 Wireless Enabled 2 Zone Programmer and Thermostats User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							21
    DT92E OPERATING INDICATORS
    Low Battery Indicator / Battery Replacement
    The battery symbol will start 
    to flash if the battery power is 
    running low. From this point, 
    there will be a minimum of 4 
    weeks before the product will 
    cease to function.
    Batteries are accessed by 
    unclipping the front cover at the 
    bottom. Note battery polarity. 
    Reverse process to refit front 
    cover.
    Use 2xLR6 (AA) alkaline 
    batteries only. 
    Immediately on power up, DT92E will try to communicate and synchronise with 
    ST9520C. This process may take up to 4 minutes, and will be indicated by the word 
    ‘Sync’ on the DT92E display.
    RF Communications Indicator
    A brief flash of the RF symbol  indicates the DT92E 
    has been communicating with the other system 
    controls.
    Lockout
    Your DT92E works in conjunction with the ST9520C 
    time control. If the timer is set to OFF or CONT it may 
    not be possible to override it from the thermostat 
    and this is indicated by the lockout symbol 
    . To 
    switch the heating on you must go to the timer and 
    set the Mode to AUTO, ONCE, or CONT.
    2 x LR6 AA Alkaline
    1
    2 
    						
    							22
    DT92E ENERGY SAVING ECO FEATURE
    The ECO button allows you to change to a lower, energy saving set temperature for 
    a period of your choice, from 1 to 24 hours. This temperature is pre-set in the DT92E 
    Installer Mode, but you can adjust this to any temperature you want when ECO mode 
    has been activated. The default ECO temperature is 18°C.
    At the end of the time period, the thermostat will return to its original set 
    temperature.
    Entering ECO Mode and Setting 
    the Energy Saving Time Period
    Press the green ECO button to enter ECO 
    mode. The word ECO will appear on the 
    display and the thermostat will allow you to 
    set the number of hours you want to be at 
    the new set temperature.
    Use the 
     and  buttons to set the hours, 
    up to a maximum of 24 hours.
    Please note – ECO mode is not accessible 
    in Holiday mode or if Service shutdown 
    has occurred.
    What Happens in ECO Mode?
    In ECO mode, the display will show a 
    countdown of the remaining time (hours 
    and minutes) in ECO mode, identified by 
    the hourglass symbol. The display will 
    alternate every 5 seconds to show the 
    current room temperature.
    When in ECO mode, pressing the 
     or  
    buttons will adjust the set temperature for 
    the remainder of the ECO time period. 
    5 s 5 s
    5 s
    1,2,3,4....,24hr 
    						
    							23
    DT92E ENERGY SAVING ECO FEATURE
    FINE TUNING YOUR  DT92E
    Changing the DT92E Installer Parameters
    The DT92E has a special Installer Mode where some features can be adjusted to suit 
    your lifestyle or preferences – these are called Installer Parameters, and are listed in 
    the table below, along with a description of the options that are possible.
    Your installer should set this up for you to suit your application (see \
    CONFIGURATION 
    & SERVICE DATA section). However, you may wish to alter some of the settings 
    yourself, and this section shows you how to do this.
    INSTALLER 
    PARAMETERParameter
    Default 
    Value Options
    Description
    Temperature 
    measurement offset t0
    0-3 to 3 K Offset to measured 
    temperature
    Upper setpoint limit uL3521 to 
    35°C Upper set temperature 
    limit in °C
    Lower setpoint limit LL55 to 21°C Lower set temperature 
    limit in °C
    Energy saving ECO 
    setpoint ES
    185 to 35°C Energy saving ECO set 
    temperature in °C
    Reset parameters 
    to factory settings FS
    10, 1Parameter will be set to 0 
    if any of the other param-
    eter values have been 
    changed. Set to 1 to get 
    back to factory settings.
    How to Exit ECO Mode
    To exit ECO mode, simply press the green 
    ECO button again. ECO will disappear 
    from the display and the thermostat will 
    control to its previous set temperature. 
    						
    							24
    To Enter Installer Mode:
    a. Hold the 
     button for 2 seconds until DT92E is in standby mode.
    b. Hold 
     and  buttons for 3 seconds until the word ‘Inst’ appears on the 
    display.
    c.  Press the 
     button.
    The first parameter is now ready to be changed.
    To Select a Parameter:
    Use the 
     and  buttons to move from one parameter 
    to the next. Stop at the Parameter you wish to change.
    To Change a Parameter:
    Use the standby button to select the parameter value, then the 
     and  buttons to 
    change the value. Confirm the change by pressing the  button again to take you 
    back to the parameter.
    To Exit Installer Mode:
    Hold the 
     button for 3 
    seconds to exit Installer 
    Mode.
    Note: The Installer Mode will 
    exit automatically after 10 
    minutes if  no adjustments 
    have been made in this 
    time.
    FINE TUNING YOUR  DT92E
    3 s
    3 s
    2 s 
    						
    							25
    BDR91T Controls Layout
    Automatic Operation
    The BDR91T relay box simply switches the boiler 
    on and off according to a wireless signal it receives 
    from the ST9520C. It is mainly used when the boiler 
    is installed  in a remote location where it may be 
    difficult to run wires direct from the timer. The green 
    light indicates the status of the relay output:
    Green light on = relay on
    Green light off = relay off
    Temporary Manual Override
    In normal operation it should not be necessary to 
    interact with the BDR91T. However it is possible 
    to press the button and temporarily override the 
    current relay position. This will be cancelled as soon 
    as the Relay Box receives another signal from the 
    ST9520C, because automatic operation has a higher 
    priority than manual operation.
    Loss of Wireless Communications
    If the RF communication is lost for a period of 1 hour the red light will illuminate.
    The Relay Box will then enter the failsafe mode as selected by your Installer (see 
    page 31).
    When RF communication is restored, the Relay Box will automatically return to 
    normal operation.
    OPERATING YOUR BDR91T RELAY BOX (IF INSTALLED)
    Green LED
    Red LED
    Push button
    Green light, relay status indicator
    Push button
    Red light, indicator for special modes 
    or loss of communications 
    						
    							26
    How do I set the time only, if the ST9520C clock is not correct?
    Your ST9520C contains an accurate digital clock that is factory set. Should you ever 
    need to change the time, just follow this procedure:
    a. Move the slider to the DAY/TIME position.
    b.  Keep pressing the green 
     button until the message ‘SET THE TIME’ is 
    displayed. To change the time, press the   or  buttons until the correct 
    time is shown. The message ‘IS TIME OK?’ will be displayed. Press the green  
    button to confirm the time is correct.  If you have made a change, the message 
    ‘TIME SAVED’ will show, followed quickly by ‘DATE + TIME COMPLETE’.
    c.  Move the slider to the RUN  position, to complete changing the time.
    What do I do when the clocks go back in October and forward 
    in March?
    Your ST9520C is factory set to change the clock automatically at the correct dates, 
    so you should never need to adjust the clock forward or backwards yourself. It is 
    possible to disable this particular feature, as described in the section ‘Changing the 
    Installer Parameters’ (page 15). You may also check the section ‘Configuration 
    & Service Data’ (page 34) to see how your Installer has configured your product.
    What should I do if I get ‘lost’ while programming the ST9520C?
    The LoT™ Display on ST9520C will provide you with help and tips to work through 
    the programming. Should you ever get ‘lost’, the simplest thing to do is\
     to move the 
    slider to the RUN position, and then move it back to the appropriate programming 
    position where you got lost. At this point just follow the instructions again.
    What happens if there is a power failure?
    In the event of a mains power failure, the ST9520C display will go blank, the 
    indicator lamps will go out, and the control outputs will switch off. The real time 
    will be constantly maintained by means of the built-in battery backup, ready to 
    power back up as if nothing had happened when the mains power is restored. In 
    addition, all programmes and settings are stored in a special memory (called Non 
    Volatile  memory) which requires no power to maintain information so will be retained 
    indefinitely.
    Should the correct time and date ever be lost, for whatever reason, the message ‘SET 
    DATE + TIME’ will be displayed whilst the slider is in the RUN  position. In this case, 
    simply follow the procedure described under ‘Step 1: Setting the Date & Time’ 
    (page 6). It should not be necessary to make any changes to your programmes.
    FAQ  AND TROUBLESHOOTING 
    						
    							27
    How reliable is 2-way RF communication?
    The 2-way RF communication (also known as wireless communication) used by 
    Honeywell is extremely robust and reliable. When installed correctly the Signal 
    Strength test feature allows the Installer to locate the system components where 
    mutual signal reception is strong. During communication, signals are sent several 
    times to ensure receipt, and if any message is garbled, the error detection software 
    recognises this and ensures the message is repeated again.
    What do I do if RF communication is lost?
    Follow the steps in the Troubleshooting Guide on the next page. The most likely 
    cause for loss of communications is the DT92E batteries running low on p\
    ower. This 
    will be indicated on the DT92E display by a flashing battery symbol, or the display 
    may even be blank. Simply replace the batteries (as shown on page 21) and wait a 
    few minutes for communications to become re-established.
    If this does not resolve the problem it may be that the RF signal path between 
    the ST9520C and the DT92E is blocked by a metal object. Check the direct path 
    between the two devices and reposition any object that may be blocking the signal, 
    or move the thermostat.
    How do I know when to change the batteries in the DT92E 
    room thermostat?
    If the DT92E batteries need changing, the battery symbol will flash on the DT92E 
    display. DT92E will continue to operate for at least 4 weeks after the indicator 
    begins to flash. The ST9520C will also show the message ‘SENSOR LOW\
     BATT’ 
    and the appropriate radiator symbol 
     will flash for either Zone 1 or Zone 2. It 
    is important to change the DT92E batteries as soon as the low battery condition is 
    indicated, as reduced battery power may affect the RF signal strength and impair 
    RF communications.
    FAQ  AND TROUBLESHOOTING 
    						
    							28
    Troubleshooting Guide
    This is a quick guide to help you diagnose and cope with possible problems with 
    your wireless control system. For further assistance, please contact your Installer.
    SymptomPossible CauseRemedy
    ST9520C has a blank LCD 
    display No power to the 
    heating system.Check that there is power to the 
    heating system.
    Fault in ST9520C
    Call Installer
    ST9520C indicates that 
    Heating Zones are ON, but 
    radiators are cold
    Temperature controls 
    are switched off or 
    set too low.Check that the temperature 
    controls in the system are set to 
    appropriate levels.
    Boiler or other 
    system controls 
    have malfunctioned. Call Installer
    ST9520C shows the 
    message: 
    ‘INTERNAL FAULT’ Fault in ST9520C
    Call Installer
    Every few seconds, the 
    ST9520C screen shows the 
    message:  ST9520C is 
    counting down the 
    number of days 
    until your next boiler 
    service is due.Arrange a boiler service before 
    the counter reaches zero.
    After servicing your boiler, the 
    Service Engineer / Installer will 
    reset the ST9520C to remind 
    you when the next boiler service 
    is due. Each service is normally 
    a maximum of 1 year apart.
    Although the heating is still 
    operating, the ST9520C 
    screen keeps flashing the 
    message:Your boiler service 
    is overdue.
    Arrange an immediate boiler 
    service.
    After servicing your boiler, the 
    Service Engineer / Installer will 
    reset the ST9520C to remind 
    you when the next boiler service 
    is due. Each service is normally 
    a maximum of 1 year apart.
    Can I override the Programmer from the DT92E thermostat?
    As well as changing the set temperature from the DT92E, it is also possible to override 
    the heating system on or off from the DT92E.  This is only possible if the ST9520C 
    is in AUTO or ONCE Modes. If ST9520C is in CONT mode it will not be poss\
    ible to 
    switch the heating off from the DT92E. Similarly, if ST9520C is in OFF mode, it will 
    not be possible to switch the heating on from the DT92E. If these latter overrides are 
    required it is first necessary to change the ST9520C mode setting to AUTO or ONCE.
    FAQ  AND TROUBLESHOOTING 
    						
    							29
    SymptomPossible CauseRemedy
    The ST9520C screen shows 
    the message: Your boiler service 
    is overdue and 
    the boiler has 
    been automatically 
    switched off to 
    ensure your safety.Arrange an immediate boiler 
    service.
    If set to do so, it may be 
    possible to obtain limited use 
    of the boiler by pressing any 
    EXTRA HOUR button. Each 
    button press will allow operation 
    of the boiler for 1 hour at a time, 
    and the screen will display the 
    message ‘On 1h’.
    After servicing your boiler, the 
    Service Engineer / Installer will 
    reset the ST9520C to remind 
    you when the next boiler service 
    is due. Each service is normally 
    a maximum of 1 year apart.
    ST9520C shows the 
    message ‘SENSOR LOW 
    BATT’ and a flashing radiator 
    symbol 
    Your DT92E 
    batteries are 
    running low on 
    power. Change the DT92E batteries for 
    the indicated zone thermostat 
    (see page 21 for how to do 
    this).
    DT92E shows a flashing 
    battery symbol 
    DT92E display is blank
    FAQ  AND TROUBLESHOOTING 
    						
    							30
    SymptomPossible CauseRemedy
    ST9520C shows the 
    message ‘NO SIGNAL’ and 
    a flashing radiator symbol 
     for one of the zones
    DT92E shows a flashing RF 
    symbol 
    Your DT92E 
    batteries are 
    running low on 
    power. Change the DT92E batteries 
    (see page 21 for how to do this).
    RF communication 
    path between 
    ST9520C and 
    DT92E is blocked, 
    possibly by a metal 
    object. Check direct path between both 
    products and re-position any 
    objects that may be blocking 
    the signal.
    Relocate the DT92E, if possible.
    ST9520C shows the 
    message ‘NO SIGNAL’ and 
    a flashing flame symbol 
     
    Red light on BDR91T (if 
    installed) is lit continuously.  RF communication 
    path between 
    ST9520C and 
    BDR91T is blocked, 
    possibly by a metal 
    object.Check direct path between both 
    product and re-position any 
    objects that may be blocking 
    the signal.
    ST9520C shows the 
    message ‘SENSOR FAULT’ 
    and a flashing radiator 
    symbol 
    DT92E display shows ‘’ and a flashing spanner 
    symbol   Fault with DT92E
    Call Installer
    ST9520C shows the message 
    ‘OPENTHERM FAULT’ Fault with the 
    Opentherm boiler.Enter Enquiry Mode as 
    described on page 14, use 
    the 
     or  buttons to scroll 
    round to a display that says 
    ‘OPENTHERM’.
    A fault code may be shown on 
    the main display. Refer to the 
    Boiler manufacturer’s instructions 
    for the required action.
    If the display shows -- -- this 
    means there is a break in the 
    OpenTherm wiring between the 
    ST9520C and the boiler.
    If in doubt, call your Installer.
    The Opentherm 
    wiring is broken or 
    disconnected.
    or
    Opentherm has 
    been configured but 
    the wiring has not 
    been connected.
    FAQ  AND TROUBLESHOOTING 
    						
    All Honeywell manuals Comments (0)

    Related Manuals for Honeywell Sundial RF Pack 5 Wireless Enabled 2 Zone Programmer and Thermostats User Manual